Numerical VT Protection Control and Monitoring Device NR-500PT2

Numerical VT Protection Control and Monitoring Device NR-500PT2

Custom-engineered Numerical VT Protection Control and Monitoring Device for 110kV-and-below substation bus sections, tailored to your grid code and panel layout.
Send Inquiry
Description

NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of numerical vt protection control and monitoring device nr-500pt2 in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.

 

Overview

 

 

NH34-2

 

The NR-500PT2 watches over the voltage transformer (VT/PT) of one bus section. It reads the bus voltage continuously, protects the section against abnormal voltage, and reports what it sees to your substation automation system.

It is built for 110kV-and-below systems that are ungrounded or grounded through an arc-suppression coil. In these networks a single-phase earth fault does not trip the line right away. Operators need reliable voltage and insulation data to know it has happened. The NR-500PT2 supplies that data for one bus section, with overvoltage and undervoltage protection, bus insulation monitoring, VT-wire-break self-checking and fault recording in a single unit.

 

It serves as one subsystem of a substation automation scheme. If you need to supervise two bus sections and parallel their VT secondary circuits, the sister model NR-500PT1 covers that job. The NR-500PT2 is the right choice when each bus section gets its own dedicated protection and monitoring unit.

We build it in our own factory in Yueqing, Zhejiang. Rated values and digital I/O are set to your order before we make the hardware.

product-1200-900

 

 

Key Features & Protection Functions

  • product-1200-800

    Voltage protection

    • Overvoltage protection

    • Undervoltage protection

  • product-5712-4284

    Bus and VT supervision

    • Bus insulation monitoring for earth-fault awareness on ungrounded or arc-suppression-coil-grounded systems
    • VT wire-break self-checking, so a lost voltage signal is flagged rather than mistaken for a real undervoltage condition

     

    Recording and monitoring

    • Fault recording for post-event analysis

    • Voltage measurement on three phases plus zero-sequence voltage (U0)

  • product-1200-900

    Hardware and communication

    • 16 digital inputs and 10 dry-contact outputs
    • One RS-485 port as standard, with options for two RS-485 ports or two Ethernet ports

    • AC/DC110V, AC/DC220V or DC48V auxiliary supply

    • Rated and digital I/O customization, confirmed before manufacture

 

 

Technical Specifications

 

Parameter

NR-500PT2

Device type

Numerical VT protection control and monitoring device

Monitored object

VT of one bus section

System voltage level

110kV and below

System grounding

Ungrounded or arc-suppression-coil grounded

Voltage measurement channels

3 phases + U0

Digital inputs

16

Digital outputs

10 dry contacts

Communication ports

1 × RS-485 standard; optional 2 × RS-485 or 2 × Ethernet

Protection and supervision functions

Overvoltage; undervoltage; bus insulation monitoring; VT wire-break self-check; fault recording

Auxiliary power supply

AC/DC110V, AC/DC220V or DC48V

Rated voltage

100V; 400V (customized)

Rated frequency

50Hz

Operating temperature

-30°C to +55°C

Relative humidity

≤95%, no condensation

Atmospheric pressure

80kPa to 110kPa

Site conditions

No acid or alkali corrosive gas, no explosive substances; lightning, rain and snow protection in place

Front panel

156 mm × 232 mm

Depth

198 mm overall, 171 mm body

Rear view

136 mm × 210 mm

Panel cut-out

138 mm × 212 mm (−1 mm tolerance)

Minimum order quantity

10 units

Warranty

2 years, counted from arrival of goods

 

Applications

 

 

product-1264-711
  • Substations
    Put one NR-500PT2 on each bus section of a 110kV, 66kV, 35kV or 10kV substation. You get dedicated bus voltage supervision and insulation monitoring feeding your automation system.

  • Hydropower
    Generator-side and step-up buses in small and medium hydropower stations need dependable voltage supervision. The device adds protection and recording without bringing a separate monitoring box.

product-1672-940
  • Distributed PV
    Commercial and industrial PV plants usually connect at 35kV or 10kV. A VT unit on the collection bus tracks voltage and flags abnormal conditions.

  • Industrial & Mining
    Mines, steel plants, chemical plants and cement works run 35kV and 10kV distribution rooms where an earth fault on an ungrounded bus must be noticed quickly.

product-1246-701
  • Rail & Transportation
    Traction and auxiliary power supply substations along rail lines and highways need steady bus voltage data for remote supervision.

 

 

How It Works

 

 

Signal Acquisition

The bus VT secondary signals (three phases plus U0) come into the device. It also reads 16 digital inputs, such as breaker and isolator positions.

Protection Logic

The device compares the measured voltages with the settings for overvoltage, undervoltage and insulation monitoring. It also checks the VT circuit itself for a broken wire.

Fault Judgment

If a protection condition is met, the device raises an alarm or operates its outputs. If the VT circuit is faulty, it reports the fault as a VT problem and not as a genuine voltage drop.

Output And Recording

The 10 dry-contact outputs act on your scheme. Fault records are stored, and measurements and events go to the substation system over RS-485 or Ethernet.

 

 

Why Choose NAHO: Custom Engineering Capability

 

product-1267-1027

A standard relay forces you to design your panel around it. We do it the other way round. Here is what we commit to, and what stands behind each point.

  • We have customized for many different sites. We have delivered tailored solutions for 144+ projects across substations, mines, steel plants, chemical works, transport facilities and distributed PV. No two of them were identical.

  • We cover your voltage level. Our project record spans 110kV, 66kV, 35kV and 10kV, and one device family suits all of them.

  • We customize the parameters that matter. Rated values and digital I/O can be specified to your order. You tell us before ordering, and we build the hardware to match. Because this is done in hardware, we ask you to confirm the details at order stage, as they cannot be changed from the front panel later.

  • We have 30+ years of experience. The company grew from a 1992 start in Yueqing's electrical hub into a specialist in power automation and relay protection.

  • We take part in writing the standards. We have helped draft national and energy-industry standards, including the 35kV-and-below standardized protection device requirements and NB/T 11054-2023.

  • We test every unit in-house. Each device goes through SMT assembly with AOI inspection, program burning, a 72-hour aging run on 24V, 48V or 220V supply, a withstand voltage test, a short-circuit check and final factory inspection before shipment.

  • We offer OEM/ODM. Appearance customization is available for large orders, because the mold investment calls for volume. We also support project integration, technical support and after-sales service.

 

 

Certifications & Standards

 

product-1221-1628
product-1268-1711
product-1267-1710
product-1268-1711
  • ISO 9001 quality management system certification
  • CCC certification
  • CE certification
  • IEC 60255 / IEC 61850 related type test reports
  • KETOP laboratory type test reports (National Relay Protection and Automation Equipment Quality Inspection and Testing Center)
  • State Grid qualified supplier (since 2018)
  • National high-tech enterprise, and a national-level "Specialized, Refined, Distinctive and Innovative" enterprise (2023)
  • 70+ patents and software copyrights
  • Standards participation:

     ○ General technical requirements for 35kV-and-below standardized protection devices (national standard)

     ○ NB/T 11054-2023, Technical Specification for Anti-islanding Protection Devices

      ○ NB/T 11483-2024, Technical Specification for Relay Protection of Urban Rail Transit AC Power Supply Systems

      ○ NB/T 11480-2024, Technical Specification for Environmental Control Systems of Outdoor Control Cabinets in Smart Substations

All our products have passed KETOP laboratory type tests and IEC-TC95 international standard testing.

 

 

Project References

 

product-1200-1600

Our delivery record covers every level from 110kV to 10kV, across many provinces and industries. Examples:

  • 110kV: Gansu Zhangye Shandan cement plant substation; Xinjiang Kashgar construction substation; Chongqing Ganshui capacity-increase power project
  • 66kV: Jilin Yanji heating plant 66kV distribution; Jilin Haigou gold mine 66kV distribution room renovation
  • 35kV: Hohhot and Baotou substations in Inner Mongolia; Shanxi Datong coal mine substations; Xinjiang Hami highway toll station distribution; Qinghai Golmud salt lake substation
  • 35kV PV: Ningbo and Cixi 35kV grid-connected PV projects, including a 15.6MW distributed PV project
  • 10kV: Qinghai Xining Haihu New District air-defense project distribution; Sichuan Panzhihua coal mine substation; Shanxi Taiyuan Jinqiu foundry substation
  • Landmark projects: Power supply protection for the opening ceremony venue of the 2010 16th Asian Games (Haixinsha); Three Gorges Yunyang reservoir area project; Inner Mongolia wind farm

 

 

FAQ

 

Q1: What is a Numerical VT Protection Control and Monitoring Device?

It is a numerical relay that monitors the voltage transformer of a bus section. It measures bus voltage, protects against overvoltage and undervoltage, monitors insulation, checks the VT circuit for wire breaks, and records faults. The NR-500PT2 does all of this for one bus section.

Q2: Where is a VT Protection Control and Monitoring Device used?

It is used in 110kV-and-below substations, hydropower stations, distributed PV plants, industrial and mining distribution rooms, and rail and transport power supply systems. It suits systems that are ungrounded or arc-suppression-coil grounded.

Q3: Can this device be used for ungrounded or arc-suppression-coil-grounded systems?

Yes. That is its design scope. Its bus insulation monitoring function helps the operator notice earth faults in such systems.

Q4: What protection functions does the NR-500PT2 provide?

It provides overvoltage protection, undervoltage protection, bus insulation monitoring, VT wire-break self-checking and fault recording.

Q5: Can digital I/O and rated values be customized?

Yes. Rated values and digital I/O are customized to your requirements. Please state them before ordering and note them on the order. We configure the hardware at the factory, and it cannot be reconfigured by the customer afterwards.

Q6: What is the difference between the NR-500PT1 and NR-500PT2?

The NR-500PT1 monitors two bus sections and handles automatic and manual VT paralleling. The NR-500PT2 protects and monitors the VT of a single bus section.

Q7: What information do you need for a quote?

Please tell us the system voltage level and grounding method, the rated voltage (100V standard, 400V custom), the auxiliary supply (AC/DC110V, AC/DC220V or DC48V), the digital I/O you need, the communication ports (RS-485 or Ethernet), the quantity and your destination country. A panel drawing or single-line diagram helps us a great deal.

Q8: Do you provide OEM/ODM customization?

Yes. We offer OEM and ODM services, project integration, technical support and after-sales service. Appearance customization is accepted for large orders because of the mold development cost.

Q9: What is the minimum order quantity and warranty?

The minimum order is 10 units. The warranty is 2 years from the date the goods arrive.

Q10: Can you provide technical drawings, wiring diagrams and testing support?

Our engineers provide technical support for selection, installation and commissioning. Send us your panel model and requirements with your inquiry, and we will tell you which drawings and documents we can supply.

 

Get a Quote

 

product-1269-952

Need a Numerical VT Protection Control and Monitoring Device built around your panel?

Send us your voltage level, grounding method, rated values and I/O needs. Our engineers will confirm the configuration and come back with a quotation.

Request a Quote for NR-500PT2

Phone: 8615057501111

WhatsApp / Telegram: 86 13868721792">86 13868721792

Email: Dr502963156@gmail.com

Address: No. 15 Zhengtai Road, Xinguang Industrial Zone, Liushi, Yueqing, Zhejiang, China

Get a Quote

 

Hot Tags: numerical vt protection control and monitoring device nr-500pt2, China numerical vt protection control and monitoring device nr-500pt2 manufacturers, suppliers, factory