Overcurrent Protection Of Transformer NR-310H/V

Title Tag
Overcurrent Protection of Transformer | NR-310H/V | NAHO
Meta Description
NAHO NR-310H/V transformer overcurrent protection relay for 10kV & below. Inrush blocking, 3 inverse curves, Modbus/101/103. Get a quote in 24h.
Overcurrent Protection of Transformer: NR-310H/V Microcomputer Protection Relay
Overcurrent back-up protection relay for transformer incoming and outgoing circuits on 10kV and below systems, with inrush blocking and customizable I/O.
Send Inquiry
Description

NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of overcurrent protection of transformer nr-310h/v in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.

 

Introduction

 

NR-310H
1-NH-310V

The NR-310H/V is a microcomputer-based protection and monitoring relay designed for overcurrent protection of transformer circuits in small-current grounding systems rated 10kV and below. Installed on the incoming or outgoing side of a transformer, it acts as the back-up protection against phase-to-phase short circuits, ground faults and overloads, and trips the breaker before the fault spreads to the transformer and the rest of the switchgear.

 

The relay does not replace differential protection. It covers the overcurrent layer that every transformer circuit needs, and it is built to cope with transformer-specific conditions: magnetizing inrush blocking prevents false trips at energization, three inverse-time curves let you coordinate with upstream and downstream devices, and non-electric quantity inputs let transformer body signals trip or alarm through the same relay.

It is used on distribution transformers, dry-type transformers, oil-immersed transformers, station service transformers and box-type (pad-mounted) substations. The NR-310H/V is available in standard and customized configurations. The series also includes NR-311H/V (dual-incoming protection and auto-switching), NR-312H/V (section-switch protection and auto-switching) and NR-313H/V (PT cabinet monitoring and protection group), and comes in horizontal (H) and vertical (V) enclosure formats to fit different panel layouts.

product-1200-900

 

 

Key Features & Protection Functions

 

  • product-1200-800

    Transformer Overcurrent Protection

    • Three-section overcurrent protection with directional and composite-voltage blocking
    • Magnetizing inrush blocking to avoid false trips when the transformer is energized

    • Inverse time-limit overcurrent with three selectable curves: standard inverse, very inverse and extremely inverse

    • Overload protection (alarm or trip)

    • Negative-sequence overcurrent protection

    • High-current trip blocking

    • Overcurrent post-acceleration

  • product-5712-4284

    Ground Fault & Voltage Protection

    • Three-section zero-sequence overcurrent protection
    • Zero-sequence inverse time-limit overcurrent

    • Zero-sequence overcurrent post-acceleration

    • Over/low-voltage protection (alarm or trip)

    • Zero-sequence overvoltage (alarm or trip)

     

    Transformer Body Signals

    • Non-electric quantity protection: transformer gas, temperature and pressure-relief signals can be connected to trip or alarm
    • 10-way digital input (customizable) and 4-way digital output (dry contacts)

  • product-1265-949

    Measurement & Communication

    • 3-phase + I0 current protection/measurement channel

    • 3-phase + U0 voltage measurement channel

    • RS-485 port with Modbus, IEC 60870-5-101 and IEC 60870-5-103 protocols

     

    Reclosing is also available on the platform for feeder applications, but it is normally not used on transformer circuits.

 

 

Technical Specifications

 

Parameter

Specification

Applicable Scope

Small-current grounding systems, 10kV and below; overcurrent protection of transformer incoming/outgoing circuits

Rated Voltage

100V

Rated Frequency

50Hz

Rated Current

5A, 1A (customized)

Auxiliary Power Supply

AC/DC 85V–265V; DC 48V; DC 24V

Current Protection/Measurement Channel

3-phase + I0

Voltage Measurement Channel

3-phase + U0

Overcurrent Protection

Three-section, with directional and composite-voltage blocking

Inverse-Time Curves

3 curves (standard, very, extremely inverse)

Inrush Blocking

Yes

Non-Electric Quantity Protection

Yes

Digital Input

10-way (customizable)

Digital Output

4-way dry contacts

Communication Port

RS-485

Communication Protocol

Modbus / 101 / 103

Operating Temperature

-30℃ ~ +55℃

Relative Humidity

≤95%, non-condensing

Atmospheric Pressure

80–110kPa

Test Standard Atmospheric Condition

15℃–35℃, 45%–75% RH, 86–106kPa

Dimensions (NR-310H)

157mm (W) × 74mm (H) × 110mm (D)

Panel Cutout (NR-310H)

146 ± 0.2mm (W) × 69.8 ± 0.2mm (H)

Dimensions (NR-310V)

74mm (W) × 157mm (H) × 110mm (D)

Panel Cutout (NR-310V)

69.8 ± 0.2mm (W) × 146 ± 0.2mm (H)

Compliance

Type-tested at KETOP Laboratory; IEC-TC95 international standard testing

 

Environment: the surrounding air must be free of conductive, corrosive or explosive substances, and the installation site must be protected from rain and snow.

 

Applications

 

 

modular-1

Transformer incoming cabinets (10kV side)

  • Back-up overcurrent and ground-fault protection at the incoming side of distribution, dry-type, oil-immersed and box-type transformers.
modular-2

Industrial distribution transformer circuits

  • Protection of transformer circuits in mines, steel plants and chemical plants, where load changes are frequent and short-circuit protection must stay selective.
modular-3

Station service and distribution transformer circuits

  • Overcurrent and overload protection for station service transformers and distribution transformers in substations and distribution rooms.

 

 

How It Works

 

Signal Acquisition

Three-phase currents, zero-sequence current and voltage signals are sampled from the CT and PT circuits of the transformer.

Protection Logic

The microprocessor compares the signals with the set overcurrent, zero-sequence and voltage thresholds. Inrush blocking recognizes magnetizing inrush at energization.

Fault Judgment

For a real fault, the relay decides the trip stage according to the definite-time or selected inverse-time curve. Non-electric signals from the transformer body are processed in parallel.

Trip And Report

The relay issues the trip command through its dry-contact outputs and reports status over RS-485 (Modbus/101/103) to your SCADA.

 

 

Why Choose NAHO: Custom Engineering Capability

 

product-1267-1027

Built Around Your Project, Not Our Catalog

 
  • 30+ years of power automation experience. Our history goes back to 1992, and we have delivered custom solutions for 144+ projects from 110kV down to 10kV, across more than 11 provinces in substations, mines, steel plants, chemical plants and photovoltaic projects.
  • Customizable on the NR-310H/V. Digital input channels are user-definable. Rated current can be customized to 5A or 1A to match your CT. Horizontal (H) or vertical (V) installation fits your panel layout.

  • OEM/ODM, project integration, technical support and after-sales service.

  • Custom enclosure and panel design for volume orders. Tooling investment is justified once your order volume supports it.

  • Tested before it ships. Each unit goes through SMT with AOI inspection, a 72-hour burn-in on 24V/48V/220V power, withstand-voltage and short-circuit testing, and a final factory inspection.

 

Certifications & Standards

 

product-1221-1628
product-1268-1711
product-1267-1710
product-1268-1711
  • Type-tested at the National Relay Protection & Automation Equipment Quality Inspection and Testing Center (KETOP Laboratory)
  • Passed IEC-TC95 international standard testing
  • Contributor to the drafting of national and energy-industry standards, including NB/T 11054-2023 (anti-islanding protection), NB/T 11483-2024 (relay protection for urban rail AC power supply) and NB/T 11480-2024 (outdoor control cabinet environment control for smart substations)
  • State Grid qualified supplier
  • National High-Tech Enterprise; National "Specialized, Refined, Distinctive and Innovative" enterprise
  • 70+ patents and software copyrights

 

 

Case Studies / Project References

 

 

product-1200-1600

Featured projects

  • Power supply protection and distribution for the opening ceremony of the 16th Asian Games (Haixinsha Square, 2010)
  • Three Gorges Yunyang reservoir area project

 

Selected references (project names withheld, pending permission)

 

Industry

Voltage Level

Region

Cement plant substation

110kV

Gansu

Coking plant waste-heat power generation

66kV

Shanxi

Gold mine distribution room renovation

66kV

Jilin

Aluminum manufacturing

35kV

Shandong

Chemical plant substation

35kV

Shandong

Iron ore mine substation

35kV

Hebei

Data center distribution room

35kV

Inner Mongolia

Tobacco logistics center

35kV

Guizhou

Coal mine substation

35kV/6kV

Shanxi

Distributed PV project (15.6MW)

35kV

Zhejiang

Textile factory substation

35kV

Xinjiang

Coal mine substation

10kV

Sichuan

 

FAQ

 

Q1: What is overcurrent protection of a transformer?

It is the protection that detects short-circuit and overload currents flowing through a transformer circuit and trips the breaker. It is used as back-up protection on the incoming or outgoing side of the transformer.

Q2: Where is the NR-310H/V used?

On incoming and outgoing circuits of distribution, dry-type, oil-immersed, station service and box-type transformers in 10kV and below small-current grounding systems.

Q3: Does the NR-310H/V replace transformer differential protection?

No. It provides overcurrent back-up protection. Differential protection is a separate function.

Q4: How does it handle transformer inrush current?

It has magnetizing inrush blocking, which prevents false trips when the transformer is energized.

Q5: What protection functions does the NR-310H/V provide?

Three-section overcurrent with directional and composite-voltage blocking, negative-sequence overcurrent, inverse time-limit overcurrent, overload, three-section zero-sequence overcurrent, over/low-voltage and zero-sequence overvoltage protection, plus non-electric quantity protection.

Q6: Which inverse-time curves are supported?

Three curves: standard inverse, very inverse and extremely inverse.

Q7: Can transformer gas, temperature or pressure-relief signals be connected?

Yes. The non-electric quantity protection accepts transformer body signals for trip or alarm.

Q8: Can the digital I/O or rated current be customized?

Yes. Digital input channels can be user-defined, and rated current can be customized

Q9: Do you provide OEM/ODM customization?

Yes. We offer OEM/ODM, project integration, technical support and after-sales service. Custom enclosures are available for volume orders.

Q10: What is the warranty?

Two years, counted from the delivery date.

Q11: Can you provide technical drawings, wiring diagrams and testing support?

Yes. Send us your project details and we will provide the documents and technical support you need.

 

Get a Quote

 

product-1269-952

Send us the following and we will reply within 24 hours:

  • Project name and location
  • System voltage and frequency
  • Transformer type (distribution / dry-type / oil-immersed / station service / box-type)
  • Protected side (incoming or outgoing)
  • Required protection functions
  • Communication protocol needs
  • Quantity
  • Customization requirements (digital I/O, rated current, H/V format, enclosure)

 

Request a Quote

 

Hot Tags: overcurrent protection of transformer nr-310h/v, China overcurrent protection of transformer nr-310h/v manufacturers, suppliers, factory