Transformer Main and Backup Protection Relay NR-500TD

Transformer Main and Backup Protection Relay NR-500TD

Factory-direct transformer differential main protection, multi-side backup protection and non-electric protection for substations up to 110kV. Rated voltage and current can be customized.
Send Inquiry
Description

NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of transformer main and backup protection relay nr-500td in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.

 

Overview

 

 

NH37-2

 

NAHO is a manufacturer of power automation and microcomputer protection devices, based in Yueqing, Zhejiang, China. We design, produce and test the NR-500T series in our own factory. The series is a range of transformer main and backup protection relays for substation relay protection systems rated up to 110kV. The NR-500TD main protection relays serve as the primary protection for power transformers. The NR-500TB backup protection and measurement relays serve as backup protection on the transformer's various sides. Configured together, the two series cover the protection, measurement, control and telecontrol communication requirements of a main transformer.

 

The series is organized by role and winding configuration:

  • NR-500TD3: differential main protection for three-winding transformers
  • NR-500TD2: differential main protection for two-winding transformers
  • NR-500TB1: backup protection for the 110kV side of the main transformer
  • NR-500TB2: backup protection and measurement for the 35kV side of the main transformer
  • NR-500TB3: backup protection for the medium- and low-voltage sides of the main transformer
  • NR-500TN: non-electric protection, measurement and oil temperature measurement

Rated voltage, rated current and communication configuration can be customized to match your CT/PT setup and SCADA requirements. You can specify a single relay or a complete main-and-backup set.

product-5712-3213

 

 

Models in the NR-500T Series

 

 

Model

Role

Application

NR-500TD3

Main protection

Three-winding transformer differential protection

NR-500TD2

Main protection

Two-winding transformer differential protection

NR-500TB1

Backup protection

110kV side of the main transformer

NR-500TB2

Backup protection & measurement

35kV side of the main transformer

NR-500TB3

Backup protection

Medium- and low-voltage sides of the main transformer

NR-500TN

Non-electric protection & measurement

Non-electric protection and oil temperature measurement

 

 

Key Features & Protection Functions

 

  • product-1200-800

    Main Protection Functions (NR-500TD3 / NR-500TD2)

    • Differential instantaneous protection
    • Ratio-restraint differential protection

    • Harmonic-restraint differential protection

    • CT break blocking for differential protection

    • Differential current over-limit alarm

    • Y/D-11 and Y/D-01 conversion

    • Non-electric protection, 7 channels

    • Fault recording

  • product-5712-4284

    Backup Protection Functions (NR-500TB1 / TB2 / TB3)

    • Time-limited instantaneous overcurrent protection (TB1, TB2, TB3)
    • Complex-voltage blocking directional overcurrent, 2 time limits (TB1, TB2, TB3)

    • Zero-voltage blocking directional zero-sequence overcurrent, 2 time limits (TB1)

    • Gap overcurrent protection (TB1)

    • Zero-sequence overvoltage protection (TB1)

    • Overload protection (TB1, TB2, TB3)

    • Busbar grounding alarm (TB2, TB3)

    • Complex-voltage start of the high-voltage side (TB3)

    • Fault recording

     

    Self-Supervision & Control Functions (TB series)

    • PT break self-check
    • PT loss self-check

    • CT break self-check

    • Operation circuit self-check

    • Operation box (TB2, TB3)

  • product-1265-949

    Non-Electric Protection (NR-500TN)

    • 16-channel non-electric protection

    • 2-channel 4–20mA DC transmitter signal acquisition

    • Fault recording

     

    Measurement & Communication

    • Current and voltage measurement channels, configured per model (see the table below)

    • Standard 1 RS-485 port; optional 2 RS-485 ports and 2 Ethernet ports

 

 

Configuration Comparison by Model

 

 

Item

TD3

TD2

TB1

TB2

TB3

TN

Current channels

9-phase current

6-phase current

6-phase + I0 + Ij0

6-phase + I0

6-phase + I0

2 × 4–20mA

Voltage channels

–

–

3-phase + U0

3-phase + U0

3-phase + U0

–

Digital inputs

16

16

16

16

16

16

Digital outputs

10

10

14

14

14

10

Non-electric protection

7 channels

7 channels

–

–

–

16 channels

Fault recording

✓

✓

✓

✓

✓

✓

 

 

Technical Specifications

 

Parameter

Specification

Applicable Scope

Transformer main and backup protection in substation relay protection systems, up to 110kV

Auxiliary Power Supply

AC/DC 110V or AC/DC 220V; DC 48V

Rated Voltage

100V; 400V (customized)

Rated Frequency

50Hz

Rated Current

5A; 1A (customized)

DC Transmitter Signal Input

4–20mA

Digital Input

16 channels

Digital Output

10 channels (TD, TN); 14 channels (TB)

Communication Port

Standard 1 × RS-485; optional 2 × RS-485 and 2 × Ethernet

Operating Temperature

-30℃ ~ +55℃

Relative Humidity

≤95%, non-condensing

Atmospheric Pressure

80–110kPa

Test Standard Atmospheric Condition

15℃ ~ 35℃, 45% ~ 75% RH, 86 ~ 106kPa

Dimensions

156mm (W) × 232mm (H) × 198mm (D)

Panel Cutout

138mm (W) × 212mm (H)

Type Testing

KETOP Laboratory type tests; IEC-TC95 international standard testing

 

Operating environment: The air around the device must be free of corrosive acids, alkalis and explosive substances. The device is designed with lightning, rain and snow protection in mind.

 

Applications

 

 

modular-1
  • Power transformer main protection
    NR-500TD3 and NR-500TD2 provide differential main protection for three-winding and two-winding transformers in substations up to 110kV.

  • Multi-side backup protection
    NR-500TB1, TB2 and TB3 provide backup protection for the 110kV, 35kV, and medium- and low-voltage sides of the main transformer.

modular-2
  • Non-electric protection and temperature measurement
    NR-500TN handles non-electric protection and oil temperature measurement as part of a complete transformer protection scheme.

modular-3
  • Industrial main step-down stations
    The series suits transformer protection in industrial plants such as mines, steel, chemicals and building projects.

 

 

How It Works

 

Signal Acquisition

The relay samples current from each transformer side. TB models also sample voltage and zero-sequence quantities.

Protection Logic

For differential protection, Y/D-11 and Y/D-01 conversion handles phase compensation. Ratio-restraint and harmonic-restraint criteria are then applied to the differential current. Backup models run overcurrent, voltage-blocking, zero-sequence and overload logic.

Fault Judgment

The relay combines its protection criteria with self-checks (CT break, PT break, PT loss and operation circuit) to separate real faults from abnormal conditions.

Trip Command And Recording

The relay issues trip or alarm outputs through its digital outputs and records the fault. Data is available over the RS-485 or Ethernet ports.

 

 

Why Choose NAHO: Factory-Direct and Built Around Your Project, Not Our Catalog

 

product-1267-1027

As the manufacturer, we control design, production and testing in one place. That is why we can adapt each relay to your CT ratio, auxiliary supply and panel layout.

 

  • Customizable electrical parameters. Rated voltage 100V or 400V; rated current 5A or 1A; auxiliary supply AC/DC 110V, AC/DC 220V or DC 48V.

  • Flexible communication configuration. Standard 1 RS-485, or optional 2 RS-485 plus 2 Ethernet ports.

  • Custom enclosure and panel design for volume orders. Enclosure tooling is a real investment, so we accept custom enclosures once your order volume supports it.

  • OEM/ODM, project integration, technical support and after-sales service. One supplier from selection to commissioning.

  • Proven range. 144+ delivered projects across 110kV, 66kV, 35kV and 10kV levels, in 11+ provinces, from substations and mines to distributed PV projects of up to 10.96606 MW.

  • Controlled production. SMT placement with AOI inspection, wave soldering, program burning, assembly, debugging, 72-hour aging, withstand voltage testing, short-circuit check and final factory inspection (including time synchronization within 2 seconds).

  • Manufacturing since 1992. More than 30 years of power automation experience.

  • Warranty. 2 years, counted from arrival.

 

Certifications & Standards

 

product-1221-1628
product-1268-1711
product-1267-1710
product-1268-1711
  • Type-tested at the national relay protection and automation equipment quality inspection centre (KETOP Laboratory)
  • IEC-TC95 international standard testing
  • National Grid qualified supplier (since 2018)
  • National high-tech enterprise
  • National-level "Specialized, Refined, Distinctive and Innovative" enterprise (2023)
  • 70+ patents and software copyrights
  • Participated in drafting the national standard for general technical requirements of relay protection devices for 35kV and below (2019 and 2021)
  • Participated in drafting NB/T 11054-2023, Technical Specification for Anti-islanding Protection Devices
  • Participated in drafting NB/T 11483-2024, Technical Specification for Relay Protection of AC Power Supply Systems in Urban Rail Transit
  • Participated in drafting NB/T 11480-2024, Technical Specification for Environmental Control Systems of Outdoor Control Cabinets in Smart Substations

 

Case Studies / Project References

 

 

These are company-level references covering our delivered substations and power distribution projects. They are not specific to the NR-500T models.

 

Project

Voltage Level

Industry

Zhangye Shandan cement plant 110kV substation, Gansu

110kV

Building materials

Jinta County 110kV substation, Jiuquan

110kV

Industrial power supply

Hashi construction-use 110kV substation, Xinjiang

110kV

Construction power

Ganshui Town capacity-expansion power project, Chongqing

110kV

Power distribution

Haigou gold mine 66kV distribution room renovation, Jilin

66kV

Mining

Yingkou carbon plant 66kV project, Liaoning

66kV

Industrial

Anshan industrial zone 66kV substation renovation, Liaoning

66kV

Industrial

Baotou Furong 35kV substation expansion, Inner Mongolia

35kV

Power distribution

Hebei Chengde iron mine 35kV substation

35kV

Mining / Steel

Shandong Heze Chengwu 35kV distribution room

35kV

Power supply

 

Featured projects: 

  • 2010 Asian Games, Haixinsha Square opening ceremony: protection and power distribution for the power supply system.

  • Three Gorges Yunyang reservoir area project.

 

 

FAQ

 

Q1: Are you a manufacturer or a trading company?

We are a manufacturer. NAHO (NRUICN) has been producing power automation and microcomputer protection devices in Yueqing, Zhejiang, China since 1992. The NR-500T series is designed, produced and tested in our own factory, so you buy direct from the source.

Q2: What is a transformer main and backup protection relay?

It is a microprocessor-based device that protects a power transformer. The main protection detects internal faults through differential protection. The backup protection provides overcurrent, voltage and zero-sequence protection on the transformer's various sides.

Q3: Where is the NR-500T series used?

It is used in substation relay protection systems up to 110kV, including utility substations and industrial main step-down stations.

Q4: Which model should I choose for a three-winding or a two-winding transformer?

Choose NR-500TD3 for a three-winding transformer and NR-500TD2 for a two-winding transformer. NR-500TD3 has 9-phase current inputs, and NR-500TD2 has 6-phase.

Q5: What protection functions does the NR-500TD provide?

It provides differential instantaneous protection, ratio-restraint differential protection and harmonic-restraint differential protection. It also provides CT break blocking, differential current over-limit alarm, Y/D-11 and Y/D-01 conversion, 7-channel non-electric protection and fault recording.

Q6: Which relay provides backup protection for each side of the main transformer?

NR-500TB1 covers the 110kV side, NR-500TB2 the 35kV side, and NR-500TB3 the medium- and low-voltage sides.

Q7: Can the rated voltage or rated current be customized?

Yes. Rated voltage is 100V, or 400V if customized. Rated current is 5A, or 1A if customized to your CT configuration.

Q8: What communication ports are available?

The standard configuration has 1 RS-485 port. An optional configuration adds 2 RS-485 ports and 2 Ethernet ports.

Q9: Does the series support non-electric protection?

Yes. The NR-500TD models include 7 non-electric protection channels, and the NR-500TN provides 16 channels plus 2-channel 4–20mA signal acquisition for oil temperature measurement.

Q10: What is the minimum order quantity?

The MOQ is 10 units.

Q11: Do you provide OEM/ODM customization?

Yes. We provide OEM/ODM customization, project integration, technical support and after-sales service. Custom enclosure design is available for volume orders.

Q12: What is the warranty period?

The warranty is 2 years, counted from the date of arrival.

 

Get a Quote

 

product-1269-952

Send us your project details and our factory engineering team will reply within 24 hours.

  • Project name & location
  • System voltage & frequency
  • Transformer type (two-winding / three-winding) and voltage levels
  • Required protection functions (main / backup / non-electric)
  • CT/PT ratings (rated current 5A or 1A; rated voltage 100V or 400V)
  • Auxiliary power supply (AC/DC 110V, AC/DC 220V or DC 48V)
  • Communication needs (RS-485 / Ethernet)
  • Quantity
  • Customization requirements

 

Request a Quote

 

Hot Tags: transformer main and backup protection relay nr-500td, China transformer main and backup protection relay nr-500td manufacturers, suppliers, factory