NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of transformer differential protection relay nr-500td2/td3 in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.
Overview

NAHO is a relay manufacturer with its own factory in Yueqing, Zhejiang, and over 30 years of experience in power automation. Every NR-500TD relay is built, tested and shipped from our own production lines. The NR-500TD2/TD3 is a transformer differential protection relay for substation relay protection systems at 110kV and below. It serves as the main protection of the power transformer. The NR-500TD2 protects two-winding transformers, and the NR-500TD3 protects three-winding transformers.
Differential protection detects internal transformer faults quickly and selectively. It does this with differential quick-break, ratio-restraint and harmonic-restraint elements, plus CT-failure blocking to avoid false operation. Both models also provide fault recording and 7-channel non-electric quantity protection.
The NR-500TD belongs to the NR-500T transformer protection series. Paired with the NR-500TB backup protection relays, it covers main protection, backup protection, measurement, control and telecontrol communication for a power transformer. The TD2/TD3 is available in standard and customized configurations (rated current, rated voltage, auxiliary supply), and we accept project-specific requests from the factory floor.

Key Features & Protection Functions
-

Protection Functions (Differential, ANSI 87T)
-
Differential quick-break protection
-
Ratio-restraint differential protection
-
Harmonic-restraint differential protection
-
CT-failure blocking of the differential element
-
Differential current over-limit alarm
-
Y/D-11 and Y/D-01 vector group conversion
-
Non-electric quantity protection, 7 channels
-
-

Measurement Functions
- NR-500TD3: 9-phase current protection/measurement channels (three windings)
-
NR-500TD2: 6-phase current protection/measurement channels (two windings)
Communication Functions
- 1 × RS-485 port as standard
-
Optional: 2 × RS-485 and 2 × Ethernet
-

Monitoring Functions
-
16 digital inputs
-
10 digital outputs
-
Fault recording
Model differences at a glance
-
NR-500TD3: main protection of three-winding transformers (9-phase current).
-
NR-500TD2: main protection of two-winding transformers (6-phase current).
-
Technical Specifications
|
Parameter |
Specification |
|
Applicable Scope |
Main protection of transformers in substations, 110kV and below |
|
Models |
NR-500TD3 (three-winding transformer); NR-500TD2 (two-winding transformer) |
|
Rated Voltage |
100V; 400V (customized) |
|
Rated Frequency |
50Hz |
|
Rated Current |
5A; 1A (customized) |
|
Auxiliary Power Supply |
AC/DC 110V or AC/DC 220V; DC 48V |
|
Current Protection/Measurement Channel |
NR-500TD3: 9-phase; NR-500TD2: 6-phase |
|
Digital Input |
16 channels |
|
Digital Output |
10 channels |
|
Non-electric Quantity Protection |
7 channels |
|
Communication Port |
1 × RS-485 standard; optional 2 × RS-485 and 2 × Ethernet |
|
Differential Functions |
Quick-break, ratio-restraint, harmonic-restraint, CT-failure blocking, differential over-limit alarm, Y/D-11 and Y/D-01 conversion |
|
Fault Recording |
Yes |
|
Operating Temperature |
-30℃ ~ +55℃ |
|
Relative Humidity |
≤95%, non-condensing |
|
Atmospheric Pressure |
80–110kPa |
|
Test Standard Atmospheric Condition |
15℃~35℃, 45%~75% RH, 86~106kPa |
|
Ambient Air |
Free of acid, corrosive or explosive substances; protected from lightning, rain and snow |
|
Compliance |
Type-tested by the KETOP Laboratory (National Relay Protection & Automation Equipment Quality Inspection Center); passed IEC-TC95 international standard testing |
Applications

-
Substation transformer main protection: two- and three-winding power transformers in substations at 110kV and below.

-
Complete transformer protection scheme: combine NR-500TD main protection with NR-500TB backup protection relays (110kV-side, 35kV-side, medium/low-voltage-side backup) and the NR-500TN non-electric quantity unit.

-
Industrial & mining power systems: main transformers in substations serving metallurgy, chemical, mining and other plants.
Selection tip: choose TD3 when the transformer has three windings, and TD2 when it has two.
How It Works
Signal Acquisition
The relay samples current from each winding side through 6 (TD2) or 9 (TD3) current channels.
Vector Group Compensation
Y/D-11 or Y/D-01 conversion aligns the winding currents of the transformer connection group.
Differential Judgment
The differential current is checked by quick-break, ratio-restraint and harmonic-restraint elements, with CT-failure blocking to prevent false operation.
Action And Record
The relay issues trip or alarm outputs, and records the fault waveform for analysis.
Why Choose NAHO: Built Around Your Project, Not Our Catalog

We are the factory, not a trading intermediary. That is why we can adapt a standard relay to your project.
-
30+ years in power automation. Our roots go back to 1992, and we have delivered custom solutions for 144+ projects across substations, hydropower, mining, PV and rail.
-
Customizable, verifiable parameters. Rated current 5A or 1A to match your CT; rated voltage 100V or 400V; auxiliary supply AC/DC 110V, AC/DC 220V or DC 48V.
-
Flexible communication. One RS-485 as standard, with optional dual RS-485 and dual Ethernet.
-
Custom enclosures at volume. We accept large-volume custom enclosure and panel design, because tooling investment is justified once order volume supports it.
-
OEM/ODM, project integration, technical support and after-sales from one factory.
-
Tested in our factory: SMT with AOI inspection, wave soldering, 72-hour burn-in, withstand-voltage and short-circuit testing, and final outgoing inspection.
-
Warranty: 2 years from the day of arrival.
-
MOQ: 10 units.
Certifications & Standards




- Type-tested by the KETOP Laboratory, the National Relay Protection and Automation Equipment Quality Inspection Center
- Passed IEC-TC95 international standard testing
- Drafting unit of national standards for 35kV and below standardized protection devices (participated in 2019 and 2021)
- Drafting participant of NB/T 11054-2023, NB/T 11483-2024 and NB/T 11480-2024 energy industry standards
- State Grid qualified supplier (since 2018)
- National High-tech Enterprise; National "Specialized, Refined, Distinctive and Innovative" enterprise (2023)
-
70+ patents and software copyrights
Project References
NAHO delivers protection and automation for substations from 110kV to 10kV. Selected company references:
|
Project (anonymized) |
Voltage Level |
Industry |
|
Food factory substation expansion, Zhengzhou |
110kV |
Industrial |
|
Construction-power substation, Kashgar, Xinjiang |
110kV |
Construction |
|
Cement plant substation, Zhangye, Gansu |
110kV |
Building materials |
|
County substation, Jiuquan, Gansu |
110kV |
Utility |
|
Capacity-increase power project, Chongqing |
110kV |
Utility |
|
Waste-heat power generation, Shanxi |
66kV |
Coking / power |
|
Heat-source plant main step-down, Yanji, Jilin |
66kV |
Heating |
|
Gold mine distribution room renovation, Jilin |
66kV |
Mining |
|
Transition substation, Kailu, Inner Mongolia |
66kV/10kV |
Utility |
|
Aluminum plant substation, Anhui |
35kV |
Metallurgy |
Featured projects:
-
Power supply protection and distribution for the opening ceremony venue (Haixinsha Square), 16th Asian Games, 2010
-
Three Gorges Yunyang reservoir area project
FAQ
Q1: What is a transformer differential protection relay?
It is a protection device that compares the currents entering and leaving a transformer. When the difference indicates an internal fault, it trips quickly. The NR-500TD2/TD3 is NAHO's main-protection relay for power transformers.
Q2: Where is the NR-500TD2/TD3 used?
In substation relay protection systems at 110kV and below, as the main protection of power transformers.
Q3: What is the difference between TD2 and TD3?
TD2 protects two-winding transformers with 6-phase current inputs. TD3 protects three-winding transformers with 9-phase current inputs.
Q4: What protection functions does it provide?
Differential quick-break, ratio-restraint differential, harmonic-restraint differential, CT-failure blocking, differential current over-limit alarm, Y/D-11 and Y/D-01 conversion, 7-channel non-electric quantity protection and fault recording.
Q5: Can the rated current, voltage or supply be customized?
Yes. Rated current can be 5A or 1A, rated voltage 100V or 400V, and auxiliary supply AC/DC 110V, AC/DC 220V or DC 48V.
Q6: What communication ports are available?
One RS-485 port as standard. Dual RS-485 and dual Ethernet are optional.
Q7: Do you provide OEM/ODM customization?
Yes. As the manufacturer, we provide OEM/ODM, project integration, technical support and after-sales service. Custom enclosures are accepted for large-volume orders.
Q8: What is the MOQ and warranty?
MOQ is 10 units. Warranty is 2 years from the day the goods arrive.
Q9: Can it be combined with backup protection?
Yes. Pair it with the NR-500TB1/TB2/TB3 backup protection relays and the NR-500TN non-electric quantity unit for a complete transformer protection scheme.
Q10: What information do you need for a quote?
See the list below.
Get a Quote (page end + sticky button)

Send us the following and our factory team replies within 24 hours:
- Project name & location
- Transformer type (two-winding or three-winding) and voltage level
- System voltage & frequency
- Rated current (5A / 1A) and rated voltage (100V / 400V)
- Auxiliary supply (AC/DC 110V / AC/DC 220V / DC 48V)
- Communication needs (RS-485 / Ethernet)
- Quantity
- Customization requirements
Hot Tags: transformer differential protection relay nr-500td2/td3, China transformer differential protection relay nr-500td2/td3 manufacturers, suppliers, factory