NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of transformer backup protection relay nr-500tb1 in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.
Overview

NAHO is the manufacturer of the NR-500TB1, and every unit is designed, assembled, aged and tested at our own factory in Yueqing, Zhejiang. The NR-500TB1 is a digital transformer backup protection relay for the high-voltage (110kV) side of a main transformer. It is intended for substation relay protection systems rated 110kV and below.
On the transformer's HV side, the relay supplies the backup protection that works behind the main protection. It combines time-limit overcurrent, voltage-blocked directional overcurrent, zero-sequence protection and gap protection in one unit. Faults that the main protection does not clear are isolated by the backup stage, so they do not spread to the rest of the network.
The NR-500TB1 belongs to the NR-500TB backup protection family. It is paired with the NR-500TD differential relays, which provide the main protection. Within the family, the TB2 covers the 35kV side and the TB3 covers the medium and low-voltage sides. The NR-500TB1 is available in standard and fully customized configurations, so current rating, voltage rating, auxiliary supply and communication ports can be matched to your project.

Key Features & Protection Functions
-

Protection Functions
-
Time-limit instantaneous overcurrent protection (ANSI 50/51)
-
Complex-voltage-blocked directional overcurrent protection, 2 time limits (ANSI 67 / 51V)
-
Zero-sequence-voltage-blocked directional zero-sequence overcurrent protection, 2 time limits (ANSI 67N)
-
Gap overcurrent protection (ANSI 50N/51N, gap zero-sequence current)
-
Zero-sequence overvoltage protection (ANSI 59N)
-
Overload protection (ANSI 49)
-
-

Measurement Functions
- 6-phase current channels plus I0 and Ij0 (gap zero-sequence current) input
-
3-phase voltage channels plus U0 input
-
Rated current 5A or 1A (customizable); rated voltage 100V (400V customizable)
Communication Functions
- 1 RS-485 port as standard
-
Optional configuration: 2 RS-485 ports and 2 Ethernet ports
-

Monitoring & Self-Supervision Functions
-
16 digital inputs and 14 digital outputs
-
PT disconnection self-check (ANSI 60)
-
PT voltage-loss self-check (ANSI 60)
-
CT disconnection self-check (ANSI 60CTS)
-
Operation circuit self-check (ANSI 74)
-
Fault recording
Where the NR-500TB1 sits in the family
The NR-500TB1 is the backup relay for the 110kV side of the main transformer. For the 35kV side, see the NR-500TB2. For the medium and low-voltage sides, see the NR-500TB3. For main protection of two-winding or three-winding transformers, see the NR-500TD2 and NR-500TD3. For non-electrical quantity protection, see the NR-500TN.
-
Technical Specifications
|
Parameter |
Specification |
|
Applicable Scope |
HV-side backup protection of main transformers in substations of 110kV and below |
|
Rated Voltage |
100V; 400V (customizable) |
|
Rated Frequency |
50Hz |
|
Rated Current |
5A; 1A (customizable) |
|
Auxiliary Power Supply |
AC/DC 110V or AC/DC 220V; DC 48V |
|
Current Protection/Measurement Channel |
6-phase + I0 + Ij0 |
|
Voltage Measurement Channel |
3-phase + U0 |
|
Digital Input |
16 channels |
|
Digital Output |
14 channels |
|
Communication Port |
1 × RS-485 as standard; optional 2 × RS-485 and 2 × Ethernet |
|
Protection Functions |
Time-limit instantaneous overcurrent (50/51); voltage-blocked directional overcurrent (67/51V); voltage-blocked directional zero-sequence overcurrent (67N); gap overcurrent (50N/51N); zero-sequence overvoltage (59N); overload (49) |
|
Self-Supervision |
PT disconnection, PT voltage loss, CT disconnection, operation circuit |
|
Fault Recording |
Yes |
|
Operating Temperature |
-30℃ ~ +55℃ |
|
Relative Humidity |
≤95%, non-condensing |
|
Atmospheric Pressure |
80–110kPa |
|
Test Standard Atmospheric Condition |
15℃~35℃, 45%~75% RH, 86~106kPa |
|
Ambient Conditions |
The surrounding air must be free of acid, alkali or explosive substances, and the site must be protected against lightning, rain and snow |
|
Compliance |
Type-tested at the KETOP Laboratory (National Relay Protection & Automation Equipment Quality Inspection and Testing Center); tested to IEC-TC95 international standard |
|
Warranty |
2 years from the date of arrival |
Applications

-
110kV substation main transformers - HV-side backup protection for main transformers in substation relay protection systems of 110kV and below. It works together with the differential protection (NR-500TD) in a complete main and backup scheme.

-
Industrial & mining step-down substations - backup protection for the main transformers in the main step-down stations of steel, chemical, cement, coking and mining plants. NAHO has supplied protection systems for projects of this type at 110kV, 66kV and 35kV.

-
Utility and municipal distribution projects - transformer backup protection in capacity-expansion works, heating plants, pumping stations and similar distribution projects.
Not intended for: generator protection, large PV inverter stations or traction power supply. Please contact us for those applications, as other NAHO models fit them better.
How It Works
Signal Acquisition
The relay samples the transformer HV-side three-phase current, zero-sequence current (I0), gap zero-sequence current (Ij0), three-phase voltage and zero-sequence voltage (U0) through its CT and PT inputs.
Protection Logic
The signals are compared in real time against the set values of each protection stage: time-limit overcurrent, directional overcurrent with voltage blocking, zero-sequence overcurrent, gap overcurrent, zero-sequence overvoltage and overload.
Fault Judgement
The relay confirms the fault condition after the set time delay. The voltage and direction criteria and the self-check of the PT, CT and operation circuit help prevent false operation when a measuring circuit is abnormal.
Trip Command And Recording
A trip command is issued through the digital outputs to isolate the fault, and the event is stored as a fault record. The data can be read out through the communication ports.
Suggested graphic: a simplified single-line diagram of a main transformer with HV-side CT/PT, the NR-500TB1 and its trip outputs.
Why Choose NAHO - Custom Engineering Capability
Built Around Your Project, Not Our Catalog

We are the factory behind the product. That means customization is decided in our own engineering room, not relayed through a trading chain.
-
Backed by decades of experience. NAHO traces its roots to 1992 (originally Dachang Electric in Yueqing, Liushi), and has focused on power automation and protection for 30+ years.
-
Customization you can specify. For the NR-500TB1 you can choose a rated current of 5A or 1A, a rated voltage of 100V or 400V, an auxiliary supply of AC/DC 110V, AC/DC 220V or DC 48V, and an optional communication configuration of 2 RS-485 and 2 Ethernet ports.
-
Custom enclosure and panel design for volume orders. Tooling for a custom enclosure is a real development cost, so we accept it once your order volume supports the investment.
-
OEM/ODM, project integration, technical support and after-sales service. One supplier covers the whole chain from selection to commissioning support.
-
Proven range of non-standard projects. We have delivered solutions for 144+ projects across 110kV, 66kV, 35kV and 10kV levels, in 11+ provinces and in sectors from substations and mines to rail projects. Our PV projects reach up to 10.96606 MW per project.
-
In-house production control. Each unit goes through SMT with AOI inspection, wave soldering, program burning, a 72-hour aging test, withstand-voltage and short-circuit checks, and a final factory inspection before shipment.
Certifications & Standards




- Type testing: all NAHO products are type-tested at the KETOP Laboratory (National Relay Protection & Automation Equipment Quality Inspection and Testing Center).
- International standard: tested to IEC-TC95.
- Standard drafting: NAHO took part in drafting the national standard for general technical requirements of standardized protection relays for 35kV and below (2019 and 2021). We also took part in drafting the energy industry standards NB/T 11054-2023, NB/T 11483-2024 and NB/T 11480-2024.
- State Grid: qualified supplier of State Grid since 2018.
- Enterprise recognition: National High-tech Enterprise and National-level "Specialized, Refined, Distinctive and Innovative" (Zhuanjingtexin) enterprise (2023).
-
Intellectual property: 70+ patents and software copyrights.
Case Studies / Project References
Project names are anonymized. They show our voltage range and industry coverage.
|
Project |
Voltage |
Industry |
|
Cement plant substation, Zhangye, Gansu |
110kV |
Building materials |
|
Construction-power substation, Xinjiang |
110kV |
Infrastructure |
|
Capacity-expansion power project, Chongqing |
110kV |
Municipal / utility |
|
Coking plant waste-heat power project, Shanxi |
66kV |
Metallurgy / coking |
|
Gold mine distribution room retrofit, Jilin |
66kV |
Mining |
|
District heating plant main step-down, Yanji, Jilin |
66kV–6kV |
Municipal heating |
|
Industrial zone substation retrofit, Anshan, Liaoning |
66kV |
Industrial |
|
Transition substation, Inner Mongolia |
66kV/10kV |
Utility |
|
Pumping station user substation, Jinan, Shandong |
36kV / 35kV |
Water supply |
|
Data center substation, Baotou, Inner Mongolia |
35kV |
Data center |
|
Distributed PV project, Ningbo, Zhejiang |
35kV |
Photovoltaic |
Featured projects:
-
Power distribution protection for an opening-ceremony venue at the 16th Asian Games (2010).
-
Three Gorges Yunyang reservoir area project.
FAQ
Q1: What is a transformer backup protection relay?
It is a microprocessor-based relay that protects a power transformer behind the main protection. If a fault is not cleared by the main protection, the backup relay detects it and trips the circuit breaker after a set delay.
Q2: Where is the NR-500TB1 used?
It is used on the HV side of main transformers in substations of 110kV and below, and in step-down stations of industrial and mining plants.
Q3: Can the NR-500TB1 be used on the 35kV or low-voltage side of a transformer?
The NR-500TB1 is designed for the 110kV side. For the 35kV side we offer the NR-500TB2, and for the medium and low-voltage sides we offer the NR-500TB3.
Q4: What protection functions does the NR-500TB1 provide?
It provides time-limit instantaneous overcurrent, complex-voltage-blocked directional overcurrent (2 time limits), zero-sequence-voltage-blocked directional zero-sequence overcurrent (2 time limits), gap overcurrent, zero-sequence overvoltage and overload protection. It also offers PT disconnection, PT voltage-loss, CT disconnection and operation circuit self-checks, plus fault recording.
Q5: Can the rated current or voltage be customized?
Yes. The rated current can be 5A or 1A depending on your CT, and the rated voltage can be 100V or 400V on request. The auxiliary supply is available as AC/DC 110V, AC/DC 220V or DC 48V.
Q6: What communication ports does it have?
One RS-485 port is standard. As an option you can order 2 RS-485 ports and 2 Ethernet ports.
Q7: What information do you need for a quote or selection?
Please send the project name and location, system voltage, application type, required protection functions, communication port needs, quantity and any customization requirements.
Q8: Do you provide OEM/ODM customization?
Yes. As the manufacturer, we provide OEM/ODM, custom enclosure and panel design for volume orders, project integration, technical support and after-sales service.
Q9: What is the minimum order quantity and warranty?
The MOQ is 10 units. The warranty is 2 years from the date of arrival.
Q10: Can you provide technical drawings, wiring diagrams and testing support?
Yes. Our engineers can supply technical drawings and wiring diagrams, and support you through selection and commissioning.
Get a Quote
Request a quote for the NR-500TB1. We reply within 24 hours.

Please include:
- Project name & location
- System voltage & frequency
- Application type (substation / industrial / mining / other)
- Required protection functions
- Communication port needs (RS-485 / Ethernet)
- Quantity (MOQ 10 units)
- Customization requirements (rated current, rated voltage, auxiliary supply, enclosure)