NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of transformer non-electrical protection relay nr-500tn in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.
Overview

NAHO is a manufacturer of power automation and microcomputer protection devices, with 30+ years of experience. We design and build the NR-500TN Transformer Non-Electrical Protection Relay in our own factory in Yueqing, Zhejiang, China, and every unit goes through in-house SMT assembly, 72-hour aging and full factory inspection.
The NR-500TN is a digital non-electrical protection and measurement device for transformers in substation relay protection systems rated up to 110kV. It takes the non-electrical signals from the transformer body, protects the transformer against faults that current and voltage relays cannot see, and measures oil temperature through 4–20mA analog inputs. A fault recording function documents each event for later analysis.
The NR-500TN is part of the NR-500T transformer protection series. The NR-500TD models act as main (differential) protection, and the NR-500TB models act as backup protection with measurement and control. The NR-500TN completes this set by handling the non-electrical side. A reasonably configured NR-500T line-up covers the main protection, backup protection, measurement, control and remote communication needs of a power transformer.
We supply the NR-500TN in standard form and, for project needs, in customized configurations, with OEM/ODM, project integration and technical support from the same factory.

Key Features & Protection Functions
-

Protection Functions
-
Non-electrical protection with 16 independent channels
-
-

Measurement Functions
- 2 channels of 4–20mA DC analog input for transformer oil temperature measurement and other DC transmitter signals
-
No voltage or current measurement channel, so it works alongside the NR-500TD and NR-500TB devices that cover the electrical quantities
Communication Functions
- 16-way digital input
-
10-way digital output
-
Fault recording
-

Communication Functions
-
1 RS-485 port as standard
-
Optional configuration: 2 RS-485 ports and 2 Ethernet ports
-
Where it sits in the NR-500T series
|
Model |
Role |
|
NR-500TD3 |
Main protection for three-winding transformers |
|
NR-500TD2 |
Main protection for two-winding transformers |
|
NR-500TB1 |
HV-side (110kV) backup protection |
|
NR-500TB2 |
35kV-side backup protection and measurement |
|
NR-500TB3 |
Medium/low-voltage side backup protection and measurement |
|
NR-500TN |
Non-electrical protection and oil temperature measurement |
Technical Specifications
|
Parameter |
Specification |
|
Applicable Scope |
Transformer non-electrical protection and measurement in substations up to 110kV |
|
Auxiliary Power Supply |
AC/DC 110V or AC/DC 220V; DC 48V |
|
Rated Frequency |
50Hz |
|
DC Analog Input |
2 channels, 4–20mA |
|
Non-Electrical Protection |
16 channels |
|
Digital Input |
16-way |
|
Digital Output |
10-way |
|
Communication Port |
1 RS-485 as standard; optional 2 RS-485 + 2 Ethernet |
|
Fault Recording |
Yes |
|
Operating Temperature |
-30℃ ~ +55℃ |
|
Relative Humidity |
≤95%, non-condensing |
|
Atmospheric Pressure |
80–110kPa |
|
Test Standard Atmospheric Condition |
+15℃ ~ +35℃, 45%–75% RH, 86–106kPa |
|
Front Panel Dimensions |
156mm (W) × 232mm (H) |
|
Body Depth |
171mm (198mm including terminals) |
|
Rear View Dimensions |
136mm (W) × 210mm (H) |
|
Panel Cutout |
approx. 137mm (W) × 211mm (H) |
|
Compliance |
Type-tested at KETOP Laboratory (National Relay Protection and Automation Equipment Quality Inspection and Testing Center); IEC-TC95 international standard testing |
The ambient air should be free of conductive dust, corrosive or explosive substances, and the installation site should have lightning, rain and snow protection.
Applications
The NR-500TN fits where a transformer already carries non-electrical signals that must be protected and recorded:

-
Substation transformer bays: non-electrical protection for main transformers in substations up to 110kV, paired with NR-500TD main protection and NR-500TB backup protection

-
Industrial and mining substations: transformer protection in plant distribution systems for metallurgy, mining, chemical and similar industries

-
Customer-owned substations: protection for transformers at EPC and contractor projects where main and backup protection are supplied together with this device
How It Works
Signal Acquisition
The NR-500TN receives the transformer's non-electrical contact signals through its digital inputs and oil temperature through the 4–20mA inputs.
Protection Logic
Each of the 16 non-electrical channels is evaluated by the device's protection logic.
Fault Judgement
The device determines whether a signal indicates an abnormal condition that needs action.
Output And Recording
The device issues its output through the 10 digital outputs, records the fault, and reports to the station through its communication port.
Suggested graphic: a simplified schematic from a desensitized project drawing.
Why Choose NAHO: Built Around Your Project, Not Our Catalog

We are the factory, so non-standard requests are handled by our own engineers and production line rather than passed on to a third party.
-
30+ years of manufacturing experience: NAHO traces back to 1992, and we have focused on power automation for decades.
-
Proven range: We have delivered 144+ projects across 110kV, 66kV, 35kV and 10kV, in 11+ provinces and industries from power and mining to steel, chemicals and transportation. We have also delivered distributed PV projects up to 10.96606MW.
-
Custom enclosure and panel design: Large-volume orders can have a custom enclosure. We invest in tooling once your order volume supports it.
-
Configuration options on this model: Communication can be specified as 1 RS-485 as standard or 2 RS-485 + 2 Ethernet; auxiliary supply can be chosen from AC/DC 110V, AC/DC 220V or DC 48V.
-
Full-process service: OEM/ODM customization, project integration, technical support and after-sales service. Our warranty is two years from delivery.
-
Controlled production: SMT with AOI inspection, wave soldering, 72-hour power aging at 24V/48V/220V, withstand-voltage and short-circuit testing, then final inspection including time synchronization within 2 seconds.
Certifications & Standards




- Type tests at the KETOP Laboratory (National Relay Protection and Automation Equipment Quality Inspection and Testing Center)
- IEC-TC95 international standard testing
- Co-drafter of national and industry standards: 35kV-and-below standardized protection relay requirements (2019 and 2021), NB/T 11054-2023 Anti-islanding Protection Device, NB/T 11483-2024 Urban Rail Transit AC Power Supply Relay Protection, and NB/T 11480-2024 Outdoor Control Cabinet Environmental Control Systems for Smart Substations
- State Grid qualified supplier (since 2018)
- National high-tech enterprise; National specialized and innovative "Little Giant" enterprise (2023)
- 70+ patents and software copyrights
Project References
|
Project |
Voltage Level |
Industry |
|
110kV substation, Gansu |
110kV |
Cement |
|
110kV construction substation, Xinjiang |
110kV |
Infrastructure |
|
66kV power distribution room renovation, Jilin |
66kV |
Mining |
|
66kV substation renovation, Anshan, Liaoning |
66kV |
Industrial |
|
35kV substation, Inner Mongolia |
35kV |
Rubber/Materials |
|
35kV substation, Shanxi |
35kV |
Coal mining |
|
35kV distribution project, Anhui |
35kV |
Aluminum |
|
35kV substation, Shandong |
35kV |
Chemicals |
|
35kV substation, Qinghai |
35kV |
Salt lake/Mining |
|
10kV distribution project, Qinghai |
10kV |
Coal mining |
Landmark projects:
- protection and distribution for the 2010 Asian Games opening ceremony power supply system; the Three Gorges Yunyang reservoir project.
- Project names above are desensitized to region and industry.
FAQ
Q1: What is a transformer non-electrical protection relay?
It is a protection device that monitors the signals of the transformer body, rather than current and voltage, and acts on them. The NR-500TN provides 16 non-electrical protection channels and measures oil temperature through 4–20mA inputs.
Q2: Where is the NR-500TN used?
In substation relay protection systems up to 110kV, as the non-electrical protection of a power transformer.
Q3: Does the NR-500TN replace the transformer's differential or backup protection?
No. The NR-500TN covers the non-electrical side only. Main protection is handled by the NR-500TD series and backup protection by the NR-500TB series; together they cover a transformer's protection, measurement, control and remote communication needs.
Q4: What does the NR-500TN provide?
16 non-electrical protection channels, 2 channels of 4–20mA input, 16-way digital input, 10-way digital output and fault recording.
Q5: What communication does it support?
It has 1 RS-485 port as standard. An optional configuration adds 2 RS-485 ports and 2 Ethernet ports.
Q6: What power supply does it need?
AC/DC 110V, AC/DC 220V or DC 48V.
Q7: What information do you need for a quote?
Project name and location, system voltage, the transformer and its non-electrical signals, communication needs, quantity and any custom requirements.
Q8: What is your MOQ?
10 units for the NR-500TN.
Q9: Do you provide OEM/ODM customization?
Yes. We are the manufacturer and offer OEM/ODM, project integration, technical support and after-sales service. Custom enclosures are available for large-volume orders.
Q10: Can you provide technical drawings, wiring diagrams and testing support?
Yes. Our technical team provides these, together with after-sales service, and we carry a two-year warranty counted from delivery.
Get a Quote

Tell us about your project and receive a quote within 24 hours.
- Project name & location
- System voltage & frequency
- Application type (substation / industrial / mining / other)
- Transformer and non-electrical signals to be connected
- Communication needs (1 RS-485 / 2 RS-485 + 2 Ethernet)
- Auxiliary supply (AC/DC 110V / AC/DC 220V / DC 48V)
- Quantity (MOQ 10 units)
- Customization requirements
Hot Tags: transformer non-electrical protection relay nr-500tn, China transformer non-electrical protection relay nr-500tn manufacturers, suppliers, factory