NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of transformer low voltage backup protection relay nr-500tb3 in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.
Overview

NAHO (NRUICN) designs, manufactures and tests the NR-500TB3 transformer low voltage backup protection relay in our own factory in Yueqing, Zhejiang, where we have built power automation equipment since 1992. The NR-500TB3 is a microcomputer-based backup protection and measurement-control device for the medium- and low-voltage sides of main transformers in substations rated 110kV and below.
Its job is to back up the main protection. When a fault on the transformer's medium- or low-voltage side is not cleared in time, the NR-500TB3 detects it and trips, so the fault does not spread to the rest of the system. It combines time-limited instantaneous overcurrent, complex-voltage-blocked directional overcurrent, overload protection and busbar earth-fault alarm with PT/CT self-supervision, an integrated operation box and fault recording.
The NR-500TB3 belongs to the NR-500T transformer protection family. The NR-500TD3 and NR-500TD2 provide main protection for three-winding and two-winding transformers. The NR-500TB1 covers the 110kV-side backup, the NR-500TB2 covers the 35kV-side backup and measurement-control, and the NR-500TN covers non-electrical quantity protection. Because we manufacture the whole family ourselves, the NR-500TB3 is available in standard and customized configurations, including rated current, rated voltage and auxiliary power supply.

Key Features & Protection Functions
-

Protection Functions
-
Time-limited instantaneous overcurrent protection (ANSI 50/51)
-
Complex-voltage-blocked directional overcurrent protection, 2 time stages (ANSI 51V/67)
-
Complex-voltage start for HV-side overcurrent (ANSI 51V)
-
Overload protection (ANSI 51)
-
Busbar earth-fault alarm (ANSI 64)
-
-

Measurement Functions
- 6-phase + I0 current protection/measurement channel
-
3-phase + U0 voltage measurement channel
-
4–20mA DC analog signal acquisition
Communication Functions
- 1 × RS-485 port as standard
-
Optional configuration: 2 × RS-485 + 2 × Ethernet ports
-

Monitoring & Self-Supervision Functions
-
16-way digital input; 14-way digital output
-
PT failure self-check; PT disconnection self-check; CT disconnection self-check
-
Integrated operation box
-
Operation circuit self-check (ANSI 74)
-
Fault recording
-
How the NR-500TB3 differs from the other backup models
|
Model |
Typical position |
Distinguishing functions |
|
NR-500TB1 |
Main transformer 110kV-side backup |
Gap overcurrent, zero-sequence overvoltage, zero-sequence-voltage-blocked directional zero-sequence overcurrent |
|
NR-500TB2 |
Main transformer 35kV-side backup & measurement-control |
Busbar earth-fault alarm, operation box |
|
NR-500TB3 |
Main transformer medium- and low-voltage-side backup |
Complex-voltage start for HV-side overcurrent, busbar earth-fault alarm, operation box |
Technical Specifications
|
Parameter |
Specification |
|
Applicable Scope |
Backup protection for the medium- and low-voltage sides of main transformers in substations rated 110kV and below |
|
Current Protection/Measurement Channel |
6-phase + I0 |
|
Voltage Measurement Channel |
3-phase + U0 |
|
Digital Input |
16-way |
|
Digital Output |
14-way |
|
Communication Port |
1 × RS-485 as standard; optional 2 × RS-485 + 2 × Ethernet |
|
Protection Functions |
Time-limited instantaneous overcurrent; complex-voltage-blocked directional overcurrent (2 time stages); complex-voltage start for HV-side overcurrent; overload; busbar earth-fault alarm |
|
Self-Supervision |
PT failure, PT disconnection, CT disconnection, operation circuit self-check |
|
Other Functions |
Operation box; fault recording |
|
Auxiliary Power Supply |
AC/DC 110V or AC/DC 220V; DC 48V |
|
Rated Voltage |
100V (400V customized) |
|
Rated Frequency |
50Hz |
|
Rated Current |
5A (1A customized) |
|
DC Analog Signal Acquisition |
4–20mA |
|
Operating Temperature |
-30℃ ~ +55℃ |
|
Relative Humidity |
≤95%, non-condensing |
|
Atmospheric Pressure |
80–110kPa |
|
Test Standard Atmospheric Condition |
15℃ ~ 35℃, 45% ~ 75% RH, 86 ~ 106kPa |
|
Installation Environment |
The surrounding air must be free of conductive dust, corrosive gas and explosive substances, and the site must be protected from rain, snow and similar weather |
|
Front Panel Dimensions |
156mm (W) × 232mm (H) |
|
Depth |
171mm (body); 198mm including terminals |
|
Rear View Dimensions |
136mm (W) × 210mm (H) |
|
Panel Cutout |
approx. 137mm (W) × 211mm (H) |
|
Type Testing |
KETOP Laboratory type test; IEC-TC95 international standard testing |
Applications

-
Substation main transformer backup (110kV and below): backup protection on the medium- and low-voltage sides of main transformers, working with the NR-500TD main protection relays.

-
Industrial user substations: main-transformer backup in the substations of metallurgy, mining, chemical and cement plants, where a transformer fault must not stall production.

-
Substation upgrades and expansions: replacing or adding backup protection on existing main transformers, with the rated current, rated voltage and communication ports configured to match the project.
How It Works
Signal Acquisition
The relay samples the medium- and low-voltage-side currents (6-phase + I0) and voltages (3-phase + U0) from the CTs and PTs.
Protection Logic
It compares the sampled values against the set thresholds. Complex-voltage and directional elements decide whether an overcurrent is a real fault.
Fault Judgement
PT and CT self-checks confirm that the measurements are valid, so a broken CT or PT circuit does not cause a false operation.
Trip Command
If the fault persists beyond the set time stage, the relay trips the breaker through its operation box and records the event with fault recording.
Why Choose NAHO: Built Around Your Project, Not Our Catalog

We are the manufacturer, not a reseller. The NR-500TB3 is designed, assembled, aged and tested in our own factory, so the people who build it can adjust it for your project.
-
Customizable ratings you can verify on the datasheet. Rated current is 5A as standard and 1A on request. Rated voltage is 100V as standard and 400V on request. Auxiliary power can be AC/DC 110V, AC/DC 220V or DC 48V. Communication can be 1 × RS-485 or 2 × RS-485 + 2 × Ethernet.
-
30+ years of power automation manufacturing. Our predecessor company was founded in 1992 in Yueqing Liushi.
-
Customization proven across 144+ projects. Our project record covers 110kV, 66kV, 35kV and 10kV voltage levels in substations, mines, steel, chemical, transport and distributed PV, across many provinces. Distributed PV projects reach up to 10.96606 MW.
-
OEM/ODM, project integration, technical support and after-sales service. Custom enclosure appearance is available for large-volume orders, because the tooling investment is justified once order volume supports it.
-
Every unit is tested before shipment. Production includes SMT with AOI inspection, a 72-hour aging test, withstand-voltage and short-circuit checks, and a final factory inspection.
Certifications & Standards




- Type-tested at the KETOP Laboratory (National Relay Protection and Automation Equipment Quality Inspection and Testing Center)
- Passed IEC-TC95 international standard testing
- Drafting participant of the national standard for 35kV and below standardized relay protection devices (2019 and 2021)
- Drafting participant of energy industry standards NB/T 11054-2023 (Technical Specification for Anti-islanding Protection Devices), NB/T 11483-2024 (Technical Specification for Relay Protection of AC Power Supply Systems for Urban Rail Transit) and NB/T 11480-2024 (Technical Specification for Environment Control Systems of Outdoor Control Cabinets in Smart Substations)
- State Grid qualified supplier (since 2018)
- National High-tech Enterprise; National "Specialized, Refined, Distinctive and Innovative" Enterprise (2023)
- 70+ patents and software copyrights
- Member and executive-council member unit of the Relay Protection and Automation Equipment Branch of the China Electrical Equipment Industry Association
Case Studies / Project References
NAHO has delivered 144+ power projects. A selection is shown below. These are company project references, not a list of NR-500TB3 installations.
|
Project |
Voltage Level |
Industry |
|
Shandan Tieqi Cement 110kV Substation, Zhangye, Gansu |
110kV |
Cement |
|
Chunlong 110kV Substation, Jinta County, Jiuquan, Gansu |
110kV |
Industrial |
|
Hash Tarilega 110kV Construction Substation, Xinjiang |
110kV |
Construction power |
|
Haigou Gold Mine 66kV Distribution Room Renovation, Jilin |
66kV |
Mining |
|
Yanji Central Heating Plant 66kV–6kV Distribution, Jilin |
66kV–6kV |
Heating |
|
Anshan Datongwan Industrial Zone 66kV Substation Renovation, Liaoning |
66kV |
Industrial |
|
Baotou Furong 35kV Substation Expansion, Inner Mongolia |
35kV |
Industrial |
|
Jinan Longshan Relay Pump Station 35kV Substation, Shandong |
35kV |
Water supply |
|
Shanxi Datong Xing'ergou Coal Mine 35kV/6kV Substation |
35kV/6kV |
Mining |
|
Tibet Dangdui 35kV Substation |
35kV |
Utility |
|
Anhui Shengxin Aluminum 35kV Distribution Project |
35kV |
Metallurgy |
|
Shanghai Hudong Heavy Machinery Donggou Plant 35kV–6.3kV Distribution |
35kV–6.3kV |
Machinery |
Landmark projects
-
Power supply protection and distribution for the Haixinsha Square opening ceremony, 16th Asian Games (2010)
-
Three Gorges Yunyang Reservoir area project
FAQ
Q1: What is a transformer low voltage backup protection relay?
It is a protection device installed on a main transformer's low-voltage side, and on the medium-voltage side for three-winding transformers. It backs up the main protection and trips the breaker if a fault is not cleared in time.
Q2: Where is the NR-500TB3 used?
It is used in substations rated 110kV and below, on the medium- and low-voltage sides of main transformers. It is also used in industrial user substations such as mining, metallurgy and chemical plants.
Q3: Can the NR-500TB3 be used as the main protection of a transformer?
No. The NR-500TB3 is a backup protection device. For main protection, use the NR-500TD3 (three-winding) or NR-500TD2 (two-winding) in the same family.
Q4: What protection functions does the NR-500TB3 provide?
It provides time-limited instantaneous overcurrent, complex-voltage-blocked directional overcurrent with 2 time stages, complex-voltage start for HV-side overcurrent, overload protection and busbar earth-fault alarm. It also provides PT/CT self-checks, an operation box, operation circuit self-check and fault recording.
Q5: What is the difference between the NR-500TB1, NR-500TB2 and NR-500TB3?
The NR-500TB1 backs up the 110kV side and adds gap overcurrent and zero-sequence overvoltage. The NR-500TB2 backs up the 35kV side with measurement-control. The NR-500TB3 backs up the medium- and low-voltage sides and adds complex-voltage start for HV-side overcurrent.
Q6: Can the rated current, rated voltage or power supply be customized?
Yes. Rated current is 5A as standard and 1A on request. Rated voltage is 100V as standard and 400V on request. Auxiliary power is available as AC/DC 110V, AC/DC 220V or DC 48V.
Q7: What communication ports are available?
One RS-485 port comes as standard. You can also order 2 × RS-485 + 2 × Ethernet ports.
Q8: Do you provide OEM/ODM customization?
Yes. We are the manufacturer and offer OEM/ODM, project integration, technical support and after-sales service. Custom enclosure appearance is available for large-volume orders.
Q9: What is the minimum order quantity and warranty?
The MOQ is 10 units. The warranty is 2 years from the date of arrival.
Q10: What information do you need to quote?
See the list in the Get a Quote section below.
Get a Quote

Send us the following and we will reply within 24 hours:
- Project name & location
- System voltage & frequency
- Transformer winding type (two-winding / three-winding) and the side to be protected
- Application type (substation / industrial / mining / other)
- Required protection functions
- Rated current (5A / 1A) and rated voltage (100V / 400V)
- Auxiliary power supply (AC/DC 110V / AC/DC 220V / DC 48V)
- Communication port requirements
- Quantity
- Customization requirements
Hot Tags: transformer low voltage backup protection relay nr-500tb3, China transformer low voltage backup protection relay nr-500tb3 manufacturers, suppliers, factory