NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of transformer relay nr-610 in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.
Overview

The NR-610 is a microcomputer-based transformer relay for small-current grounding systems rated 10kV and below. It protects distribution transformers and plant auxiliary transformers against overcurrent, earth faults, overload and abnormal voltage, and it trips the transformer bay when those conditions go beyond set limits.
The relay is built on a general-purpose platform. One hardware base carries the full protection set, so the same unit can sit on the incoming side or the outgoing side of a transformer and be configured for each. Non-electrical quantity inputs let it act on signals from the transformer itself, such as those from temperature and gas devices. These signals can also trigger a trip or an alarm. Note that NR-610 provides backup and feeder-level protection. It is not a differential relay and is not intended as a transformer's main differential protection.
The NR-610 is available in standard form and in customized configurations. Digital inputs can be user-defined, and rated current can be specified as 5A or 1A to match your CT.

Model Description
|
Model |
Application |
|
NR-610 |
Incoming and feeder cabinet protection, including transformer bays |
|
NR-611 |
Two-way incoming protection and automatic transfer |
|
NR-612 |
Sectional switch protection and automatic transfer |
|
NR-613 |
PT cabinet, monitoring of two PTs and paralleling |
|
NR-613A |
PT cabinet, monitoring and protection of one PT |
|
NR-614 |
Motor cabinet protection |
Key Features & Protection Functions
-

Protection Functions
- Three-section overcurrent protection with direction and complex-voltage lockout
-
Inverse time-limit overcurrent protection
-
High-current blocking trip
-
Negative-sequence overcurrent protection
-
Overload protection (alarm or trip)
-
Three-section zero-sequence overcurrent protection
-
Inverse time-limit zero-sequence overcurrent protection
-
Post-acceleration protection
-
Reclosing
-
Non-electric quantity protection
-
Overvoltage, undervoltage and zero-sequence overvoltage protection (each set for alarm or trip)
-

Measurement Functions
- 3-phase + I0 current protection/measurement channel
-
3-phase + U0 voltage measurement channel
Communication Functions
- RS-485 port
-
Modbus / IEC 60870-5-101 / IEC 60870-5-103 protocols
-

Monitoring & Self-Diagnostic Functions
-
10-way digital input (customizable)
-
5-way dry-contact digital output
-
Busbar insulation monitoring
-
PT and CT circuit-break self-check
-
Operating circuit self-check
-
Fault recording
-
How the Relay Protects a Transformer
Signal Acquisition
The relay measures 3-phase current, zero-sequence current, 3-phase voltage and zero-sequence voltage from the transformer bay.
Protection Logic
The microprocessor compares the measured values with the set thresholds for overcurrent, earth fault, overload and abnormal voltage.
Fault Judgment
The relay decides between alarm and trip according to the setting and the severity. Self-checks on the CT, PT and operating circuit run in the background, so a measurement problem is reported rather than ignored.
Trip Command And Record
The output contact trips the breaker, and the event is stored as a fault record for later analysis.
Technical Specifications
|
Parameter |
Specification |
|
Applicable Scope |
Small-current grounding systems, 10kV and below; transformer bay, incoming and feeder protection |
|
Rated Voltage |
100V |
|
Rated Frequency |
50Hz |
|
Rated Current |
5A, 1A (customized) |
|
Auxiliary Power Supply |
AC/DC 85V–265V; DC 48V; DC 24V |
|
Current Protection/Measurement Channel |
3-phase + I0 |
|
Voltage Measurement Channel |
3-phase + U0 |
|
Digital Input |
10-way (customizable) |
|
Digital Output |
5-way dry contacts |
|
Communication Port |
RS-485 |
|
Communication Protocol |
Modbus / 101 / 103 |
|
Installation |
Flush-mounted (panel mounting) |
|
Operating Temperature |
-30℃ ~ +55℃ |
|
Relative Humidity |
≤95%, non-condensing |
|
Atmospheric Pressure |
80–110kPa |
|
Test Standard Atmospheric Condition |
15℃~35℃, 45%~75% RH, 86~106kPa |
|
Dimensions |
128mm (W) × 188mm (H) × 108mm (D); body depth 90mm |
|
Panel Cutout |
123mm (W) × 143mm (H), ±0.5mm |
|
Compliance |
IEC-TC95 international standard tested; KETOP laboratory type tested |
Applications

-
Distribution transformer incoming bays
Protects the feeder bay that supplies a 10kV and below distribution transformer, covering overcurrent, earth fault and overload. -
Auxiliary and station transformers
Fits plant and station service transformers where overcurrent, overload and non-electrical signals must be handled in one relay. It can be installed on the high-voltage side or the low-voltage side of the transformer.

-
Industrial plant transformer feeders
Suits transformer feeders in mining, steel, chemical and other industrial distribution systems.

-
Incoming and outgoing cabinetsWhere a transformer bay sits alongside other feeders, the same relay platform serves the rest of the switchgear lineup.
Why Choose NAHO - Custom Engineering Capability

Built Around Your Transformer Project, Not Our Catalog
- Customizable I/O: The 10-way digital input can be user-defined, so the relay maps to your transformer's trip, alarm and status signals rather than a fixed layout.
-
Rated current to your CT: 5A or 1A, specified at order.
-
A relay for each bay: The NR-61x series covers feeder, dual-incoming, sectional switch, PT cabinet and motor applications on the same platform, so a whole switchgear lineup can share one family of devices.
-
OEM/ODM, project integration, technical support and after-sales service.
-
Enclosure customization on volume orders: Custom appearance requires new tooling. We accept it when your order volume supports that investment.
-
Experience behind it: Founded in 1992, over 30 years in power automation, with project references across 110kV, 66kV, 35kV and 10kV levels and more than 11 provinces.
-
Warranty: 2 years, counted from arrival of goods.
Certifications & Standards




- Type tests by the National Relay Protection and Automation Equipment Quality Inspection Center (KETOP Laboratory)
- IEC-TC95 international standard tested
- ISO 9001, CCC, CE; IEC 60255 / IEC 61850 related type test reports
- State Grid qualified supplier (since 2018)
- Drafting participant in national and industry standards: the national standard for general technical requirements of relay protection devices at 35kV and below (2019 and 2021), NB/T 11054-2023 anti-islanding protection, NB/T 11483-2024 urban rail transit AC power supply relay protection, and NB/T 11480-2024 smart substation outdoor control cabinet environment control
- 70+ patents and software copyrights
Case Studies / Project References

NAHO's project record spans 144+ projects across voltage levels from 110kV to 10kV.
Featured projects
- Power supply system protection and distribution works for the Haixinsha Square opening ceremony, 16th Asian Games (2010)
- Sanxia Yunyang reservoir area project
Reference table (selection from NAHO's project library)
|
Project |
Voltage |
Industry |
|
Zhengzhou Dali Food 10kV expansion |
110kV |
Food manufacturing |
|
Yanji central heating plant main step-down 66kV switchgear |
66kV |
Heating / energy |
|
Liaoning Yingkou Deyuan carbon plant |
66kV |
Industrial |
|
Shandong Jinan Longshan relay pump station 35kV user substation |
35kV |
Water supply |
|
Ningbo 35kV PV project |
35kV |
Photovoltaic |
|
Inner Mongolia Baotou Furong 35kV substation expansion |
35kV |
Utilities |
|
Shanxi Changzhi Xinyuan farm substation |
10kV |
Agriculture |
|
Qinghai Menyuan Guala No.1 coal mine distribution room |
10kV |
Mining |
FAQ
Q1: What is a transformer relay?
A transformer relay is a protection device that monitors the current and voltage on a transformer bay and trips the breaker when it detects overcurrent, earth fault, overload or abnormal voltage. The NR-610 does this for transformers in 10kV and below systems.
Q2: Where is the NR-610 used?
It is used in 10kV and below small-current grounding systems, mainly in transformer incoming bays, auxiliary and station transformer feeders, and industrial plant distribution.
Q3: Can the NR-610 be used for both the high-voltage and low-voltage side of a transformer?
Yes. It can be applied on either side of the transformer, as long as the system is within its 10kV and below rating.
Q4: Is the NR-610 a transformer differential relay?
No. NR-610 provides overcurrent, earth-fault, overload, voltage and non-electric quantity protection. It is not a differential relay. If you need differential protection as the main protection, tell us your requirements and we will advise.
Q5: What protection functions does the NR-610 provide?
Three-section overcurrent with direction and complex-voltage lockout, inverse time-limit overcurrent, negative-sequence overcurrent, overload (alarm or trip), three-section zero-sequence overcurrent, post-acceleration, reclosing, over/undervoltage and zero-sequence overvoltage (alarm or trip), and non-electric quantity protection.
Q6: Can the digital I/O or rated current be customized?
Yes. The 10 digital inputs can be user-defined, and rated current can be 5A or 1A according to your CT configuration.
Q7: What communication protocols are supported?
Modbus, IEC 60870-5-101 and IEC 60870-5-103 over an RS-485 port.
Q8: Do you provide OEM/ODM customization?
Yes. We provide OEM/ODM, project integration, technical support and after-sales service. Custom enclosure design is accepted for volume orders because of tooling cost.
Q9: What is the minimum order quantity?
The MOQ for NR-610 is 20 units.
Q10: What information do you need for a quote?
See the list below.
Get a Quote

Send us the following and we will reply within 24 hours:
- Project name and location
- System voltage and frequency
- Transformer details and which side the relay protects (high or low voltage)
- Required protection functions
- Communication protocol needs
- Rated current (5A or 1A)
- Quantity
-
Customization requirements (I/O, enclosure, OEM)
Contact: Dr502963156@gmail.com · WhatsApp / Telegram: +86 138 6872 1792
Hot Tags: transformer relay nr-610, China transformer relay nr-610 manufacturers, suppliers, factory