NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of ref protection relay nr-660 in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.

 

Overview

 

 

NH10-2

 

The NR-660 is a microcomputer-based protection and control relay for medium-voltage systems rated 66kV and below. Buyers who search for a "REF protection relay" are usually looking for reliable earth-fault protection on feeders and auxiliary equipment. The NR-660 addresses this with three-stage zero-sequence overcurrent, inverse-time zero-sequence overcurrent, zero-sequence overvoltage, bus insulation monitoring, and PT/CT circuit self-supervision, all on a single platform. (Note: it does not include a restricted earth fault (ANSI 64REF) differential function. See the FAQ.)

Built on a universal design concept, the NR-660 serves as general protection for incoming feeders, outgoing feeders, auxiliary transformers, motors and capacitors. It is designed to be mounted directly on the switchgear panel. A 5-inch color display, two-channel temperature and humidity monitoring, strong anti-interference performance and tolerance of harsh environments make it well suited to decentralized installation.

 

The series is available in four variants, and all can be supplied in standard or customized configurations, including digital I/O, rated current and output contacts: NR-660, NR-661, NR-662 and NR-663.

product-5712-3213

 

 

Model Overview

 

 

Model

Application

NR-660

Incoming and outgoing feeder cabinet protection

NR-661

Protection and automatic switching for two-way incoming power supply

NR-662

Section switch protection and automatic switching

NR-663

PT cabinet: monitoring and paralleling of two PT groups

 

 

Key Features & Protection Functions

 

  • product-1200-800

    Protection Functions (NR-660)

    • Three-stage overcurrent protection with directional element and complex-voltage lockout
    • Inverse-time overcurrent protection

    • Overload protection (alarm or trip)

    • Earth-fault protection: three-stage zero-sequence overcurrent, inverse-time zero-sequence overcurrent

    • Negative-sequence overcurrent protection

    • Post-acceleration protection

    • Auto-reclosing

    • Over-voltage and under-voltage protection (alarm or trip)

    • Zero-sequence overvoltage protection (alarm or trip)

    • Voltage reverse-phase-sequence protection

    • Excessive starting time and locked-rotor protection (for motor applications)

    • Non-electric quantity protection

  • product-5712-4284

    Measurement Functions

    • 3-phase + I0 current protection/measurement channels
    • 3-phase + U0 voltage measurement channels

     

    Communication Functions

    • RS-485 and Ethernet ports
    • Modbus, IEC 60870-5-101 and IEC 60870-5-103 protocols

  • product-1265-949

    Monitoring & Supervision Functions

    • Bus insulation monitoring

    • PT circuit and CT circuit self-supervision

    • Operation circuit self-supervision

    • Fault recording

    • Two-channel temperature and humidity monitoring

    • 5-inch color LCD display

    • Operation box (operating circuit) function

    • 12-way digital input (user-definable)

    • 6–13 dry-contact digital outputs (customizable)

     

    Functions by Variant (long-tail coverage)

    • NR-661: protection for two-way incoming power supply, with automatic backup power switching and recovery

    • NR-662: section switch protection with automatic switching

    • NR-663: PT cabinet monitoring, bus insulation monitoring, PT paralleling and PT circuit self-supervision

 

 

Technical Specifications

 

Parameter

Specification

Applicable Scope

66kV and below; general protection for incoming, outgoing, auxiliary transformer, motor and capacitor circuits

Rated Voltage

100V

Rated Frequency

50Hz

Rated Current

5A, 1A (customized)

Auxiliary Power Supply

AC/DC 85V–265V; DC 48V

Current Protection/Measurement Channel

3-phase + I0 (NR-660□)

Voltage Measurement Channel

3-phase + U0 (NR-660□)

Digital Input

12-way (user-definable)

Digital Output

6–13 dry contacts (customizable)

Communication Port

RS-485 / Ethernet

Communication Protocol

Modbus / IEC 60870-5-101 / IEC 60870-5-103

Display

5-inch color LCD

Operating Temperature

-30℃ ~ +55℃

Relative Humidity

≤95%, non-condensing

Atmospheric Pressure

80–110kPa

Test Standard Atmospheric Condition

15℃~35℃, 45%~75% RH, 86~106kPa

Dimensions

149mm(W) × 188mm(H) × 108mm(D)

Panel Cutout

139±0.5mm(W) × 159±0.5mm(H)

Environmental Requirement

No acid, alkali, corrosive or explosive substances in the surrounding air; lightning, rain and snow protection required

Type Testing

KETOP Laboratory type test; IEC-TC95 international standard testing

 

Applications

 

 

modular-1
  • Substation feeder bays: incoming and outgoing feeder protection

  • Auxiliary transformer circuits: general protection for station and distribution transformers

  • Motor circuits: with excessive-starting-time and locked-rotor protection

modular-2
  • Capacitor bank circuits: general protection

  • Two-way incoming and sectionalizing cabinets (NR-661 / NR-662): protection with automatic switching

modular-3
  • PT cabinets (NR-663): monitoring and paralleling of two PT groups

  • Industrial and mining distribution systems: metallurgy, chemical, coal, cement and similar plants (see case references below)

 

Detailed industry pages: Substations · Industrial & Mining

 

How It Works

 

Signal Acquisition

Three-phase current and I0, three-phase voltage and U0 are sampled from the CT and PT.

Protection Logic

The microprocessor runs the configured overcurrent, earth-fault, voltage and supervision logic continuously.

Fault Judgment

Pickup and time-delay settings decide between alarm and trip; the PT/CT self-supervision functions block false operation.

Trip And Record

A trip command goes to the breaker through the dry contacts, the fault record is saved, and events are sent over Modbus/101/103.

 

 

Why Choose NAHO - Built Around Your Project, Not Our Catalog

 

product-1267-1027

  • Customizable where it matters: digital inputs are user-definable, digital outputs can be configured between 6 and 13 dry contacts, and rated current can be specified as 5A or 1A to match your CT.
  • Four variants, one platform: feeder, dual-incoming, sectionalizing and PT cabinet needs are covered by the same hardware family, which simplifies spares and training.

  • Custom enclosure and panel design: available for large-volume orders, where tooling investment is justified.

  • Full service scope: OEM/ODM customization, project integration, technical support and after-sales service.

  • Proven in non-standard projects: more than 140 projects across 110kV to 10kV, in power, mining, steel, chemical, construction and transportation.

  • Thirty years of manufacturing experience since 1992, with a 2-year warranty from arrival.

  • Stable quality: every unit passes SMT with AOI inspection, 72-hour aging, voltage withstand and short-circuit tests, and factory inspection.

 

Certifications & Standards

 

product-1221-1628
product-1268-1711
product-1267-1710
product-1268-1711
  • Type-tested at the KETOP Laboratory (National Quality Supervision and Inspection Center for Protection Relays and Automation Equipment)
  • Passed IEC-TC95 international standard testing
  • Participant in drafting national and energy-industry standards
  • State Grid qualified supplier
  • More than 70 patents and software copyrights

 

Case Studies / Project References

 

 

NAHO has delivered protection and automation systems for projects including the venue power supply protection for the 2010 16th Asian Games opening ceremony at Haixinsha Square, the Three Gorges Yunyang reservoir project, and wind farm and high-speed railway projects.

 

Project

Voltage Level

Industry

Yingkou Deyuan Carbon Plant, Liaoning

66kV

Industrial

Lanxian Fengda Coking Waste-Heat Power Generation Project, Shanxi

66kV

Power / Coking

 

 

FAQ

 

Q1: What is the NR-660 protection relay?

It is a microcomputer protection and control relay for systems rated 66kV and below. It covers feeder, transformer, motor and capacitor protection with a 5-inch color display.

Q2: Where is it used?

It is used in incoming and outgoing feeder cabinets, auxiliary transformer circuits, motor and capacitor circuits, sectionalizing cabinets and PT cabinets, in substations and industrial distribution systems.

Q3: Does the NR-660 provide Restricted Earth Fault (REF, ANSI 64REF) protection?

No. The NR-660 provides three-stage zero-sequence overcurrent, inverse-time zero-sequence overcurrent, zero-sequence overvoltage, bus insulation monitoring, and PT/CT supervision for earth-fault detection. It does not include a REF differential function. If your project requires REF, send us your requirement and we will advise on a suitable solution.

Q4: What protection functions does it provide?

Three-stage directional overcurrent with complex-voltage lockout, inverse-time overcurrent, overload, three-stage zero-sequence overcurrent, negative-sequence overcurrent, post-acceleration, reclosing, over/under-voltage, zero-sequence overvoltage, reverse phase sequence, excessive starting time and locked-rotor protection.

Q5: Can the digital I/O or rated current be customized?

Yes. Digital inputs are user-definable, digital outputs can be set between 6 and 13 dry contacts, and rated current can be 5A or 1A according to your CT.

Q6: What communication protocols are supported?

Modbus, IEC 60870-5-101 and IEC 60870-5-103, over RS-485 or Ethernet.

Q7: What are the dimensions and panel cutout?

149 × 188 × 108mm (W×H×D) with a panel cutout of 139±0.5 × 159±0.5mm.

Q8: Which variant should I choose?

NR-660 for feeders, NR-661 for two-way incoming with automatic switching, NR-662 for section switches, NR-663 for PT cabinets.

Q9: Do you provide OEM/ODM customization?

Yes, including large-volume custom enclosure design, plus technical support and after-sales service.

Q10: Can you provide technical drawings, wiring diagrams and testing support?

Yes. Contact us with your project details.

Q11: What is the minimum order quantity?

Please contact our team for the MOQ of this series.

 

Get a Quote

 

product-1269-952

Please send:

  • Project name & location
  • System voltage & frequency
  • Application type (feeder / dual incoming / section switch / PT cabinet / transformer / motor)
  • Required protection functions
  • Communication protocol needs
  • Rated current (5A / 1A) and digital I/O requirements
  • Quantity
  • Customization requirements

 