NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of vt paralleling control device nr-623 in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.
Overview

The NR-623 is a microprocessor-based VT monitoring, protection and paralleling device. It belongs to the NR-620 series, which is designed for 10kV and below small-current grounding systems. It is built for the PT cabinet, the point where bus voltage is measured, and where two VT groups must be monitored and paralleled when the bus is split.
The NR-623 measures two independent VT groups, each with three phase voltages plus zero-sequence voltage (U0). On this input it provides over-voltage, under-voltage and zero-sequence over-voltage protection, bus insulation monitoring and PT wire-break self-check. It also performs PT paralleling and records faults. Over-voltage, under-voltage and zero-sequence over-voltage can each be set to alarm or trip.
It suits panel builders and EPC teams working on 10kV and below distribution. Wiring is straightforward: 12 digital inputs, 4 dry-contact outputs and standard SCADA protocols. If your project uses only a single VT group, the sister model NR-623A covers one-group monitoring and protection.
We design and manufacture the NR-623 ourselves in Yueqing, Zhejiang. Rated values and digital I/O can be fixed to your project drawings before production.

Key Features & Protection Functions
-

Voltage protection
-
Over-voltage protection: alarm or trip
-
Under-voltage protection: alarm or trip
-
Zero-sequence over-voltage protection: alarm or trip
-
-

Bus and VT supervision
- Bus insulation monitoring
-
PT wire-break self-check
-
PT paralleling for two VT groups
Recording and I/O
-
Fault recording for post-event analysis
-
12 digital inputs, with user-defined input functions
-
4 dry-contact outputs
-

Communication
- RS-485 or Ethernet (optional)
-
Modbus, IEC 60870-5-101 and 103 protocols
Hardware
-
Wide-range power supply: AC/DC 85–265V or DC48V
- Standard 149 × 188 mm front panel with a 139 × 159 mm cut-out
Technical Specifications
|
Category |
Parameter |
NR-623 |
|
Application |
Cabinet type |
PT cabinet with two VT groups (monitoring and paralleling) |
|
Application |
System |
10kV and below, small-current grounding, NR-620 series |
|
Measurement |
Voltage channels |
2 × (3-phase + U0) |
|
Measurement |
Rated voltage / frequency |
100V / 50Hz |
|
Measurement |
Rated current |
5A (1A on request) |
|
Functions |
Voltage protection |
Over-voltage, under-voltage, zero-sequence over-voltage; each set to alarm or trip |
|
Functions |
Supervision |
Bus insulation monitoring; PT wire-break self-check |
|
Functions |
Paralleling and recording |
PT paralleling; fault recording |
|
I/O |
Digital inputs |
12, functions defined by the user |
|
I/O |
Digital outputs |
4 dry contacts |
|
Communication |
Port |
RS-485 / Ethernet (optional) |
|
Communication |
Protocols |
Modbus, 101, 103 |
|
Power |
Auxiliary supply |
AC/DC 85–265V, or DC48V |
|
Environment |
Temperature / humidity / pressure |
−30 to +55 °C / ≤95% non-condensing / 80–110 kPa |
|
Mechanical |
Front panel |
149 × 188 mm |
|
Mechanical |
Depth / cut-out |
108 mm / 139 × 159 mm (±0.5) |
Air around the device must be free of acid, alkali or explosive substances.
Applications
The NR-623 is a PT-cabinet device, so it fits wherever a 10kV and below bus is supplied through two VT groups. NAHO supplies relays across five scenario groups.

-
Substations
Bus voltage monitoring in PT cabinets on 10kV and below distribution busbars. The device supervises both VT groups and parallels them when needed. -
Hydropower
Voltage monitoring and zero-sequence supervision in station auxiliary and generator-side medium-voltage cabinets.

-
Distributed PV
PT cabinets at the point where a PV plant connects to a 10kV and below system, where bus voltage supervision and insulation monitoring are needed. -
Industrial & Mining
PT cabinets in plant and mine distribution rooms, where insulation monitoring helps detect grounding faults in small-current grounding systems.

-
Rail & Transportation
PT cabinets in traction-related and station-level medium-voltage distribution.
How It Works
Signal Acquisition
Both VT groups feed three phase voltages and the zero-sequence voltage U0 to the device. The 12 digital inputs bring in breaker and bus-tie states, and their functions can be defined by the user.
Protection Logic
The processor evaluates the voltage signals against the over-voltage, under-voltage and zero-sequence over-voltage settings. It also runs bus insulation monitoring and the PT wire-break self-check.
Fault Judgment
When a setting is exceeded, the device decides whether to alarm or trip, according to how that function was configured. If a VT wire-break is detected, it flags the abnormal input.
Output And Record
The 4 dry-contact outputs send the alarm or trip command to your panel. The paralleling function acts on the two VT groups. Fault recording stores the event, and RS-485 or Ethernet (optional) reports it to the SCADA system over Modbus, 101 or 103.
Why Choose NAHO: Custom Engineering Capability

A PT cabinet with two VT groups is rarely a catalog job. Bus layouts, VT ratios and signal wiring differ from site to site. This is how we handle that, with figures you can check.
-
We have seen many layouts. Over 144 delivered projects span 110kV, 66kV, 35kV and 10kV, from substations and hydropower to mines, PV plants and railways. No two customized solutions were identical.
-
Your signal list decides the I/O. All 12 digital inputs are user-defined, and rated values and I/O are fixed in hardware before shipping. Please list your requirements in the order remarks, because they cannot be changed in the field.
-
Customization happens on our own line. Boards pass SMT with AOI inspection, wave soldering and a second AOI check. Then the CPU is programmed and the unit assembled in our Yueqing plant.
-
Every unit is aged before it ships. Each device runs 72 hours under power, then goes through component life checks, a withstand-voltage test and a short-circuit check. Final inspection confirms time synchronization within 2 seconds.
-
Housing changes are possible for volume orders. Tooling a new case is costly, so we take appearance customization when quantities justify it.
-
We stay involved after delivery. OEM/ODM, project integration, technical support and after-sales service are available. The warranty is 2 years from arrival of the goods.
-
We have been doing this since 1992. More than 70 patents and software copyrights back our protection technology.
Certifications & Standards




Testing evidence
- Type tests at the KETOP Laboratory, the national relay protection and automation equipment testing center
- IEC-TC95 international standard testing
- IEC 60255 / IEC 61850 related type-test reports
Management and market access
- ISO 9001, CCC and CE certificates
- State Grid qualified supplier since 2018
Standard-setting work
- National standard for 35kV and below standardized relay protection devices (drafting participant)
- NB/T 11054-2023 (anti-islanding protection)
- NB/T 11483-2024 (urban rail transit AC power relay protection)
- NB/T 11480-2024 (smart substation outdoor cabinet environmental control)
Company standing
- National high-tech enterprise, and national-level specialized and innovative enterprise (2023)
- National Torch Program industrialization project unit
- Council member of the relay protection and automation branch of the China Electrical Equipment Industry Association since 2006
Project References

Our track record covers medium-voltage distribution in many industries. These are company-level references, not specific to the NR-623.
- Power and heat: Shanxi Lanxian Fengda coking waste-heat power project (66kV); Inner Mongolia Kailu 66kV/10kV transition substation
- Mining and metals: Fukang Xigou coal mine substation (10kV); Anhui Shengxin Aluminium 35kV distribution
- Public works: Xining Wusi Avenue underpass distribution (10kV); Jinan Longshan relay pump station (35kV)
- Manufacturing: Yongjia Qiaoxia toy production base 35kV user substation
- Distributed PV: Huzhou Renxiang 5.4 MWp rooftop; Changxing Bingfeng 4 MWp; Dongying Guangrao 3.2 MW
- Landmarks: Haixinsha Square opening ceremony power supply, 16th Asian Games (2010); Three Gorges Yunyang reservoir; Yongtaiwen high-speed railway
FAQ
Q1: What is a Voltage Transformer Paralleling Protection Relay?
It is a relay in the PT cabinet that watches the bus voltage from two VT groups and protects against abnormal voltage. It also lets the two groups be paralleled. The NR-623 is NAHO's model for this job.
Q2: How is the NR-623 different from the NR-623A?
The NR-623 handles two VT groups with paralleling. The NR-623A covers one VT group with monitoring and protection only.
Q3: Which networks is it designed for?
10kV and below small-current grounding systems. The same hardware family serves substations, hydropower, distributed PV, industry and mining, and rail.
Q4: Which protections are included?
Over-voltage, under-voltage and zero-sequence over-voltage, each set to alarm or trip. Insulation monitoring, wire-break self-check and fault recording are included too.
Q5: How flexible are the I/O and rated values?
Rated values and digital I/O are customized in hardware at our factory and fixed before shipment, so state them when ordering. You define what each of the 12 inputs does.
Q6: How does it connect to my SCADA?
Through RS-485 or Ethernet (optional), using Modbus, 101 or 103.
Q7: What does it need to run?
AC/DC 85–265V or DC48V auxiliary power, 100V rated voltage and 50Hz.
Q8: What do you need from me to quote?
Voltage level, number of VT groups, rated values, power supply, I/O list, communication needs, panel cut-out size and quantity.
Q9: What are the MOQ and warranty?
The MOQ for the NR-620 series is 20 units. The warranty is 2 years from arrival.
Q10: Can you support OEM/ODM and provide documents?
Yes, we provide OEM/ODM, project integration, technical support and after-sales service. Send your project requirements and we will confirm which drawings and test support apply.
Get a Quote

Tell us your project, and we will configure the NR-623 to fit.
Send your VT group count, rated values, I/O list, communication needs and quantity. Our engineers will reply with a matching configuration for your Voltage Transformer Paralleling Protection Relay requirement.