VT Paralleling Control Device NR-623

VT Paralleling Control Device NR-623

Custom-engineered VT paralleling control device for 10kV and below PT cabinets, tailored to your grid code and panel layout.
Two VT groups (3-phase + U0 each)
12 digital inputs
4 dry-contact outputs
Modbus / IEC 60870-5-101 / 103
RS-485 / Ethernet (optional)
Built and tested in our own factory
Send Inquiry
Description

NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of vt paralleling control device nr-623 in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.

 

Overview

 

 

NH12-2

 

The NR-623 is a microprocessor-based VT monitoring, protection and paralleling device. It belongs to the NR-620 series, which is designed for 10kV and below small-current grounding systems. It is built for the PT cabinet, the point where bus voltage is measured, and where two VT groups must be monitored and paralleled when the bus is split.

The NR-623 measures two independent VT groups, each with three phase voltages plus zero-sequence voltage (U0). On this input it provides over-voltage, under-voltage and zero-sequence over-voltage protection, bus insulation monitoring and PT wire-break self-check. It also performs PT paralleling and records faults. Over-voltage, under-voltage and zero-sequence over-voltage can each be set to alarm or trip.

 

It suits panel builders and EPC teams working on 10kV and below distribution. Wiring is straightforward: 12 digital inputs, 4 dry-contact outputs and standard SCADA protocols. If your project uses only a single VT group, the sister model NR-623A covers one-group monitoring and protection.

We design and manufacture the NR-623 ourselves in Yueqing, Zhejiang. Rated values and digital I/O can be fixed to your project drawings before production.

product-1265-949

 

 

Key Features & Protection Functions

  • product-1200-800

    Voltage protection

    • Over-voltage protection: alarm or trip

    • Under-voltage protection: alarm or trip

    • Zero-sequence over-voltage protection: alarm or trip

  • product-1200-900

    Bus and VT supervision

    • Bus insulation monitoring
    • PT wire-break self-check

    • PT paralleling for two VT groups

     

    Recording and I/O

    • Fault recording for post-event analysis

    • 12 digital inputs, with user-defined input functions

    • 4 dry-contact outputs

  • product-1265-949

    Communication

    • RS-485 or Ethernet (optional)
    • Modbus, IEC 60870-5-101 and 103 protocols

     

    Hardware

    • Wide-range power supply: AC/DC 85–265V or DC48V

    • Standard 149 × 188 mm front panel with a 139 × 159 mm cut-out

 

 

Technical Specifications

 

Category

Parameter

NR-623

Application

Cabinet type

PT cabinet with two VT groups (monitoring and paralleling)

Application

System

10kV and below, small-current grounding, NR-620 series

Measurement

Voltage channels

2 × (3-phase + U0)

Measurement

Rated voltage / frequency

100V / 50Hz

Measurement

Rated current

5A (1A on request)

Functions

Voltage protection

Over-voltage, under-voltage, zero-sequence over-voltage; each set to alarm or trip

Functions

Supervision

Bus insulation monitoring; PT wire-break self-check

Functions

Paralleling and recording

PT paralleling; fault recording

I/O

Digital inputs

12, functions defined by the user

I/O

Digital outputs

4 dry contacts

Communication

Port

RS-485 / Ethernet (optional)

Communication

Protocols

Modbus, 101, 103

Power

Auxiliary supply

AC/DC 85–265V, or DC48V

Environment

Temperature / humidity / pressure

−30 to +55 °C / ≤95% non-condensing / 80–110 kPa

Mechanical

Front panel

149 × 188 mm

Mechanical

Depth / cut-out

108 mm / 139 × 159 mm (±0.5)

 

Air around the device must be free of acid, alkali or explosive substances.

 

Applications

 

 

The NR-623 is a PT-cabinet device, so it fits wherever a 10kV and below bus is supplied through two VT groups. NAHO supplies relays across five scenario groups.

 

product-1264-711
  • Substations
    Bus voltage monitoring in PT cabinets on 10kV and below distribution busbars. The device supervises both VT groups and parallels them when needed.

  • Hydropower
    Voltage monitoring and zero-sequence supervision in station auxiliary and generator-side medium-voltage cabinets.

product-1672-940
  • Distributed PV
    PT cabinets at the point where a PV plant connects to a 10kV and below system, where bus voltage supervision and insulation monitoring are needed.

  • Industrial & Mining
    PT cabinets in plant and mine distribution rooms, where insulation monitoring helps detect grounding faults in small-current grounding systems.

product-1246-701
  • Rail & Transportation
    PT cabinets in traction-related and station-level medium-voltage distribution.

 

 

How It Works

 

 

Signal Acquisition

Both VT groups feed three phase voltages and the zero-sequence voltage U0 to the device. The 12 digital inputs bring in breaker and bus-tie states, and their functions can be defined by the user.

Protection Logic

The processor evaluates the voltage signals against the over-voltage, under-voltage and zero-sequence over-voltage settings. It also runs bus insulation monitoring and the PT wire-break self-check.

Fault Judgment

When a setting is exceeded, the device decides whether to alarm or trip, according to how that function was configured. If a VT wire-break is detected, it flags the abnormal input.

Output And Record

The 4 dry-contact outputs send the alarm or trip command to your panel. The paralleling function acts on the two VT groups. Fault recording stores the event, and RS-485 or Ethernet (optional) reports it to the SCADA system over Modbus, 101 or 103.

 

 

Why Choose NAHO: Custom Engineering Capability

 

product-1267-1027

A PT cabinet with two VT groups is rarely a catalog job. Bus layouts, VT ratios and signal wiring differ from site to site. This is how we handle that, with figures you can check.

  • We have seen many layouts. Over 144 delivered projects span 110kV, 66kV, 35kV and 10kV, from substations and hydropower to mines, PV plants and railways. No two customized solutions were identical.

  • Your signal list decides the I/O. All 12 digital inputs are user-defined, and rated values and I/O are fixed in hardware before shipping. Please list your requirements in the order remarks, because they cannot be changed in the field.

  • Customization happens on our own line. Boards pass SMT with AOI inspection, wave soldering and a second AOI check. Then the CPU is programmed and the unit assembled in our Yueqing plant.

  • Every unit is aged before it ships. Each device runs 72 hours under power, then goes through component life checks, a withstand-voltage test and a short-circuit check. Final inspection confirms time synchronization within 2 seconds.

  • Housing changes are possible for volume orders. Tooling a new case is costly, so we take appearance customization when quantities justify it.

  • We stay involved after delivery. OEM/ODM, project integration, technical support and after-sales service are available. The warranty is 2 years from arrival of the goods.

  • We have been doing this since 1992. More than 70 patents and software copyrights back our protection technology.

 

 

Certifications & Standards

 

product-1221-1628
product-1268-1711
product-1267-1710
product-1268-1711

Testing evidence

  • Type tests at the KETOP Laboratory, the national relay protection and automation equipment testing center
  • IEC-TC95 international standard testing
  • IEC 60255 / IEC 61850 related type-test reports

 

Management and market access

  • ISO 9001, CCC and CE certificates
  • State Grid qualified supplier since 2018

 

Standard-setting work

  • National standard for 35kV and below standardized relay protection devices (drafting participant)
  • NB/T 11054-2023 (anti-islanding protection)
  • NB/T 11483-2024 (urban rail transit AC power relay protection)
  • NB/T 11480-2024 (smart substation outdoor cabinet environmental control)

 

Company standing

  • National high-tech enterprise, and national-level specialized and innovative enterprise (2023)
  • National Torch Program industrialization project unit
  • Council member of the relay protection and automation branch of the China Electrical Equipment Industry Association since 2006

 

 

Project References

 

product-1279-1336

Our track record covers medium-voltage distribution in many industries. These are company-level references, not specific to the NR-623.

  • Power and heat: Shanxi Lanxian Fengda coking waste-heat power project (66kV); Inner Mongolia Kailu 66kV/10kV transition substation
  • Mining and metals: Fukang Xigou coal mine substation (10kV); Anhui Shengxin Aluminium 35kV distribution
  • Public works: Xining Wusi Avenue underpass distribution (10kV); Jinan Longshan relay pump station (35kV)
  • Manufacturing: Yongjia Qiaoxia toy production base 35kV user substation
  • Distributed PV: Huzhou Renxiang 5.4 MWp rooftop; Changxing Bingfeng 4 MWp; Dongying Guangrao 3.2 MW
  • Landmarks: Haixinsha Square opening ceremony power supply, 16th Asian Games (2010); Three Gorges Yunyang reservoir; Yongtaiwen high-speed railway

 

 

FAQ

 

Q1: What is a Voltage Transformer Paralleling Protection Relay?

It is a relay in the PT cabinet that watches the bus voltage from two VT groups and protects against abnormal voltage. It also lets the two groups be paralleled. The NR-623 is NAHO's model for this job.

Q2: How is the NR-623 different from the NR-623A?

The NR-623 handles two VT groups with paralleling. The NR-623A covers one VT group with monitoring and protection only.

Q3: Which networks is it designed for?

10kV and below small-current grounding systems. The same hardware family serves substations, hydropower, distributed PV, industry and mining, and rail.

Q4: Which protections are included?

Over-voltage, under-voltage and zero-sequence over-voltage, each set to alarm or trip. Insulation monitoring, wire-break self-check and fault recording are included too.

Q5: How flexible are the I/O and rated values?

Rated values and digital I/O are customized in hardware at our factory and fixed before shipment, so state them when ordering. You define what each of the 12 inputs does.

Q6: How does it connect to my SCADA?

Through RS-485 or Ethernet (optional), using Modbus, 101 or 103.

Q7: What does it need to run?

AC/DC 85–265V or DC48V auxiliary power, 100V rated voltage and 50Hz.

Q8: What do you need from me to quote?

Voltage level, number of VT groups, rated values, power supply, I/O list, communication needs, panel cut-out size and quantity.

Q9: What are the MOQ and warranty?

The MOQ for the NR-620 series is 20 units. The warranty is 2 years from arrival.

Q10: Can you support OEM/ODM and provide documents?

Yes, we provide OEM/ODM, project integration, technical support and after-sales service. Send your project requirements and we will confirm which drawings and test support apply.

 

Get a Quote

 

product-1269-952

Tell us your project, and we will configure the NR-623 to fit.

Send your VT group count, rated values, I/O list, communication needs and quantity. Our engineers will reply with a matching configuration for your Voltage Transformer Paralleling Protection Relay requirement.

Get a Quote

 

Hot Tags: vt paralleling control device nr-623, China vt paralleling control device nr-623 manufacturers, suppliers, factory