NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of vt protection device nr-613a in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.
Overview

A PT cabinet with one voltage-transformer set needs a protection device focused on voltage conditions and the integrity of its own sensing circuit-not on bus-tie switching or feeder overcurrent. NAHO manufactures the NR-613A VT Protection Device for this specific arrangement in small-current grounding systems rated 10kV and below.
The unit takes three-phase voltage and U0 measurements to support overvoltage, undervoltage and zero-sequence overvoltage protection. It also provides busbar insulation monitoring, a PT disconnection self-check and fault recording. These functions help a panel designer bring voltage supervision and PT-related fault indications together in one microprocessor-based device. The listed output behavior for its voltage protection functions is alarm or trip, subject to the selected protection scheme.
In its documented configuration, the NR-613A has ten digital inputs, five dry-contact outputs and a 485 communications interface supporting the listed Modbus/101/103 protocols. It belongs to the NR-610 family, but its intended use is narrower than that of other family members: one PT set in a PT cabinet. NAHO can manufacture project-specific rated values and digital I/O arrangements when the requirements are confirmed before the order is placed. These hardware changes are not field-configurable after delivery.

Key Features & Protection Functions
-

Voltage Supervision
- Overvoltage: Identifies excessive monitored voltage; alarm or trip response.
-
Undervoltage: Detects voltage below the specified operating criterion; alarm or trip response.
-
Zero-Sequence Overvoltage: Uses residual-voltage supervision for abnormal system conditions; alarm or trip response.
-

PT-Circuit Condition Checks
- Single-Set PT Monitoring: Intended for one PT group, rather than a two-PT parallel arrangement.
-
PT Disconnection Self-Check: Provides an indication when the monitored PT circuit is disconnected.
-
Busbar Insulation Monitoring: Adds a separate supervision function for the connected busbar.
-

Signals and Records
- Three-phase voltage plus U0 input channels.
-
Ten digital inputs and five dry-contact outputs in the listed model configuration.
-
Fault recording for subsequent event review.
-
485 communications; protocol options listed as Modbus/101/103.
Technical Specifications
|
Parameter |
NR-613A Information |
|
Device Category |
Microprocessor-based VT protection and monitoring device |
|
Intended PT Arrangement |
One set of voltage transformers in a PT cabinet |
|
Applicable System |
Small-current grounding; 10kV and below |
|
Voltage Input Channels |
Three-phase voltage + U0 |
|
Digital Inputs |
10 |
|
Contact Outputs |
5 dry contacts |
|
Communication Interface |
485 |
|
Listed Communication Protocols |
Modbus / 101 / 103 |
|
Voltage Protection |
Overvoltage; undervoltage; zero-sequence overvoltage (alarm or trip) |
|
Other Supervision |
Busbar insulation; PT disconnection self-check |
|
Event Function |
Fault recording |
|
Operating Supply (NR-610 Series Data)* |
AC/DC 85–265V, DC 48V or DC 24V |
|
Rated Voltage (NR-610 Series Data)* |
100V |
|
Rated Frequency (NR-610 Series Data)* |
50Hz |
|
Temperature (NR-610 Series Data)* |
−30°C to +55°C |
|
Humidity (NR-610 Series Data)* |
≤95%, non-condensing |
|
Atmospheric Pressure (NR-610 Series Data)* |
80–110kPa |
|
Front Panel |
128 × 168mm |
|
Side-View Overall Depth |
108mm |
|
Rear Housing |
122 × 141mm |
|
Cabinet Cutout |
123 ±0.5mm × 143 ±0.5mm |
The starred operating and rated values appear under the supplied NR-610 series conditions; they should be checked against the final NR-613A order configuration. The dimensional figures are from the NR-613A drawing. The source does not disclose specific protection setting ranges or field-editable thresholds.
Applications

-
Substations - One-PT Voltage Supervision
For single-PT cubicles in 10kV-and-below distribution switchgear, where voltage status, PT disconnection and busbar insulation information must be monitored together.
-
Hydropower - Station Distribution PT Panels
A potential fit for the PT cabinet portion of a hydropower facility's compatible low- or medium-voltage distribution system; selection is based on the actual PT wiring and grounding arrangement.

-
Distributed PV - PT Monitoring at the Distribution Interface
Can be evaluated for a suitable single-PT cabinet on the distribution side of a solar installation. It is not presented here as a dedicated anti-islanding protection device.
-
Industrial & Mining - Dedicated Voltage-Transformer Cubicles
For plant electrical rooms and mining switchboards with a single PT set, where voltage abnormalities and sensing-circuit condition need clear indications.

-
Rail & Transportation - Auxiliary Distribution Equipment
For compatible PT panels within 10kV-and-below auxiliary power systems, subject to project electrical specifications; no traction-specific function is claimed.
How It Works
Acquire PT Voltage
The device receives three-phase voltage and U0 signals from the connected single PT arrangement.
Evaluate Voltage Criteria
Internal protection functions assess overvoltage, undervoltage and zero-sequence overvoltage conditions.
Check Related Abnormalities
PT disconnection self-check and busbar insulation monitoring provide additional supervision, while fault information can be recorded.
Deliver The Specified Response
For the supported voltage protection elements, the cabinet scheme uses the device's alarm or trip response and available dry-contact outputs. The actual wiring and actions must match the approved project design.
Why Choose NAHO - Single-PT Projects, Factory-Specified Hardware

-
One-PT Requirement, Identified at Selection
NR-613A is the one-set PT model. NR-613, by contrast, is the series model for two PT sets and their monitoring/parallel operation. This model distinction should be established before a panel bill of materials is finalized.
-
Ratings and I/O Agreed Before Manufacturing
NAHO states that rated parameters and digital I/O can be customized in hardware. The customer must specify these on the purchase order; they cannot be reconfigured by the customer afterward.
-
Production Steps That Can Be Checked
The documented process includes SMT and AOI, wave soldering, CPU programming, assembly, 72-hour powered aging, withstand and short-circuit checks, and outgoing inspection.
-
Known Procurement Terms
The company information lists an MOQ of 20 units for the NR-610 series and a two-year warranty calculated from arrival. Confirm applicability and commercial terms for the NR-613A quotation.
-
Company-Wide Engineering Context
NAHO traces its operations to 1992 and lists 144 power projects across multiple industries. Those references support its manufacturer background but are not proof of NR-613A installation in each project.
-
OEM/ODM Pathway
Project integration and technical support are available; external housing appearance changes are considered for sufficiently large orders because new moulds involve development costs.
Certifications & Standards




NAHO lists ISO 9001, CCC and CE documentation, KETOP laboratory type-test materials, and IEC 60255/IEC 61850-related testing in its company qualification information. It also reports participation in drafting the national technical requirements for standardized protection devices rated 35kV and below.
These are manufacturer-level qualifications. For a PT-cabinet tender, request the documents that expressly identify the proposed NR-613A configuration and verify the standards required by the project; do not assume that every company report certifies this particular model.
Project References
The following projects are selected from NAHO's company engineering list because they illustrate 10kV distribution or relevant power-industry environments.

- The records do not identify NR-613A as the device installed.
Qinghai Chenguang New Energy Substation - 10kV
- A 10kV substation reference relevant to the distribution voltage class of this device.
Guizhou Xifeng Shidong Switching Station - 10kV
- A switching-station example from the documented project list.
Anda Wastewater Treatment Plant Distribution Room - 10kV
- An industrial utility distribution reference.
Inner Mongolia Hohhot Zhonghuan Foundry - 10kV
- A manufacturing-facility power project.
FAQ
Q1: What is an NR-613A VT Protection Device?
It is NAHO's microprocessor-based unit for monitoring one PT set in a 10kV-and-below small-current grounding system. It combines voltage protection with PT-circuit and busbar supervision.
Q2: Why choose NR-613A instead of NR-613?
The distinction is the PT arrangement: NR-613A serves one set, whereas NR-613 is designated for two sets of PTs. Select according to the cabinet's actual VT/PT wiring.
Q3: Is it intended for a feeder breaker or for a PT cabinet?
The supplied model description designates NR-613A for a PT cabinet. Do not substitute it for a feeder or bus-tie protection device without a separate engineering review.
Q4: Which voltage abnormalities can it respond to?
Overvoltage, undervoltage and zero-sequence overvoltage are listed, each with alarm or trip functionality. The provided material does not publish numerical setting ranges.
Q5: Can it indicate a broken PT circuit?
Yes. PT disconnection self-check is among the documented functions, alongside busbar insulation monitoring.
Q6: How many signals and contacts does the standard listed configuration have?
It specifies three-phase plus U0 measurement, 10 digital inputs and five dry-contact outputs.
Q7: Which communication options are shown?
The supplied configuration names a 485 interface and Modbus/101/103 protocols. Confirm the exact protocol implementation for integration into your monitoring system.
Q8: Can the buyer change the I/O or rated values on site?
Not for hardware-customized parameters. NAHO requires rated-value and digital-I/O requirements before ordering; the customer cannot reconfigure that hardware after delivery. User-editable protection threshold ranges are not confirmed in the supplied documents.
Q9: What should I send for NR-613A selection and pricing?
Provide the single-line/PT wiring diagram, system and PT secondary voltage, grounding method, auxiliary supply, needed alarm/trip actions, input/output allocation, communications protocol, panel cutout and required quantity.
Q10: Are OEM production, drawings and testing documents available?
NAHO offers OEM/ODM and technical support. Request the model-specific mechanical/wiring drawings and available test documents during engineering review; the supplied materials do not establish an exact document package for every order.
Get a Quote

Send Your Single-PT Cabinet Requirements to the Manufacturer
Have a PT cubicle drawing or a voltage-supervision specification? Send it to NAHO with the operating voltage, PT arrangement, I/O list and proposed quantity. We can review the factory configuration required for VT Protection Device NR-613A and prepare a quotation.
Hot Tags: vt protection device nr-613a, China vt protection device nr-613a manufacturers, suppliers, factory