Incomer Automatic Bus Transfer Relay NR-611

Incomer Automatic Bus Transfer Relay NR-611

Factory-built incomer automatic bus transfer relay for 10kV and below dual-supply incomer cabinets, with customizable digital inputs and rated current.
Send Inquiry
Description

NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of incomer automatic bus transfer relay nr-611 in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.

 

Overview

 

 

NH5-2

 

The NR-611 is a microcomputer-based incomer automatic bus transfer relay designed for incomer cabinet protection and automatic supply switching in small-current grounding systems rated 10kV and below. It protects the incoming feeder and, when the working supply is lost, switches to the standby supply and recovers afterwards, so downstream loads are not left exposed to a prolonged outage.

NR-611 belongs to the NR-610 series, which shares one hardware platform across several cabinet types. Within the series, NR-611 is the model for two-way incoming supply protection and automatic switching. It combines three-phase plus Ix current sampling with two independent three-phase three-wire voltage inputs, ten digital inputs and five dry-contact outputs. Built-in supervision covers PT and CT circuit failure, busbar insulation and the operating circuit, and fault recording is included.

 

Every NR-611 is manufactured and tested in our own factory in Yueqing, Zhejiang. It is offered as a standard unit, and digital inputs, rated current and (for volume orders) enclosure design can be tailored to your panel and grid requirements.

product-1265-949

 

 

Model Description (NR-610 Series)

 

 

Model

Application

NR-610

Incomer and feeder cabinets

NR-611

Two-way incoming supply protection and automatic switching

NR-612

Section switch protection and automatic switching

NR-613

PT cabinet: monitoring and paralleling of two PT groups

NR-613A

PT cabinet: monitoring and protection of one PT group

NR-614

Motor cabinet

 

 

Key Features & Protection Functions

 

  • product-1200-800

    Protection Functions

    • Three-section overcurrent protection with directional lockout (complex voltage lockout) - ANSI 50/51, 67

    • Inverse time-limit overcurrent protection - ANSI 51

    • Negative-sequence overcurrent protection - ANSI 46

    • Three-section zero-sequence overcurrent protection and inverse time-limit zero-sequence overcurrent - ANSI 50N/51N

    • Overcurrent / zero-sequence overcurrent post-acceleration

    • Overload protection (alarm or trip)

    • Overvoltage protection (alarm or trip) - ANSI 59

    • Undervoltage protection (alarm or trip) - ANSI 27

    • Zero-sequence overvoltage protection (alarm or trip) - ANSI 59N

  • product-5712-4284

    Automatic Transfer Function

    • Automatic switching and automatic recovery of the incoming power supply - ANSI 83

     

    Measurement Functions

    • 3-phase + Ix current protection/measurement channel

    • 2 × (3-phase, 3-wire) voltage measurement channels

  • product-1265-949

    Communication Functions

    • RS-485 communication port

    • Modbus / IEC 60870-5-101 / IEC 60870-5-103 protocol support

     

    Self-Diagnostic & Monitoring Functions

    • Busbar insulation monitoring

    • PT failure detection (ANSI 60FL)

    • CT circuit failure detection

    • Operating circuit self-check

    • Fault recording

    • 10-way digital input (customizable); 5-way dry-contact digital output

 

Which model for which cabinet? NR-611 is the choice when an incomer cabinet is fed from two supplies and needs protection plus automatic switching in one device. For a single incomer or feeder, see NR-610. For section-switch transfer, see NR-612.

 

 

Technical Specifications

 

Parameter

Specification

Applicable Scope

Small-current grounding systems, 10kV and below; two-way incomer cabinet protection and automatic switching

Rated Voltage

100V

Rated Frequency

50Hz

Rated Current

5A, 1A (customized)

Auxiliary Power Supply

AC/DC 85V–265V; DC 48V; DC 24V

Current Protection/Measurement Channel

3-phase + Ix

Voltage Measurement Channel

2 × (3-phase, 3-wire)

Digital Input

10-way (customizable)

Digital Output

5-way dry contacts

Communication Port

RS-485

Communication Protocol

Modbus / IEC 60870-5-101 / IEC 60870-5-103

Installation

Flush-mounted (panel mounting)

Operating Temperature

-30℃ ~ +55℃

Relative Humidity

≤95%, non-condensing

Atmospheric Pressure

80–110kPa

Test Standard Atmospheric Condition

15℃~35℃, 45%~75% RH, 86~106kPa

Dimensions

128mm (W) × 188mm (H) × 108mm (D); body depth 90mm

Panel Cutout

123±0.5mm (W) × 143±0.5mm (H)

Compliance

Type-tested at the KETOP Laboratory (National Relay Protection & Automation Equipment Quality Inspection Center); IEC-TC95 international standard testing

 

Ambient air must be free of conductive dust, corrosive gas or explosive substances, and the installation site should be protected from rain and snow.

 

 

Applications

 

 

modular-1
  • Dual-supply incomer cabinets (10kV and below)
    Protection and automatic switching for incoming cabinets fed from two independent supplies, in distribution rooms and substations.

modular-2
  • Substation and distribution-station incoming bays
    Incomer-bay protection with built-in PT/CT supervision and busbar insulation monitoring, reducing the number of separate devices in the cabinet.

modular-3
  • Industrial users with dual-circuit supply
    Plants in mining, steel and chemical industries, where the incoming supply must be protected and restored automatically after a supply loss.

 

How It Works

 

Signal Acquisition

NR-611 samples three-phase current plus the Ix auxiliary current channel, and two independent three-phase three-wire voltages, one for each incoming supply.

Supervision

The device continuously checks PT and CT circuits, busbar insulation and the operating circuit, so abnormal sampling conditions are identified before they cause a wrong decision.

Protection And Supply-Status Judgement

Overcurrent, zero-sequence, negative-sequence, overload and voltage protection run on the incoming supply, while the two voltage inputs and the Ix channel provide the information used to judge the state of each supply.

Action And Recording

The device trips or alarms through its dry-contact outputs, executes automatic switching and recovery of the incoming supply, records the fault waveform, and reports status through RS-485 using Modbus, IEC 101 or IEC 103.

 

 

Why Choose NAHO - Built Around Your Project, Not Our Catalog

 

product-1267-1027

We are the factory, not a trading intermediary. NAHO has been building electrical equipment since 1992, when our predecessor, Dachang Electric, started in Liushi, Yueqing. Every NR-611 is made and tested at our own plant.

 

What a factory-built relay means for you

  • In-house production line: SMT placement with AOI inspection, wave soldering, CPU programming, assembly and commissioning are all done under one roof.
  • 72-hour burn-in: each unit is aged for 72 hours under 24V / 48V / 220V power, followed by component-life check, withstand-voltage test and short-circuit check.
  • Two-stage outgoing inspection: manual re-commissioning plus appearance checks (panel, rear cover, screws, printing, clock synchronization within 2 seconds, lens) before packing and shipmen.

 

 

Customization we can actually deliver

  • Digital inputs: the 10 digital inputs are user-definable to match your cabinet wiring.
  • Rated current: 5A or 1A, selected to match your CT configuration.
  • Enclosure and panel design: available for volume orders, because the tooling investment is justified once order volume supports it.
  • OEM/ODM, project integration, technical support and after-sales service from the same team.

 

  • Proof from the field: 144+ engineering references from 10kV to 110kV, across 11+ provinces in China, in power, mining, steel, chemical, construction and transportation, and distributed PV projects up to 10.96606 MW.
  • Order terms: MOQ for the NR-610 series (including NR-611) is 20 units. Warranty is 2 years from the date of arrival.
product-900-643

 

 

Certifications & Standards

 

product-1221-1628
product-1268-1711
product-1267-1710
product-1268-1711
  • Type testing: all products type-tested at the KETOP Laboratory (National Relay Protection & Automation Equipment Quality Inspection Center)
  • International standard: tested to IEC-TC95 international standards
  • Standards drafting: participant in drafting the national standard for 35kV-and-below standardized protection devices (2019, 2021) and the energy industry standards NB/T 11054-2023 (Anti-islanding Protection Devices), NB/T 11483-2024 (Relay Protection for Urban Rail AC Power Supply Systems) and NB/T 11480-2024 (Environmental Control Systems for Smart Substation Outdoor Control Cabinets)
  • State Grid qualified supplier (since 2018)
  • Management and product certificates: ISO 9001, CCC, CE, IEC 60255 / IEC 61850 related certificates
  • Enterprise status: National High-tech Enterprise (2013), National "Specialized, Refined, Distinctive and Innovative" enterprise (2023), 70+ patents and software copyrights

 

 

Case Studies / Project References

 

The references below are NAHO platform projects across the voltage range and industries we serve. They show the scope of our engineering experience and are not specific NR-611 installations.

 

product-1200-1600

Featured projects:

  • Opening Ceremony Power Supply Protection, Haixinsha Square, 16th Asian Games (2010)
  • Three Gorges Yunyang Reservoir Area Project

 

Project quick reference

 

Project (anonymized)

Region

Voltage

Industry

Substation project

Kashgar, Xinjiang

110kV

Power

Cement plant substation

Zhangye, Gansu

110kV

Building materials

Gold mine distribution room renovation

Jilin

66kV

Mining

District heating plant main step-down station

Yanji, Jilin

66kV / 6kV

Heating / Utility

Chemical plant substation

Shandong

35kV

Chemical

Aluminium plant distribution project

Anhui

35kV

Metallurgy

Coal mine substation

Datong, Shanxi

35kV / 6kV

Mining

Expressway construction substation

Guizhou

35kV / 10kV

Transportation

Tobacco logistics center distribution station

Zunyi, Guizhou

35kV

Logistics

Special steel plant

Baotou, Inner Mongolia

10kV

Steel

Copper-molybdenum mine Phase II distribution

Inner Mongolia

10kV

Mining

Rooftop distributed PV project

Zhejiang

10.96606 MW

Distributed PV

 

 

FAQ

 

Q1: What is an incomer automatic bus transfer relay?

It is a protection device installed in an incomer cabinet that protects the incoming supply and automatically switches to a standby supply when the working supply is lost, then recovers when conditions allow. The NR-611 combines both functions in one microcomputer-based relay.

Q2: Where is the NR-611 used?

In incomer cabinets of small-current grounding systems rated 10kV and below, especially where two independent supplies feed one bus: distribution rooms, substation incoming bays, and industrial plants with dual-circuit supply.

Q3: Can the NR-611 be used for a single-supply incomer or feeder cabinet?

For a single incomer or feeder cabinet we recommend NR-610 from the same series. NR-611 is intended for two-way incoming supply protection and automatic switching.

Q4: What protection functions does the NR-611 provide?

Three-section overcurrent with directional lockout, inverse time-limit overcurrent, negative-sequence overcurrent, three-section zero-sequence overcurrent with inverse time-limit, post-acceleration, overload (alarm or trip), and over/under/zero-sequence voltage protection, plus automatic switching and recovery of the incoming supply.

Q5: Can the digital I/O or rated current be customized?

Yes. The 10 digital input channels can be user-defined, and the rated current can be set to 5A or 1A depending on your CT configuration.

Q6: Which communication protocols are supported?

RS-485 with Modbus, IEC 60870-5-101 and IEC 60870-5-103.

Q7: What self-diagnostic functions does it include?

PT failure detection, CT circuit failure detection, busbar insulation monitoring, operating-circuit self-check and fault recording.

Q8: What information is required for a quote or selection?

Project name and location, system voltage and frequency, application type, required protection functions, communication protocol, CT secondary rating, quantity, and any customization requirements.

Q9: Do you provide OEM/ODM customization, and what is the MOQ?

Yes. We offer OEM/ODM, and custom enclosure design is available for volume orders. The MOQ for the NR-610 series, including NR-611, is 20 units.

Q10: Can you provide technical drawings, wiring diagrams and testing support?

Yes. We provide technical documents and support during selection, commissioning and operation, and a 2-year warranty from the date of arrival.

 

Get a Quote

 

product-1269-952

Tell us about your project and we will reply within 24 hours.

  • Project name & location
  • System voltage & frequency
  • Application type (dual-supply incomer cabinet / substation incoming bay / industrial plant)
  • Required protection functions
  • Communication protocol needs
  • CT secondary rating (5A / 1A)
  • Quantity (MOQ 20 units for NR-610 series)
  • Customization requirements (digital I/O, enclosure/panel, OEM/ODM)

 

Request a Quote

 

Hot Tags: incomer automatic bus transfer relay nr-611, China incomer automatic bus transfer relay nr-611 manufacturers, suppliers, factory