NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of bus-tie automatic transfer protection relay nr-622 in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.
Overview

NR-622 is a numerical protection and control relay in the NR-620 series, made for substations that take power from two incoming lines and split the busbar with a bus-tie breaker. It is the device you fit when one relay has to watch both the incomer side and the tie.
Two-source layouts exist so that a dead supply does not mean a dead busbar. NR-622 supports that goal in a single housing. It gives directional overcurrent and zero-sequence earth-fault protection. It also gives automatic standby-source switching and bus-tie switching. Insulation monitoring, PT and CT disconnection checks and fault recording come with the same unit. Fewer add-on relays mean a simpler cabinet and a shorter wiring list.
The relay is intended for 10kV and below small-current grounding systems. It accepts AC/DC 85–265V or DC48V supply, and it talks to your SCADA over RS-485 or optional Ethernet.
We assemble and test it ourselves, so rated current and digital I/O are set to your drawing before production starts.

Key Features & Protection Functions
-

Source transfer
- Standby power auto-switch, with automatic return when the main source recovers
-
Bus-tie (sectionalizing) breaker auto-switch
-
Designed for two-way incomer cabinets and bus-tie cabinets
-

Phase-fault and overload protection
- Three-stage overcurrent, with compound-voltage blocking and a directional element
-
Inverse-time overcurrent
-
Overload, selectable as alarm or trip
-
Post-acceleration
Earth-fault protection
- Three-stage zero-sequence overcurrent
- Inverse-time zero-sequence overcurrent
-

Supervision
- Busbar insulation monitoring
- PT disconnection and CT disconnection self-check
-
Operation circuit self-check
-
Fault waveform recording
Configuration and communication
-
User-defined digital input functions
-
Built-in operation box
-
RS-485 or Ethernet (optional); Modbus, IEC 60870-5-101, IEC 60870-5-103
Technical Specifications
|
Parameter |
NR-622 |
|
Product type |
Bus-tie automatic transfer protection relay |
|
Series |
NR-620 |
|
Applicable system |
10kV and below, small-current grounding |
|
Suited cabinets |
Two-way incomer and bus-tie cabinets |
|
Current inputs |
2 phase currents + 2 Ix |
|
Voltage inputs |
2 × (three-phase, three-wire) |
|
Digital inputs |
12 |
|
Digital outputs |
6 dry contacts |
|
Communication ports |
RS-485 / Ethernet (optional) |
|
Protocols |
Modbus / IEC 60870-5-101 / IEC 60870-5-103 |
|
Auxiliary power |
AC/DC 85–265V, DC48V |
|
Rated voltage |
100V |
|
Rated frequency |
50Hz |
|
Rated current |
5A or 1A (customizable) |
|
Operating temperature |
-30°C to +55°C |
|
Relative humidity |
≤95%, no condensation |
|
Atmospheric pressure |
80–110kPa |
|
Front panel (W × H) |
149 × 188 mm |
|
Depth |
108 mm (90 mm body) |
|
Panel cutout (W × H) |
139 ± 0.5 × 159 ± 0.5 mm |
|
Warranty |
2 years from delivery |
Installation note: the air around the relay must not contain acid, alkali, corrosive or explosive substances, and the site needs lightning, rain and snow protection.
Applications

-
Substations
Two-source 10kV and below substations that need coordinated incomer and tie protection. -
Hydropower
Station-service and plant distribution boards fed from more than one source. Our automation work includes the Three Gorges Yunyang reservoir area project.

-
Distributed PV
Distribution rooms where PV output and grid supply meet at a split busbar. Our largest PV reference is 10.96606 MW. -
Industrial & Mining
Process plants that cannot afford a full shutdown when one feeder is lost: metallurgy, chemical, textile, paper and mining. Our records include coal mines, gold mines, steel and foundry sites.

-
Rail & Transportation
Traction-adjacent and infrastructure distribution. We helped draft NB/T 11483-2024 for rail transit relay protection and have supplied the Yongtaiwen high-speed railway.
How It Works
Signal Acquisition
The relay reads phase currents and Ix from the tie CTs, two sets of three-phase voltage from the two bus sections, and up to 12 digital inputs such as breaker status.
Protection Logic
Signals feed the overcurrent, zero-sequence and overload functions. At the same time, PT/CT disconnection checks and insulation monitoring verify that the inputs are trustworthy, which helps avoid false operation on a bad signal.
Fault And Transfer Decision
On a fault, the relay selects trip. On loss of an incoming source, it starts the standby-source or bus-tie switching sequence. The operation circuit self-check confirms the breaker control path is healthy.
Command And Record
Dry contacts issue the trip or close command. The waveform is stored, and data go to your monitoring system over RS-485 or Ethernet.
Why Choose NAHO - Custom Engineering Capability

We manufacture the relay ourselves. That is why we can accept requirements a catalog product cannot meet. Each point below can be checked.
-
144+ customized projects on record.
They range from substations to mines, steel works, chemical plants, transport and PV sites. The wide range itself shows that non-standard requests are routine for us. -
Four voltage classes: 10kV, 35kV, 66kV and 110kV.
Your voltage level has almost certainly been delivered by us before. -
Rated current and digital I/O are built to your order.
Choose 5A or 1A, and state your I/O requirement when ordering. We set the hardware at the factory. The unit cannot be reconfigured by the customer afterward, so we confirm details with you first. -
OEM/ODM, project integration, technical support and after-sales service.
Custom housing appearance is accepted for large-volume orders, since the tooling investment is high. -
A documented production route.
SMT with AOI inspection, plug-in assembly, wave soldering with visual check and repair, then AOI again. After that come CPU programming, assembly, initial adjustment, a 72-hour burn-in under 24V, 48V or 220V power, component-life check, withstand-voltage test and short-circuit check. Final inspection covers re-adjustment, appearance and time synchronization within 2 seconds. Units are stored twice before shipping. -
Since 1992, with standards experience.
We took part in drafting national and energy-industry standards, and hold 70+ patents and software copyrights. -
Order terms: MOQ 20 units for the NR-620 series; 2-year warranty from arrival.
Certifications & Standards




Documents available on request
- ISO 9001 quality management system
- CCC and CE certification
- IEC 60255 / IEC 61850 related type test reports
- KETOP Laboratory type test reports
- State Grid qualified supplier certificate (2018)
Company recognition
- National high-tech enterprise
- National-level "Specialized, Refined, Distinctive and Innovative" enterprise (2023)
- National Torch Program industrialization project unit
- Member and executive member unit, relay protection and automation equipment branch, China Electrical Equipment Industry Association (since 2006)
Standards we helped draft
- General technical requirements for standardized relay protection devices of 35kV and below (national standard)
- NB/T 11054-2023, anti-islanding protection devices
- NB/T 11483-2024, relay protection for urban rail transit AC power supply systems
- NB/T 11480-2024, environmental control systems for smart substation outdoor control cabinets
Our products have passed type tests at the KETOP Laboratory and IEC-TC95 international standard testing.
Project References
NR-622 belongs to the NR-620 platform. The projects below show our delivery record across voltage levels and industries.
|
Project |
Level / type |
|
Shandan Tieqi Cement substation, Zhangye, Gansu |
110kV |
|
Yanji heat source plant 66kV–6kV distribution, Jilin |
66kV–6kV |
|
Kailu 66kV/10kV transition substation, Inner Mongolia |
66kV/10kV |
|
Xing'ergou coal mine 35kV/6kV substation, Datong, Shanxi |
35kV/6kV |
|
Mashan 35kV/10kV distribution room, Guangxi |
35kV/10kV |
|
Tongzi highway 35kV construction substation, Zunyi, Guizhou |
35kV |
|
Hudong Heavy Machinery 35kV–6.3kV distribution, Shanghai |
35kV |
|
Xiaojiawan coal mine 10kV/6kV distribution, Panzhihua |
10kV/6kV |
|
Liyi Precision Manufacturing 10.96606 MW PV, Zhejiang |
Distributed PV |
|
Yongci 35kV 15.6 MW PV |
35kV |
Landmark work: 2010 Asian Games Haixinsha opening ceremony power protection, Three Gorges Yunyang reservoir area, Inner Mongolia wind farms, Yongtaiwen high-speed railway.
FAQ
Q1: What is a bus-tie automatic transfer protection relay?
It protects the bus-tie circuit between two bus sections and runs the logic that restores power by switching sources or closing the tie after a supply is lost. NR-622 is our unit for this task.
Q2: Where is the NR-622 used?
In two-way incomer and bus-tie cabinets at 10kV and below: substations, hydropower plants, PV distribution rooms, factories, mines and rail supply points.
Q3: Can this device be used in a small-current grounding system?
Yes. That is its design target, and zero-sequence protection and busbar insulation monitoring are included.
Q4: What protection functions does it provide?
Three-stage directional overcurrent with compound-voltage blocking, inverse-time overcurrent, overload alarm or trip, three-stage and inverse-time zero-sequence overcurrent, and post-acceleration. Transfer, insulation monitoring, PT/CT self-check, operation circuit self-check and fault recording are also included.
Q5: Can protection thresholds or digital I/O be customized?
Rated current and digital I/O are customized in the factory, so please give your requirements in the order notes. They cannot be changed by the customer later. Digital input functions can be user-defined.
Q6: What information do you need for a quote?
System voltage and grounding method, rated current, auxiliary supply, I/O counts, communication method and protocol, transfer scheme, single-line diagram if you have one, quantity and destination.
Q7: Do you provide OEM/ODM customization?
Yes, along with project integration, technical support and after-sales service. Custom appearance requires a large order volume.
Q8: Can you provide technical drawings, wiring diagrams and testing support?
Yes. The unit is 149 × 188 mm with a 139 × 159 mm (±0.5) cutout. Ask us for drawings, wiring diagrams and test support.
Q9: What are the MOQ and warranty?
20 units for the NR-620 series; 2 years from delivery.
Q10: Which certificates can you supply?
ISO 9001, CCC, CE, IEC 60255 / IEC 61850 related type test reports, KETOP Laboratory reports and the State Grid qualified supplier certificate.
Get a Quote

Planning a two-incomer lineup with a bus tie?
Send your voltage level, rated current, I/O list and single-line diagram. We will confirm the NR-622 configuration and quote.
NAHO ELECTRIC POWER TECHNOLOGY CO., LTD.
No. 15 Zhengtai Road, Xinguang Industrial Zone, Liushi, Yueqing, Zhejiang
Hot Tags: bus-tie automatic transfer protection relay nr-622, China bus-tie automatic transfer protection relay nr-622 manufacturers, suppliers, factory