NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of automatic bus transfer protection relay nr-631 in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.
Overview

NR-631 is a numerical Incomer Bus Transfer Relay that protects an incoming cubicle and manages the changeover between two power sources, for networks up to 66kV with a small-current grounding neutral. It is the dual-source model of the NAHO (NRUICN) NR-630 series.
Its purpose is to keep the busbar energized. Two separate three-phase voltage inputs track the main and standby feeders. If one source fails, or a fault appears on the incomer, NR-631 clears it, brings in the other source, and can switch back once the first one returns.
The NR-630 platform adds a 4.3-inch color screen (or digital tube display), 12 inputs, 12 dry-contact outputs and two temperature/humidity channels, so the same unit doubles as the cubicle's local display and monitor. Order the standard configuration, or have us customize the I/O logic, rated current and, on larger orders, the panel and housing.

Key Features & Protection Functions
Protection Functions
|
Function |
ANSI Reference* |
|
Three-stage overcurrent, voltage-blocked and directional |
50/51, 67 |
|
Inverse-time overcurrent |
51 |
|
Negative-sequence overcurrent |
46 |
|
Three-stage zero-sequence overcurrent |
50N/51N |
|
Inverse-time zero-sequence overcurrent |
51N |
|
Overload, alarm or trip |
49/51 |
|
Overvoltage and undervoltage, alarm or trip |
59 / 27 |
|
Acceleration after closing |
- |
|
Standby source auto-transfer and auto-recovery |
83 |
*For selection reference. Please confirm against your project specification.
-

Measurement Functions
- Phase currents Ia, Ib, Ic plus an auxiliary current Ix
-
Two sets of three-phase voltage, one for each source
-
100V, 50Hz; 5A current input, 1A on request
-

Communication Functions
- RS-485 / Ethernet
-
Modbus, IEC 60870-5-101, IEC 60870-5-103
Monitoring Functions
- Busbar insulation monitoring
-
PT and CT wire-break self-check, operation circuit self-check
-
Fault waveform recording
-
Two-channel temperature and humidity monitoring
-
Built-in operation box; 12 user-defined inputs
-

Which NR-630 Series Model Fits Which Panel?
-
NR-630: incoming and feeder cubicles
-
NR-631: two-source incomer cubicles with automatic transfer (this page)
-
NR-632: sectionalizing switch protection and automatic transfer
-
NR-633: PT cubicles, monitoring and paralleling of two PT groups
-
Technical Specifications
|
Parameter |
Specification |
|
Applicable Network |
Small-current grounding, 66kV and below |
|
Rated Voltage / Frequency |
100V / 50Hz |
|
Rated Current |
5A (1A customizable) |
|
Analog Inputs |
3-phase current + Ix; 2 × 3-phase 3-wire voltage |
|
Auxiliary Supply |
AC/DC 85–265V or DC 48V |
|
Binary I/O |
12 user-definable inputs / 12 dry-contact outputs |
|
Communication |
RS-485 / Ethernet; Modbus, IEC 60870-5-101/-103 |
|
Display |
Digital tube or 4.3-inch color screen |
|
Mounting |
Panel mounting, installed directly on switchgear |
|
Environment |
-30°C to +55°C; ≤95% RH, non-condensing; 80–110 kPa |
|
Dimensions |
Front 175 × 195 mm; depth 108 mm (90 mm behind panel) |
|
Compliance |
KETOP Laboratory type tests; IEC-TC95 testing |
Air at the site must be free of corrosive or explosive substances, and the installation must be protected from lightning, rain and snow.
Applications

-
Substations: dual-feed incomers that must keep the busbar live.
-
Hydropower: station-service and auxiliary supply panels.

-
Distributed PV: incoming and grid-side panels at C&I rooftop plants.
-
Industrial & Mining: two-circuit supply for mines, steel, chemical and textile plants.

-
Rail & Transportation: distribution rooms along rail lines and highways.
How It Works
In a dual-source cubicle, the Incomer Bus Transfer Relay follows four steps:
Sense
Current, Ix, both source voltages and 12 breaker/interlock inputs are sampled.
Evaluate
Values are compared with your protection settings while PT, CT and operation circuits are self-checked.
Decide
The relay chooses between alarm, trip and transfer, depending on the fault and the state of each source.
Act
Outputs open the faulty incomer and close the standby path, the event is recorded, and data goes to your SCADA over RS-485 or Ethernet.
Why Choose NAHO: Built Around Your Project, Not Our Catalog

- Since 1992: from Dachang Electric in Liushi, Yueqing, to three decades in power automation.
- 144+ customized projects from 10kV to 110kV across 11+ provinces, with PV projects up to 10.96606 MW.
- In-house production: SMT with AOI, wave soldering, 72-hour burn-in, withstand-voltage and short-circuit tests, then hand re-tuning and appearance inspection before shipping.
- Custom scope: OEM/ODM, project integration, technical support and after-sales service; custom enclosures for large-volume orders, since tooling cost needs volume to pay off.
-
Terms: MOQ 10 units for the NR-630 series; 2-year warranty from arrival.
Certifications & Standards




- KETOP Laboratory type tests (National Relay Protection and Automation Equipment Quality Inspection and Testing Center) and IEC-TC95 testing
- Drafting participant: national standard for 35kV and below protection devices; NB/T 11054-2023, NB/T 11483-2024, NB/T 11480-2024
- State Grid qualified supplier (2018)
- National high-tech enterprise; national "specialized, refined, distinctive and innovative" enterprise
- 70+ patents and software copyrights
Project References
NAHO company-level projects showing our engineering range.
|
Project |
Location |
Voltage |
|
Coking plant waste-heat power generation |
Lanxian, Shanxi |
66kV |
|
District heating plant main step-down distribution |
Yanji, Jilin |
66kV / 6kV |
|
Cement plant substation |
Shandan, Gansu |
110kV |
|
Coal mine substation |
Datong, Shanxi |
35kV / 6kV |
|
Rooftop distributed PV |
Zhejiang |
10.96606 MW |
FAQ
Q1: What is an Incomer Bus Transfer Relay?
A relay in the incoming cubicle that protects the line and busbar and moves the load to a second source when the main one is lost.
Q2: Where is NR-631 used?
In dual-source incomer cubicles up to 66kV, such as substations, mines, steel and chemical plants, and distribution rooms.
Q3: Can it be used for a two-way incoming power supply?
Yes. It monitors both sources with separate voltage inputs, transfers to the standby, and can return to the original source automatically.
Q4: What protection functions does it provide?
Directional voltage-blocked overcurrent, inverse-time overcurrent, zero- and negative-sequence overcurrent, overload, over/undervoltage and acceleration after closing.
Q5: Can I define the I/O or change the rated current?
All 12 inputs are user-definable, and rated current can be 5A or 1A. Output logic can be tailored to your project.
Q6: What do you need for a quote?
System voltage, rated current, auxiliary supply, communication requirement, I/O list, cut-out size and quantity.
Q7: Do you offer OEM/ODM?
Yes. Custom enclosure and panel design is available for large orders. NR-630 series MOQ is 10 units.
Q8: Can you provide drawings, wiring diagrams and test support?
Yes. Our engineers assist with selection, wiring and commissioning, backed by a 2-year warranty.
Get a Quote

Send us your panel drawing, and we'll fit the relay to it.
Share your voltage level, rated current, I/O list and quantity, and our engineers will reply with a selection and quotation.
Hot Tags: automatic bus transfer protection relay nr-631, China automatic bus transfer protection relay nr-631 manufacturers, suppliers, factory