NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of Multifunction Capacitor Bank Protection Relay in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.
Overview

The NR-500C is a multifunction capacitor bank protection relay designed for shunt capacitor banks in non-effectively grounded or ungrounded systems rated 110kV and below. It combines protection, measurement, control and fault recording in one device, so a capacitor cabinet is covered by a single platform.
The relay can be installed in a centralized relay panel or mounted locally in the switchgear cabinet. It supports distribution automation systems, and it includes a built-in operation box with trip/close self-holding and anti-pumping, which simplifies cabinet wiring.
NAHO has designed and manufactured protection and automation relays since 1992 in Yueqing, Zhejiang. We build the NR-500C in our own factory, and every product series goes through type testing at the KETOP Laboratory. The NR-500C is available as a standard model or customized to your project: rated voltage, rated current, digital I/O and operation box options can all be adjusted to your capacitor cabinet design.

Key Features & Protection Functions
-

Protection Functions
-
Instantaneous overcurrent protection
-
Time-delayed overcurrent (definite-time) protection
-
Overcurrent protection
-
Overvoltage protection
-
Undervoltage protection
-
Unbalance voltage protection
-
Unbalance current protection
-
-

Self-Supervision Functions
- PT disconnection self-check
-
CT disconnection self-check
-
Operation circuit self-check
-
Device fault self-check
Measurement Functions
-
3-phase current for protection
-
3-phase current for measurement
-
Unbalance current input
-
3-phase voltage measurement
-
Unbalance voltage input
-

Control & Monitoring Functions
-
Built-in operation box: trip/close self-holding and anti-pumping
-
16 digital inputs
-
14 digital outputs
-
Fault recording
Communication Functions
-
1 × RS-485 port as standard
-
Optional: 2 × RS-485 ports, or 2 × Ethernet ports
-
Technical Specifications
|
Parameter |
Specification |
|
Model |
NR-500C |
|
Applicable Scope |
Shunt capacitor bank protection and control in non-effectively grounded or ungrounded systems, 110kV and below |
|
Rated Voltage |
100V; 400V (customized) |
|
Rated Frequency |
50Hz |
|
Rated Current |
5A; 1A (customized) |
|
Auxiliary Power Supply |
AC/DC 110V or AC/DC 220V; DC 48V |
|
Current Protection/Measurement Channels |
3-phase protection + 3-phase measurement + unbalance current |
|
Voltage Measurement Channels |
3-phase + unbalance voltage |
|
Digital Inputs |
16 |
|
Digital Outputs |
14 |
|
Communication Ports |
1 × RS-485 as standard; optional 2 × RS-485 or 2 × Ethernet |
|
Operation Box |
Yes (trip/close self-holding, anti-pumping) |
|
Protection Functions |
Instantaneous overcurrent, time-delayed overcurrent, overcurrent, overvoltage, undervoltage, unbalance voltage, unbalance current |
|
Self-Supervision |
PT disconnection, CT disconnection, operation circuit, device fault |
|
Fault Recording |
Yes |
|
Installation |
Centralized relay panel or local switchgear mounting |
|
Operating Temperature |
-30℃ ~ +55℃ |
|
Relative Humidity |
≤95%, non-condensing |
|
Atmospheric Pressure |
80–110kPa |
|
Test Standard Atmospheric Condition |
+15℃ ~ +35℃, 45% ~ 75% RH, 86 ~ 106kPa |
|
Ambient Air Requirement |
Free of acidic or alkaline corrosive and explosive substances; lightning, rain and snow protection facilities required |
|
Dimensions (front panel) |
156mm (W) × 232mm (H) |
|
Depth |
198mm overall / 171mm body |
|
Rear View |
136mm × 210mm |
|
Panel Cutout |
approx. 138mm (W) × 212mm (H) |
|
Compliance |
Type-tested at the KETOP Laboratory; IEC-TC95 international standard testing |
Applications

-
Capacitor cabinets in substations
The NR-500C protects the shunt capacitor bank of a substation. It can be mounted locally in the capacitor cabinet or grouped in a central relay panel, for systems up to 110kV.

-
Shunt capacitor banks in distribution automation systems
The relay supports distribution automation systems. Its RS-485 and optional Ethernet ports allow the capacitor bank to be monitored and managed from your control room.

-
Industrial & distribution power systems
In mining, steel, chemical and other industrial plants, the NR-500C provides protection and control for capacitor banks in the plant's internal distribution system.
How It Works
Signal Acquisition
The relay reads three-phase current and voltage from the CT and PT, together with the unbalance current and unbalance voltage signals from the capacitor bank.
Protection Logic
The signals are compared in real time with the settings for instantaneous overcurrent, time-delayed overcurrent, overcurrent, overvoltage, undervoltage, unbalance voltage and unbalance current.
Fault Judgement
When a setting is exceeded, the relay confirms the fault and starts fault recording. PT and CT disconnection, operation circuit and device self-checks run continuously, so a faulty input or circuit is flagged and not mistaken for a capacitor bank fault.
Trip Command
The built-in operation box issues the trip command with self-holding and anti-pumping, and the digital outputs signal the event to your system.
Why Choose NAHO - Built Around Your Project, Not Our Catalog

Standard Products, Non-Standard Thinking
We are the manufacturer, not a trading company. Every NR-500C is built and tested in our own factory, and you deal directly with the people who build it.
- 30+ years of manufacturing experience. Our predecessor was founded in 1992 in Yueqing Liushi, and we have specialized in protection and power automation ever since.
- Adjustable at the parameter level. On the NR-500C you can specify rated voltage (100V or 400V), rated current (5A or 1A), digital I/O, operation box options and the communication configuration (1 or 2 × RS-485, or 2 × Ethernet) to match your cabinet design.
- Custom enclosure and panel design. We accept customized appearance for large-volume orders, because the tooling investment is justified once your volume supports it.
- Full-process support. OEM/ODM customization, project integration, technical support and after-sales service.
- Proven across 144+ projects. Our reference list spans 110kV down to 10kV and covers substations, mining, steel, chemical, transport and distributed PV (up to 10.96606 MW in a single project), across more than 11 provinces.
Factory quality control you can verify
- Automated SMT placement with AOI inspection
- Through-hole assembly and wave soldering, followed by visual inspection, touch-up and a second AOI inspection
- CPU board programming, then assembly
- Commissioning, then a 72-hour burn-in on 24V / 48V / 220V power, followed by component life checks, withstand voltage testing and short-circuit checks
- Final inspection: manual re-commissioning, appearance check (panel, rear cover, screws, printing, time synchronization within 2 seconds, lens)
- Packing and shipment
Ordering terms: MOQ is 10 units for the NR-500C. Standard warranty is 2 years from the date of arrival.

Certifications & Standards




- Type testing: all NAHO product series are type-tested by the National Relay Protection and Automation Equipment Quality Inspection & Testing Center (KETOP Laboratory).
- International standard testing: passed IEC-TC95 international standard testing.
- National standard drafting: participated in drafting the national standard for general technical requirements of standardized protection devices for 35kV and below (in 2019 and 2021).
- Industry standard drafting: NB/T 11054-2023 Technical Specification for Anti-islanding Protection Devices; NB/T 11483-2024 Technical Specification for Relay Protection of AC Traction Power Supply Systems in Urban Rail Transit; NB/T 11480-2024 Technical Specification for Environmental Control Systems of Outdoor Control Cabinets in Smart Substations.
- State Grid qualified supplier (since 2018).
- High-tech enterprise and national-level "Specialized, Refined, Distinctive and Innovative" enterprise (2023).
- 70+ patents and software copyrights.
Project References
These are NAHO protection and automation projects in related industries. The table shows the breadth of our delivery experience across voltage levels and sectors.
|
Project |
Voltage Level |
Industry |
|
Xinjiang Hash Tarilega 110kV construction substation |
110kV |
Construction power |
|
Shandan Tieqi Cement 110kV substation, Zhangye, Gansu |
110kV |
Cement / building materials |
|
Chunlong 110kV substation, Jinta County, Jiuquan |
110kV |
Industrial power |
|
Fengda Coking waste-heat power project, Lanxian, Shanxi |
66kV |
Coking / power generation |
|
Haigou Gold Mine 66kV distribution room renovation, Jilin |
66kV |
Mining |
|
Kailu 66kV/10kV transition substation, Inner Mongolia |
66kV/10kV |
Utility |
|
Liaocheng aluminum plant 35kV substation, Shandong |
35kV |
Metallurgy |
|
Tiecheng Mining 35kV substation, Chengde, Hebei |
35kV |
Mining |
|
Tongzi–Zhengxi Expressway 35kV construction substation, Zunyi, Guizhou |
35kV |
Transportation |
|
Golmud Salt Lake 35kV substation, Qinghai |
35kV |
Chemical |
|
Yongci 35kV, 15.6MW distributed PV project |
35kV |
Photovoltaic |
|
Anda Wastewater Treatment Plant distribution room |
10kV |
Environmental engineering |
Landmark projects: protection and distribution for the opening ceremony power supply at Haixinsha Square (16th Asian Games, 2010), and the Three Gorges Yunyang reservoir area project.
FAQ
Q1: What is a multifunction capacitor bank protection relay?
It is a microprocessor-based device that protects a shunt capacitor bank. It trips on faults such as overcurrent, overvoltage, undervoltage, and voltage or current unbalance, while also measuring, controlling and recording faults. The NR-500C does all of this in one unit.
Q2: Where is the NR-500C used?
It is used for shunt capacitor banks in non-effectively grounded or ungrounded systems rated 110kV and below. It is typically installed in capacitor cabinets, either in a central relay panel or locally in the switchgear.
Q3: Can this relay be used in a capacitor cabinet?
Yes. Capacitor cabinet protection is the intended application of the NR-500C. For other feeders, ask us to recommend a more suitable model from our NR-3XX, NR-5XX or NR-6XX series.
Q4: What protection functions does the NR-500C provide?
Instantaneous overcurrent, time-delayed overcurrent, overcurrent, overvoltage, undervoltage, unbalance voltage and unbalance current protection. It also self-checks for PT disconnection, CT disconnection, operation circuit faults and device faults, and it records faults.
Q5: Can the rated values, digital I/O or operation box be customized?
Yes. Rated voltage can be 100V or 400V and rated current 5A or 1A. Digital I/O and operation box options can also be adjusted to your cabinet design.
Q6: What communication ports does it have?
One RS-485 port is standard. You can optionally specify two RS-485 ports or two Ethernet ports.
Q7: What information do you need for a quote or selection?
Project name and location, system voltage and frequency, rated CT/PT values, required protection functions, communication needs, quantity and any customization requirements. See the quote form below.
Q8: Do you provide OEM/ODM customization?
Yes. We offer OEM/ODM, project integration, technical support and after-sales service. Customized appearance is available for large-volume orders, since we need to invest in new tooling.
Q9: What are the MOQ and warranty?
The MOQ is 10 units, and the warranty is 2 years from the date of arrival.
Q10: Can you provide technical drawings, wiring diagrams and testing support?
Yes. Contact our engineers for dimensions, wiring and technical support for your project.
Get a Quote

Send us the following details and our engineers will reply within 24 hours:
- Project name & location
- System voltage & frequency
- Application type (substation capacitor cabinet / industrial distribution / other)
- Rated current and voltage (CT/PT) values
- Required protection functions
- Communication requirements (RS-485 / Ethernet)
- Quantity
- Customization requirements (rated values, I/O, operation box, appearance)
Hot Tags: multifunction capacitor bank protection relay, China Multifunction Capacitor Bank Protection Relay manufacturers, suppliers, factory