NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of numerical capacitor bank protection relay nr-500c in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.
Overview

The NAHO NR-500C is a numerical capacitor bank protection relay designed to protect and control shunt capacitor banks in non-directly-grounded or ungrounded systems rated 110kV and below. It is built for capacitor cabinet protection and can be installed centrally on a panel or locally in the switchgear cabinet. It fully supports power distribution integrated automation systems.
As a capacitor bank protection and control relay, the NR-500C combines three-phase current protection and measurement with dedicated unbalance current and unbalance voltage channels. Its protection set covers current quick-break, time-limited quick-break, overcurrent, overvoltage, undervoltage, voltage unbalance and current unbalance. A built-in operation box provides trip/close self-holding and anti-pumping. Continuous self-supervision of the PT, CT, operating circuit and the device itself, together with fault recording, helps keep faults from spreading.
The NR-500C is designed and manufactured at our own factory in Yueqing, Zhejiang, where NAHO has focused on power automation for more than 30 years. It is available in a standard configuration and in customized versions. You can specify rated voltage, rated current, digital I/O and operation box options to match your project, and fully customized enclosures are available for large-volume orders.

Key Features & Protection Functions
-

Protection Functions
-
Current quick-break (instantaneous) protection
-
Time-limited quick-break protection
-
Overcurrent protection
-
Overvoltage protection
-
Undervoltage protection
-
Voltage unbalance protection
-
Current unbalance protection
-
-

Measurement Functions
- Current channel: 3-phase protection + 3-phase measurement + unbalance current
-
Voltage channel: 3-phase + unbalance voltage
Communication Functions
-
1 RS-485 port as standard
-
Optional: 2 RS-485 ports or 2 Ethernet ports
-

Monitoring & Control Functions
-
16 digital inputs and 14 digital outputs
-
Operation box with trip/close self-holding and anti-pumping
-
Self-supervision: PT circuit, CT circuit, operating circuit and device fault
-
Fault recording
-
Technical Specifications
|
Parameter |
Specification |
|
Applicable Scope |
Shunt capacitor bank protection and control in non-directly-grounded or ungrounded systems, 110kV and below; capacitor cabinet protection |
|
Rated Voltage |
100V; 400V (customized) |
|
Rated Frequency |
50Hz |
|
Rated Current |
5A; 1A (customized) |
|
Auxiliary Power Supply |
AC/DC 110V or AC/DC 220V; DC 48V |
|
Current Protection/Measurement Channel |
3-phase protection + 3-phase measurement + unbalance current |
|
Voltage Measurement Channel |
3-phase + unbalance voltage |
|
Digital Input |
16-way |
|
Digital Output |
14-way |
|
Communication Port |
1 RS-485 as standard (optional 2 RS-485 or 2 Ethernet) |
|
Operation Box |
Trip/close self-holding, anti-pumping |
|
Installation |
Centralized panel mounting or local mounting in switchgear cabinet |
|
Operating Temperature |
-30℃ ~ +55℃ |
|
Relative Humidity |
≤95%, non-condensing |
|
Atmospheric Pressure |
80–110kPa |
|
Test Standard Atmospheric Condition |
15℃~35℃, 45%~75% RH, 86~106kPa |
|
Environmental Requirement |
The surrounding air must not contain acid, alkali, corrosive or explosive substances; lightning, rain and snow protection facilities required on site |
|
Dimensions |
Front panel 156mm (W) × 232mm (H); depth 198mm overall / 171mm body; rear 136mm × 210mm |
|
Panel Cutout |
Approx. 138mm (W) × 212mm (H) |
|
Compliance |
Type-tested at the KETOP Laboratory (National Relay Protection & Automation Equipment Quality Inspection and Testing Center); passed IEC-TC95 international standard testing |
Applications

-
Capacitor cabinets in substations and distribution rooms
The NR-500C provides protection and control for the capacitor cabinet in non-directly-grounded or ungrounded systems up to 110kV.

-
Shunt capacitor banks
It serves as a Numerical Capacitor Bank Protection Relay for shunt capacitor banks, with unbalance current and unbalance voltage channels dedicated to bank protection.

-
Industrial and mining distribution systems
It protects capacitor cabinets in in-plant distribution systems such as steel, chemical, mining and cement. It can be mounted centrally on a panel or locally in the cabinet and connects to integrated automation systems.
How It Works
Signal Acquisition
The relay samples three-phase current and voltage, plus unbalance current and unbalance voltage from the capacitor bank.
Protection Logic
The signals are evaluated against the configured protection functions: quick-break, time-limited quick-break, overcurrent, over/undervoltage and unbalance protection.
Fault Judgement
When a setting is exceeded, the relay judges the fault, records it with the fault recording function, and reports it locally and over its communication port.
Trip Command
The operation box issues the trip command with self-holding and anti-pumping, isolating the capacitor bank from the system. During normal operation, the relay's self-supervision keeps checking the PT, CT, operating circuit and the device itself.
Why Choose NAHO - Custom Engineering Capability
Standard Products, Non-Standard Thinking

Every capacitor bank project has its own layout, CT ratio and control scheme. NAHO is a factory, not a trading intermediary, so we adjust the product itself rather than just the paperwork.
- 30+ years of manufacturing experience. Our predecessor was founded in 1992 in Yueqing Liushi, and we have focused on power automation ever since.
- Customization you can verify. On the NR-500C, rated voltage can be set to 100V or 400V, rated current to 5A or 1A, and digital I/O and operation box options can be configured to your scheme.
- Custom enclosure and panel design. We accept large-volume customized enclosure orders. Enclosure tooling is a real development cost, so it is justified once your order volume supports it.
- Full-process service. We provide OEM/ODM customization, project integration, technical support and after-sales service.
- Proven across non-standard projects. NAHO has delivered solutions for 144+ projects across 110kV, 66kV, 35kV and 10kV, in 11+ provinces. Distributed PV projects reach up to 10.96606 MW per project.
Built In-House, Tested Before It Ships
Every unit goes through our own production line:
- Automated SMT placement with AOI inspection, manual through-hole insertion, wave soldering with visual inspection and AOI re-check
- First warehousing, then CPU board programming and assembly
- Initial commissioning, then 72-hour aging under 24V / 48V / 220V power
- Component life check, withstand voltage test and short-circuit check
- Factory inspection: manual full-unit re-commissioning and appearance inspection (panel, rear cover, screws, printing, time synchronization within 2 seconds, lens)
- Packaging, second warehousing and shipment
MOQ and warranty
- MOQ: 10 units for the NR-5XX series
- Warranty: 2 years, counted from arrival of goods

Certifications & Standards




- Type testing: all products type-tested at the KETOP Laboratory, the National Relay Protection and Automation Equipment Quality Inspection and Testing Center
- International standard: passed IEC-TC95 international standard testing
- Standards drafting: participated in drafting the national standard for general technical requirements of standardized relay protection devices for 35kV and below (2019 and 2021), and several energy-industry standards
- State Grid qualified supplier: admitted in 2018
- Intellectual property: 70+ patents and software copyrights
- Enterprise status: national high-tech enterprise and national-level "Specialized, Refined, Distinctive and Innovative" enterprise (2023)
Case Studies
The projects below are NAHO substation and distribution references from 110kV to 10kV across power, mining, cement and industrial sectors. They show the range of non-standard configurations NAHO has delivered, and are not capacitor-bank-specific projects.
|
Project (anonymized) |
Voltage Level |
Industry / Application |
|
Construction-power substation, Xinjiang |
110kV |
Construction power |
|
Substation, Jinta County, Jiuquan, Gansu |
110kV |
Industrial power supply |
|
Cement plant substation, Shandan, Zhangye, Gansu |
110kV |
Cement |
|
Gold mine distribution room refurbishment, Jilin |
66kV |
Mining |
|
Industrial zone substation refurbishment, Anshan, Liaoning |
66kV |
Industrial zone |
|
Transition substation, Kailu, Inner Mongolia |
66kV/10kV |
Utility distribution |
|
Coal mine substation, Datong, Shanxi |
35kV/10kV |
Mining |
|
Mining substation, Chengde, Hebei |
35kV |
Mining |
|
Data center distribution room, Baotou, Inner Mongolia |
35kV |
Data center |
|
Salt lake substation, Golmud, Qinghai |
35kV |
Chemical / mining |
|
Cement plant, Urad Front Banner, Inner Mongolia |
10kV |
Cement |
|
Coal mine substation, Huadian, Jilin |
10kV |
Mining |
FAQ
Q1: What is the NR-500C Numerical Capacitor Bank Protection Relay?
The NR-500C is a numerical protection and control device for capacitor banks. It protects capacitor cabinets in non-directly-grounded or ungrounded systems rated 110kV and below.
Q2: Where is the NR-500C used?
It is used in capacitor cabinets in substations and distribution rooms, and in industrial and mining distribution systems. It protects and controls shunt capacitor banks.
Q3: Can this device be used in ungrounded systems?
Yes. The NR-500C is designed for non-directly-grounded or ungrounded systems up to 110kV.
Q4: What protection functions does the NR-500C provide?
It provides current quick-break, time-limited quick-break, overcurrent, overvoltage, undervoltage, voltage unbalance and current unbalance protection. It also provides PT, CT, operating circuit and device self-supervision, and fault recording.
Q5: Can the rated current, rated voltage or digital I/O be customized?
Yes. Rated current can be 5A or 1A depending on your CT configuration, and rated voltage can be 100V or 400V. Digital I/O and the operation box can be configured to your scheme.
Q6: What information is required for a quote or selection?
Please send the project name and location, system voltage and frequency, required protection functions, communication needs, quantity and any customization requirements.
Q7: Do you provide OEM/ODM customization?
Yes. NAHO provides OEM/ODM customization, project integration, technical support and after-sales service. Customized enclosures are accepted for large-volume orders because of the tooling cost.
Q8: Can you provide technical support and drawings?
Yes. Contact us with your project details for dimension and cutout drawings, selection support and technical support.
Q9: What are the MOQ and warranty?
MOQ is 10 units. Warranty is 2 years from the arrival of goods.
Q10: Does the NR-500C work with integrated automation systems?
Yes. It can be installed centrally on a panel or locally in the switchgear cabinet and fully supports power distribution integrated automation systems. It communicates through 1 RS-485 port as standard, with 2 RS-485 or 2 Ethernet ports optional.
Get a Quote

Send us the following and we will reply within 24 hours:
- Project name and location
- System voltage and frequency
- Application type (capacitor cabinet / substation / industrial / mining)
- Required protection functions
- Communication needs
- Quantity
- Customization requirements (rated voltage/current, I/O, operation box, enclosure)
Hot Tags: numerical capacitor bank protection relay nr-500c, China numerical capacitor bank protection relay nr-500c manufacturers, suppliers, factory