NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of feeder management relay nr620 in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.
Why "Management," Not Just "Protection"?

A protection-only relay clears a fault and stops there - it doesn't tell a maintenance team whether the trip was caused by an actual line fault or by a failing PT/CT connection, and it can't report status upstream unless someone walks the panel. The NR-620 feeder management relay was built to close that visibility gap on 10kV-and-below incoming and outgoing cabinets: alongside its core overcurrent and voltage protection set, it runs continuous bus insulation monitoring, PT and CT wiring self-checks, and fault recording, then reports all of it over RS-485 or an optional Ethernet port to a dispatch or SCADA system.
The platform underneath the NR-620 supports four related roles: NR-621 for two-way incoming cabinets with automatic standby-source transfer and self-recovery, and NR-622 for two-way incoming and bus-tie cabinets with source-switching logic, NR-623 / NR-623A for PT cabinet monitoring (dual- or single-group), and NR-624 for motor protection. A panel builder standardizing on this hardware base can source incoming, bus-tie, PT-metering and motor-feeder cabinets from one relay family instead of qualifying separate product lines for each.

Scope Note: Automation logic such as source auto-switching, section-switch transfer and PT paralleling lives in the NR-622/623 variants - the standard NR-620 itself is a feeder/incoming protection-and-measurement unit and does not include those switching functions. See Section 5 for the exact functional boundary.
Series Line-Up
|
Model |
Function |
|
NR-620 |
Feeder management relay for incoming and outgoing cabinets |
|
NR-621 |
Two-way incoming cabinet protection with automatic standby-source transfer and self-recovery |
|
NR-622 |
Two-way incoming / bus-tie cabinet protection with switching logic |
|
NR-623 |
PT cabinet monitoring - dual-PT paralleling |
|
NR-623A |
PT cabinet monitoring - single PT group |
|
NR-624 |
Motor protection |
What's On Board (and What Isn't)
-

Core Protection
Three-section overcurrent with directional (complex-voltage) lockout; inverse-time overcurrent, selectable alarm or trip; three-section overload; three-section zero-sequence overcurrent with inverse-time option; overcurrent and zero-sequence post-acceleration; automatic reclosing; over- and under-voltage protection including zero-sequence overvoltage; negative-sequence overcurrent; non-electric quantity inputs.
Measurement
3-phase + I0 current channel; 3-phase + U0 voltage channel - the same continuous sampling that feeds both the protection logic and the monitoring layer below.
-

Monitoring & Self-Diagnostics - The "Management" Half Of The Relay
Bus insulation monitoring; PT disconnection self-check; CT disconnection self-check; operating-circuit self-check; fault recording; 12-way user-configurable digital input; 6-way dry-contact digital output.
Communication
RS-485, with Ethernet available as an option; Modbus / IEC 60870-5-101 / IEC 60870-5-103.
-

Deliberately Left Off The Standard NR-620 (Available On Other Family Members Instead)
PT paralleling, backup-power auto-switching and auto-recovery, section-switch auto-transfer, voltage phase-reversal detection, extended start-up timing, and locked-rotor (stall) protection - these sit on the NR-622/623/624 side of the platform.
Technical Specifications
|
Parameter |
Specification |
|
Applicable Scope |
Small-current grounding system, 10kV and below; incoming, feeder, transformer, motor and capacitor protection |
|
Rated Voltage / Frequency |
100V / 50Hz |
|
Rated Current |
5A or 1A (customized) |
|
Auxiliary Power |
AC/DC 85–265V; DC 48V; DC 24V |
|
Current Channel |
3-phase + I0 |
|
Voltage Channel |
3-phase + U0 |
|
Digital Input |
12-way, user-configurable |
|
Digital Output |
6-way dry contact |
|
Communication |
RS-485 / Ethernet (optional); Modbus / IEC 60870-5-101 / IEC 60870-5-103 |
|
Overall Dimensions |
149mm(W) × 188mm(H) × 108mm(D) |
|
Cutout |
139mm × 159mm (±0.5mm) |
|
Operating Temperature |
-30°C to +55°C |
|
Relative Humidity |
≤95%, non-condensing |
|
Atmospheric Pressure |
80–110kPa |
|
Reference Test Condition |
15–35°C, 45–75% RH, 86–106kPa |
|
Type Test |
KETOP Laboratory; IEC-TC95 |
Where It Fits on the Panel

- Incoming & feeder cabinets - the primary role for the standard NR-620
- Bus-tie / dual-incoming cabinets - handled by the NR-622 variant, not the base unit

- PT cabinets - dual- or single-group monitoring through NR-623 / NR-623A
- Motor protection panels - via NR-624

- Transformer and capacitor feeders - covered within the same voltage class as general-purpose protection
This is a 10kV-and-below feeder-level family; it is not positioned for high-voltage transmission protection, large hydropower or utility-scale PV inverter stations, or main-line rail transit - those sit with NAHO's higher-voltage platforms.
Manufacturing & Quality Traceability
Because a feeder management relay is only as trustworthy as its self-diagnostics, every NR-620 goes through the same eleven-step manufacturing and inspection sequence used across NAHO's protection-relay range:
SMT placement with AOI inspection → manual through-hole insertion → wave soldering with visual check, touch-up and a second AOI pass → first warehousing → CPU firmware programming → assembly → initial commissioning followed by 72-hour burn-in at 24V/48V/220V, component-life screening, dielectric withstand testing and short-circuit checks → final inspection (manual re-commissioning plus a six-point appearance check covering panel, rear cover, screws, printed markings, clock sync within 2 seconds, and lens) → packaging → second warehousing → shipment. This traceable record from the SMT line to the loading dock backs the standard 2-year warranty, counted from date of arrival.
Manufacturing & Quality Traceability
Because a feeder management relay is only as trustworthy as its self-diagnostics, every NR-620 goes through the same eleven-step manufacturing and inspection sequence used across NAHO's protection-relay range: SMT placement with AOI inspection → manual through-hole insertion → wave soldering with visual check, touch-up and a second AOI pass → first warehousing → CPU firmware programming → assembly → initial commissioning followed by 72-hour burn-in at 24V/48V/220V, component-life screening, dielectric withstand testing and short-circuit checks → final inspection (manual re-commissioning plus a six-point appearance check covering panel, rear cover, screws, printed markings, clock sync within 2 seconds, and lens) → packaging → second warehousing → shipment. This traceable record from the SMT line to the loading dock backs the standard 2-year warranty, counted from date of arrival.
Signal Path

The relay samples 3-phase + I0 current and 3-phase + U0 voltage continuously. In parallel, it runs its self-diagnostic checks - bus insulation, PT/CT wiring - so a wiring fault gets flagged rather than masquerading as a line fault. When a sampled value crosses its configured threshold for the set time, the protection logic confirms the fault type and issues the corresponding trip or alarm through the dry-contact outputs, logging the event and pushing status upstream via RS-485 or Ethernet to a dispatch/SCADA system.
Ordering, MOQ & Logistics
- Minimum order quantity: 20 units (same MOQ tier as NR-310 and NR-610).
- Trade terms: FOB / CIF available on request.
- Payment: T/T; other terms negotiable for qualified volumes.
- Lead time: confirmed at quotation based on quantity and customization.
- Packaging: individually boxed with protective foam, palletized for export.
- Warranty: 2 years from date of arrival.
- Customization: panel-matched enclosure and appearance changes accepted for qualifying order volumes, since custom tooling only pays off at scale.

Certifications & Standards Participation




Every NR-620 unit is type-tested by the National Relay Protection and Automation Equipment Quality Inspection Center (KETOP Laboratory) and to IEC-TC95 international standards, and carries ISO 9001, CCC and CE certification along with IEC 60255 / IEC 61850 type-test reports (English-language certificate scans available on request). NAHO has held State Grid qualified-supplier status since 2018 and 70+ patents and software copyrights.
NAHO also participates directly in setting the standards this equipment is measured against: as a council/standing-council member of the China Electrical Equipment Industry Association's Relay Protection and Automation Equipment branch since 2006, it has helped draft the national standard for 35kV-and-below standardized protection devices, the 2023 anti-islanding protection standard NB/T11054-2023, and the 2024 standards covering urban rail-transit AC power-supply protection and smart-substation outdoor control-cabinet environmental control.
Where It's Been Deployed

- 2010 16th Asian Games, Haixinsha Square opening-ceremony power-supply protection
- Three Gorges Yunyang reservoir-area engineering project
- Andá wastewater-treatment-plant distribution room - motor/pump-heavy load profile
- Xining Wusi Street underpass pumping-station distribution project
- Panzhihua Xiaojiawan coal-mine distribution project (10kV/6kV) - mining motor loads
- Inner Mongolia Kailu Town 66kV/10kV transition substation - dual-voltage tie-point configuration
- 144+ engineering deployments from 110kV down to 10kV across 11+ provinces, plus distributed PV projects up to 10.96606 MW in single-project capacity
FAQ
Q1: What makes the NR-620 a "management" relay rather than a plain feeder relay?
The bus insulation monitoring, PT/CT self-checks and fault recording running alongside its protection logic - these give a maintenance team visibility into wiring health, not just a trip/no-trip outcome, and report that status upstream over RS-485/Ethernet.
Q2: Can the NR-620 handle a bus-tie or dual-incoming cabinet on its own?
No - that's the NR-622's job. The NR-620 covers incoming/feeder cabinets; NR-622 shares the same hardware but adds source-switching logic for bus-tie and dual-incoming setups.
Q3: Does the base NR-620 include PT paralleling or automatic switching?
No. Those functions, along with phase-reversal detection and stall/extended-start protection, are reserved for the NR-622/623/624 variants - the standard unit is protection-and-measurement only.
Q4: Is Ethernet required, or can I use RS-485 only?
RS-485 is standard; Ethernet is an optional communication port for sites already networked for SCADA/dispatch reporting.
Q5: Can rated current, digital I/O or the communication port be customized?
Yes - rated current can be set to 5A or 1A per your CT ratio. The 12-way digital input and rated current can also be customized, but customization requirements must be specified and noted when placing the order, as these are hardware configurations and cannot be changed by the customer afterward. The communication port can be specified as RS-485-only or RS-485/Ethernet.
Q6: What's the MOQ, and is enclosure customization available?
20 units minimum. Enclosure and panel-layout customization is accepted for qualifying order volumes.
Q7: What do you need to prepare a quote?
Project name and location, system voltage/frequency, application type (feeder/bus-tie/PT/motor), required protection functions, communication protocol, quantity, and any customization requirements.
Q8: Can NAHO supply wiring diagrams and commissioning support?
Yes - dimensional drawings, wiring diagrams and commissioning support are available on request alongside after-sales service.
Get a Quote

Send NAHO's engineering team your project name and location, system voltage/frequency, the cabinet role (incoming, feeder, bus-tie, PT or motor), required protection functions, communication protocol needs (RS-485 or RS-485/Ethernet), order quantity, and any customization requirements - a project-specific quotation will follow.
Hot Tags: feeder management relay nr620, China feeder management relay nr620 manufacturers, suppliers, factory