NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of numerical line protection relay nr-610 in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.
What Problem Does the NR-610 Solve?
Panel builders working on 10kV-and-below switchgear often face the same headache: incoming lines, outgoing feeders and general distribution bays each seem to demand a slightly different relay, driving up SKU count and spare-parts complexity. The NR-610 numerical line protection relay was engineered to close that gap - a single hardware platform, sampling three-phase current and voltage continuously, that can be commissioned on-site as an incoming-line unit, a feeder unit, or a general-purpose protection device, with the enclosure (128mm × 168mm × 108mm, flush-mounted, 124mm × 143mm cutout) sized to slot into standard cabinet openings.
Five sibling models extend the same numerical core into more specialized roles: NR-611 (dual-incoming automatic transfer), NR-612 (section-switch automatic transfer), NR-613 / NR-613A (PT cabinet monitoring, dual- or single-group), and NR-614 (motor cabinet protection). All share identical communication interfaces and mounting footprints, so a switchgear line built around the NR-610 can add these variants later without re-tooling the panel.

Series Configuration
|
Model |
Configuration |
|
NR-610 |
Standard protection for incoming and outgoing lines |
|
NR-611 |
Dual-incoming power supply - protection with automatic transfer |
|
NR-612 |
Section-switch protection with automatic transfer |
|
NR-613 |
Dual PT-group monitoring and paralleling |
|
NR-613A |
Single PT-group monitoring and protection |
|
NR-614 |
Motor cabinet protection |
Protection Logic & Self-Diagnostics
-

The relay's ANSI-style logic set covers the fault conditions a feeder or incoming line typically encounters: three-stage overcurrent with complex-voltage directional lockout, negative-sequence overcurrent, high-current blocking trip, inverse-time overcurrent, selectable alarm/trip overload, three-stage zero-sequence overcurrent with inverse-time option, post-acceleration, automatic reclosing, and both over- and under-voltage protection (including zero-sequence overvoltage). Non-electric quantity inputs are also supported for auxiliary trip/alarm signals.
-

What sets the NR-610 line apart from lighter feeder relays is its self-diagnostic layer, running continuously in the background: bus insulation monitoring, PT and CT disconnection self-checks, and operating-circuit self-check, all logged alongside fault records so a maintenance team can distinguish an actual line fault from a sensing-circuit fault during commissioning or troubleshooting.
-

Measurement is handled through 3-phase + I0 current channels and 3-phase + U0 voltage channels. On the I/O side, the relay carries an RS-485 port with Modbus / IEC 60870-5-101 / IEC 60870-5-103 support, 10 user-configurable digital inputs, and 5 dry-contact outputs. Reserve-power automatic transfer, section-switch transfer and PT paralleling are available as automation add-ons depending on which model in the series is deployed.
Technical Specifications
|
Parameter |
Specification |
|
Applicable Scope |
Low-current grounding system, 10kV and below; incoming/outgoing line protection |
|
Rated Voltage / Frequency |
100V / 50Hz |
|
Rated Current |
5A or 1A (customized) |
|
Auxiliary Power |
AC/DC 85–265V; DC 48V; DC 24V |
|
Current Channel |
3-phase + I0 |
|
Voltage Channel |
3-phase + U0 |
|
Digital Input |
10-way, user-configurable |
|
Digital Output |
5-way dry contact |
|
Communication |
RS-485; Modbus / IEC 60870-5-101 / IEC 60870-5-103 |
|
Mounting |
Flush-mounted, panel-installed |
|
Overall Dimensions |
128mm(W) × 168mm(H) × 108mm(D) |
|
Cutout |
124mm(W) × 143mm(H) |
|
Operating Temperature |
-30°C to +55°C |
|
Relative Humidity |
≤95%, non-condensing |
|
Atmospheric Pressure |
80–110kPa |
|
Reference Test Condition |
15–35°C, 45–75% RH, 86–106kPa |
|
Type Test |
KETOP Laboratory; IEC-TC95 |
Built on a Traceable Production Line
A relay that trips a live 10kV feeder incorrectly is expensive twice over - once in downtime and once in customer trust - so the NR-610 goes through the same eleven-stage manufacturing and inspection flow NAHO applies across its protection-relay range:

- SMT placement with AOI (automated optical inspection)
- Manual through-hole component insertion
- Wave soldering, followed by visual inspection, touch-up soldering and a second AOI pass
- First warehousing checkpoint

- CPU firmware programming
- Assembly
- Initial commissioning, followed by 72-hour burn-in at 24V / 48V / 220V, component-life screening, dielectric withstand testing and short-circuit checks

- Final factory inspection - manual re-commissioning plus a six-point appearance check (panel, rear cover, screws, printed markings, clock synchronization within 2 seconds, lens)
- Packaging
- Second warehousing checkpoint
- Shipment
This sequence gives every unit a traceable record from SMT line to shipping dock, which is the basis for the relay's 2-year warranty counted from the date of arrival.
Applications
Incoming-Line Protection
Primary protection for incoming supply at 10kV and below.
Outgoing-Feeder Protection
Three-section overcurrent and zero-sequence coverage for feeder circuits.
General Switchgear Panels
One numerical relay handling multiple fault types where a bespoke logic build isn't justified.
Industrial Distribution Rooms
Mining, metallurgical, chemical, textile, papermaking and similar in-plant power systems, drawing on NAHO's broader deployment history in these sectors.
Transformer, motor and capacitor protection loads are technically supported by the relay's logic but are covered by dedicated series members (e.g., NR-614 for motor cabinets) rather than presented here as separate use cases.
Signal Path

Current and voltage are sampled continuously across the 3-phase + I0 / 3-phase + U0 channels. The onboard logic core compares each sample against the configured protection curves - overcurrent, zero-sequence, voltage, non-electric quantity - while running the self-diagnostic checks (PT/CT disconnection, bus insulation, operating circuit) in parallel. Once a threshold is confirmed for its set time, the relay applies any directional-lockout or post-acceleration logic, issues a trip or alarm through the dry-contact outputs, and writes the event to the fault record for retrieval over RS-485 / Modbus / IEC 101 / IEC 103.
Ordering, MOQ & Logistics
- Minimum order quantity: 20 units for the NR-610 (same MOQ tier as NR-310 and NR-620); NR-630 and the 5-series carry a 10-unit MOQ.
- Trade terms: FOB / CIF available on request.
- Payment: T/T; other terms negotiable for qualified volumes.
- Lead time: confirmed at quotation, based on quantity and customization scope.
- Packaging: individually boxed with protective foam, palletized for export.
- Warranty: 2 years from date of arrival.

Certifications & Standards Participation




The NR-610 carries the same qualification base as NAHO's wider protection-relay range: type-tested by the National Relay Protection and Automation Equipment Quality Inspection Center (KETOP Laboratory) and to IEC-TC95 international standards, with ISO 9001, CCC and CE certification plus IEC 60255 / IEC 61850 type-test reports. NAHO has been a State Grid qualified supplier since 2018 and holds 70+ patents and software copyrights.
Beyond product certification, NAHO sits as a council/standing-council member of the China Electrical Equipment Industry Association's Relay Protection and Automation Equipment branch (since 2006), and has participated in drafting national and energy-industry standards including the national standard for 35kV-and-below standardized protection devices, NB/T11054-2023 (anti-islanding protection), and the 2024 standards for urban rail-transit AC power-supply protection and outdoor control-cabinet environmental control at smart substations.
Track Record

- 2010 16th Asian Games, Haixinsha Square opening-ceremony power-supply protection system
- Three Gorges Yunyang reservoir-area engineering project
- Inner Mongolia wind farm and Ningbo–Taizhou–Wenzhou high-speed rail projects
- 110kV / 66kV / 35kV / 10kV voltage-class deployments across Xinjiang, Gansu, Inner Mongolia, Shandong, Shanxi, Shaanxi, Jiangxi, Guizhou, Yunnan, Hubei and Sichuan
- Distributed PV project experience across Anhui, Jiangsu, Zhejiang, Shandong and Hubei, with single-project capacity up to 10.96606 MW
FAQ
Q1: What exactly does "numerical line protection relay" mean for the NR-610?
It means the protection logic runs on a digital sampling and processing core rather than analog relay logic - the NR-610 continuously digitizes current and voltage, evaluates them against configurable curves, and issues trip/alarm decisions with the self-diagnostic checks described above running in parallel.
Q2: Is the NR-610 suitable for both incoming and outgoing lines, or do I need a different model for each?
The same NR-610 hardware handles either role - it's configured during commissioning, not by ordering a different SKU. Only the more specialized functions (dual-incoming transfer, PT monitoring, motor protection) require moving to a sibling model.
Q3: How is the NR-610 different from a standard feeder relay?
The added self-diagnostic layer - bus insulation monitoring, PT/CT disconnection self-check and operating-circuit self-check - is what distinguishes it from lighter-duty feeder relays, alongside the shared numerical core across the whole NR-61x series.
Q4: What's the difference between NR-610 and NR-611–NR-614?
NR-611 adds dual-incoming automatic transfer, NR-612 handles section-switch automatic transfer, NR-613/613A cover PT cabinet monitoring (dual or single group), and NR-614 is built for motor cabinet protection.
Q5: Can rated current or digital I/O be customized?
Yes - rated current can be set to 5A or 1A based on your CT ratio, and the 10-way digital input is user-configurable. Please indicate any customization requirements when ordering, as these are hardware configurations and cannot be adjusted by the customer after delivery.
Q6: What's the minimum order quantity, and can enclosures be customized?
MOQ is 20 units. Enclosure/appearance customization is accepted for qualifying order volumes, since tooling for a non-standard housing is only cost-effective at scale.
Q7: What communication protocols are supported?
RS-485 with Modbus, IEC 60870-5-101 and IEC 60870-5-103.
Q8: What do you need from me to issue a quote?
Project name and location, system voltage/frequency, whether the unit is for incoming or outgoing service, required protection functions, communication protocol, quantity, and any customization needs.
Get a Quote

Send over your project name and location, voltage/frequency, the line role (incoming or feeder), the protection functions you need, communication protocol requirements, order quantity, and any customization (digital I/O, rated current, enclosure) - NAHO's engineering team will turn around a project-specific quotation.
Hot Tags: numerical line protection relay nr-610, China numerical line protection relay nr-610 manufacturers, suppliers, factory