Transmission Line Relay NR-500L

Transmission Line Relay NR-500L

Custom-engineered transmission line relay for 110kV substations, built as an IEC 61850 protection relay to fit your grid code and panel layout.
Send Inquiry
Description

NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of transmission line relay nr-500l in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.

 

Introduction

 

 

6-NR500L

NR500L

The NR-500L is a digital transmission line relay engineered for protection, measurement and control of feeder lines, incoming power lines and section switches in arc-suppression-coil-grounded or ungrounded systems rated 110kV and below. It can be built into a centralized control panel or mounted locally on switchgear as part of a substation automation system.

As one of the highest-voltage models in NAHO's protection relay lineup, it's aimed at transmission-level applications where reliability and standardized communication matter most, making it a practical choice as an IEC 61850 relay for modern substation automation.

 

The standard configuration can be adjusted further - rated current (5A or 1A), rated voltage (100V or 400V), and CT/PT or panel dimensions can all be customized. It's a decision NAHO made early: rather than lock the platform to one spec and force every project to adapt around it, the engineering team treats 110kV protection as something that gets built around the substation, not the other way around.

product-4032-2268

 

 

Key Features & Protection Functions

 

The NR-500L combines protection, measurement, monitoring and IEC 61850-based communication in a single platform.

  • product-1200-800

    Protection Functions

    Current quick-break protection with directional lockout (sensitive angle -45°); time-limited quick-break protection with directional lockout (sensitive angle -45°); overcurrent protection with directional lockout (sensitive angle -45°); overload alarm; zero-sequence overcurrent protection with U0 and directional lockout (sensitive angle +120°); three-phase single-shot reclosing with voltage-check/synchro-check (10–30°); reclosing post-acceleration; low-frequency load shedding (two-section, low-voltage lockout, slip-frequency lockout); low-voltage load shedding (two-section); low-frequency protection; charging protection; overvoltage protection; low-voltage protection

  • product-1200-900

    Measurement Functions

    3-phase current protection/measurement channel + I0; 3-phase voltage measurement channel + U0

     

    Communication Functions

    Functions natively as an IEC 61850 Protection relay for substation automation integration; standard 2-channel RS-485 (expandable to 2-channel RS-485 and 2-channel and 1-channel IRIG-B Ethernet); Modbus / IEC 60870-5-101 / IEC 60870-5-103 protocol support

  • product-1265-949

    Monitoring Functions

    16-way digital input; 14-way digital output (dry contacts); operation box with trip/close self-hold and anti-jump protection; PT disconnection self-check; CT disconnection self-check; operating circuit self-check; fault recording

 

 

Technical Specifications

 

Parameter

Specification

Applicable Scope

Arc-suppression-coil-grounded or ungrounded systems, 110kV and below; protection, measurement and control for feeder lines, incoming lines and section switches

Rated Voltage

100V, 400V (customized)

Rated Frequency

50Hz

Rated Current

5A, 1A (customized)

Auxiliary Power Supply

AC/DC 110V or AC/DC 220V; DC 48V

Current Protection/Measurement Channel

3-phase + I0

Voltage Measurement Channel

3-phase + U0

Digital Input

16-way

Digital Output

14-way dry contacts

Communication Port

Standard 2 × RS-485 (optional 2 × Ethernet)

Communication Protocol

IEC 61850 / Modbus / 101 / 103

Operating Temperature

-30℃ ~ +55℃

Relative Humidity

≤95%, non-condensing

Atmospheric Pressure

80–110kPa

Test Standard Atmospheric Condition

15℃~35℃, 45%~75% RH, 86~106kPa

Compliance

KETOP Laboratory type test; IEC-TC95 international standard test

 

Applications

 

modular-1
  • 110kV & Below Substation Feeder Bays -   Incoming line and outgoing feeder protection, measurement and control
  • Section Switch Protection - Arc-suppression-coil-grounded or ungrounded distribution/transmission networks
modular-2
  • Substation & Distribution Automation Integration - As an IEC 61850 relay, the device connects natively over IEC 61850, while still supporting Modbus/101/103 for mixed-protocol environments
modular-3
  • Panel-Mounted Or Switchgear-Local Installation - Flexible deployment for both centralized control rooms and on-site switchgear

 

 

How It Works

 

Signal Acquisition

Current and voltage signals from the protected line (3-phase current + I0, 3-phase voltage + U0) are continuously sampled through the relay's measurement channels.

Protection Logic

The device compares real-time measurements against configured protection thresholds (overcurrent, zero-sequence, over/under-voltage, etc.), applying directional lockout logic where required.

Fault Judgment

When a threshold is exceeded, the relay evaluates fault direction and severity, coordinating with reclosing and post-acceleration logic to avoid unnecessary or unsafe trips.

Trip/Reclose Command

The relay issues a trip command through its operation box (with self-hold and anti-jump protection) or initiates automatic reclosing, while logging the event via fault recording for post-event analysis. Fault and status data are reported upstream over IEC 61850 for centralized substation monitoring.

 

 

Why Choose NAHO for a 110kV Transmission Line Relay

 

product-1267-1027

Participation in drafting corresponding voltage-level standards, deep familiarity with industry product regulations, enabling better understanding of customer needs

 

NAHO has participated in the drafting of national standards for 35kV and below standardized protection devices (participating twice, in 2019 and 2021). In recent years, NAHO has also participated in drafting two energy industry standards in 2024/2025: NB/T11483-2024 "Technical Specification for Relay Protection of AC Power Supply Systems for Urban Rail Transit" and NB/T11480-2024 "Technical Specification for Environmental Control Systems of Outdoor Control Cabinets in Smart Substations." These standards do not imply that the NR-500L is a product dedicated to rail transit applications; rather, they demonstrate that the same R&D team has continuously participated in formulating technical specifications for high-voltage and outdoor substation protection equipment.

 

Proven 110kV project track record - real-world quality validation for NAHO

 

Beyond the case described below, NAHO's 110kV-and-below engineering experience covers industrial retrofit projects (e.g., a 10kV-to-110kV upgrade project at a food factory in Zhengzhou), new substation construction (Xinjiang, Gansu), and capacity expansion/retrofit of existing grids (Chongqing) - giving NAHO combined new-build and retrofit project experience of the type typically required for 110kV protection projects.

Communication capability natively adapted for substation integration, not a retrofitted add-on - positioning the NR-500L as a true IEC 61850 Protection relay and reducing the need for future replacements: Native IEC 61850 support, with communication interfaces expandable from 1x RS-485 to 2x RS-485 or 2x Ethernet. The same device can be used with legacy SCADA systems or deployed in fully automated smart substations without any hardware replacement.

product-900-643

 

 

Certifications & Standards

 

product-1221-1628
product-1268-1711
product-1267-1710
product-1268-1711
  • Type-tested by the National Relay Protection and Automation Equipment Quality Inspection Center (KETOP Laboratory)
  • Tested to IEC-TC95 international standards
  • Participating drafter, national standard for 35kV-and-below standardized protection devices (2019, 2021)
  • Participating drafter, NB/T11054-2023 (anti-islanding protection, released Feb 2023, effective Aug 2023), NB/T11483-2024 (urban rail transit AC power protection), and NB/T11480-2024 (smart-substation outdoor cabinet environmental control)
  • Approved supplier for State Grid (qualified 2018)
  • 70+ patents and software copyrights across NAHO's protection and automation lines

 

 

Case Studies / Project References

 

 

product-1706-1279
  • Xinjiang Hashtari-lega 110kV Construction Substation
  • Jiuquan Jinta County Chunlong 110kV Substation
  • Zhangye Shandan Tieqi Cement 110kV Substation
  • Fuzhou Nancheng Shanshui Avenue 110kV Relocation Project
  • Zhengzhou Dali Foods 10kV-to-110kV Reconstruction & Expansion
  • Chongqing Ganshui Town Capacity-Increase Power Project

 

 

FAQ

 

Q1: What is the NR-500L?

The NR-500L is a digital transmission line relay designed for feeder, incoming line and section switch protection in 110kV-and-below systems with arc-suppression-coil-grounded or ungrounded neutral configurations.

Q2: Where is the NR-500L used?

In substation and distribution automation systems, either centrally grouped in control panels or mounted locally on switchgear.

Q3: Is the NR-500L an IEC 61850 relay?

Yes, natively - it integrates directly with modern substation automation systems, and also supports Modbus and IEC 60870-5-101/103 for legacy or mixed-protocol networks.

Q4: What protection functions does it provide?

Current quick-break, time-limited quick-break, overcurrent, zero-sequence overcurrent, overvoltage/low-voltage, low-frequency and low-voltage load shedding, three-phase reclosing with post-acceleration, and charging protection, among others.

Q5: Can the rated current or voltage be customized?

Yes - rated current can be customized to 5A or 1A, and rated voltage to 100V or 400V, depending on your CT/PT configuration.Please confirm any customization requirements before ordering, as these hardware configurations cannot be changed by the customer afterward.

Q6: Can the communication interface be expanded?

Yes - the standard configuration includes 1×RS-485, upgradeable to 2×RS-485 or 2×Ethernet depending on your network architecture.

Q7: What's the minimum order quantity?

10 units, in line with NAHO's standard MOQ for the NR-500 series.

Q8: What information is required for a quote?

Project name and location, system voltage and frequency, application type, required protection functions, communication protocol needs, quantity, and any customization requirements.

Q9: Do you provide OEM/ODM customization?

Yes - across the NR series, including project integration, technical support and after-sales service.

Q10: Can you provide technical drawings and testing support?

Yes - dimensional drawings, wiring diagrams and testing/commissioning support are available on request.

 

Get a Quote

 

product-1269-952

To receive an accurate quote, please provide:

  • Project name & location
  • System voltage & frequency
  • Application type (substation / PV / hydropower / industrial / rail...)
  • Required protection functions
  • Communication protocol needs
  • Quantity
  • Customization requirements (digital I/O, rated current, enclosure format, etc.)

 

Request a Quote

 

Hot Tags: transmission line relay nr-500l, China transmission line relay nr-500l manufacturers, suppliers, factory