NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of relay for feeder protection nr660a in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.
Introduction

The NR-660A relay for feeder protection is a microcomputer-based feeder protection relay for small-current grounding systems rated 66kV and below. It is designed for direct installation in switchgear, combining protection, measurement, fault recording, communication and local status display in one device.
A dual-channel temperature and humidity sensing system provides cabinet environmental monitoring, while the 5-inch color LCD gives on-site personnel direct access to measurements, alarms and protection information. Typical applications include incoming and outgoing feeders, station-service transformers, motors and capacitor circuits.
The NR-660A belongs to NAHO's broader relay protection product family. Related models cover dual-incoming protection and automatic transfer (NR-661A), section-switch protection and automatic transfer (NR-662A), and PT cabinet monitoring/paralleling (NR-663A).
NAHO has been engaged in power automation and microcomputer-based protection since 1992, with project references covering 110kV, 66kV, 35kV and 10kV applications.

Protection, Measurement, Monitoring and Communication
Protection Functions
Three-stage overcurrent with directional lockout (complex-voltage lockout), inverse time-limit overcurrent, overload alarm/trip, three-stage zero-sequence overcurrent, inverse time-limit zero-sequence overcurrent, negative-sequence overcurrent, post-acceleration, reclosing, non-electric quantity protection, over-voltage and low-voltage protection (alarm/trip), zero-sequence overvoltage protection, and bus insulation monitoring.
Measurement
3-phase current + I0 protection/measurement channel; 3-phase voltage + U0 measurement channel.
Communication
RS-485 plus Ethernet, with Modbus, IEC 60870-5-101 and IEC 60870-5-103 protocol support for mixing into existing SCADA or automation networks.
Monitoring
12-way customizable digital input; 6-to-13-way customizable dry-contact digital output; self-checks on the operating circuit, PT disconnection and CT disconnection; fault recording; the dual temperature/humidity sensing described above; and the 5-inch color display that ties it all together.
Model Lineup
|
Model |
Role |
|
NR-660A |
Incoming/feeder cabinet protection |
|
NR-661A |
Dual-incoming protection & automatic switching |
|
NR-662A |
Section-switch protection & automatic switching |
|
NR-663A |
PT cabinet monitoring & paralleling of two PT groups |
Technical Specifications
|
Parameter |
Specification |
|
Applicable Scope |
Small-current grounding system, 66kV and below; incoming, outgoing, station-service transformer, motor and capacitor circuits |
|
Rated Voltage |
100V |
|
Rated Frequency |
50Hz |
|
Rated Current |
5A or 1A (customizable) |
|
Auxiliary Power Supply |
AC/DC 85V–265V; DC 48V |
|
Current Channel |
3-phase + I0 |
|
Voltage Channel |
3-phase + U0 |
|
Digital Input |
12-way, customizable |
|
Digital Output |
6–13-way dry contacts, customizable |
|
Communication Port |
RS-485 / Ethernet |
|
Communication Protocol |
Modbus / 101 / 103 |
|
Display |
4.3-inch color LCD |
|
Environmental Monitoring |
Dual-channel temperature & humidity sensors |
|
Operating Temperature |
-30℃ to +55℃ |
|
Relative Humidity |
≤95%, non-condensing |
|
Atmospheric Pressure |
80–110kPa |
|
Test Standard Condition |
15℃–35℃, 45%–75% RH, 86–106kPa |
|
Dimensions |
149mm(W) × 188mm(H) × 108mm(D); cutout 140mm × 160mm |
|
Compliance |
IEC-TC95 international standard test; KETOP Laboratory type test |
Where It Gets Installed
The NR-660A is suitable for 66kV-and-below switchgear and distribution applications, including:
-

Mining And Industrial Plants
Feeder and distribution protection for mining, metallurgy, chemical and other industrial facilities.
-

Substations And Distribution Rooms
Incoming, outgoing and station-service circuits where local protection information and communication with a station automation system are required.
Transformers, Motors And Capacitor Circuits
General-purpose protection for common plant auxiliary and distribution loads.
-

Related Switchgear Functions
NR-661A, NR-662A and NR-663A can be selected for dual-incoming, section-switch and PT-related applications.
NAHO's wider project experience includes mining, metallurgy, chemical, transportation and power applications. Specific project references are listed below.
Manufacturing, Testing & Customization

NAHO follows a multi-step production and inspection process for its protection-relay products. The process includes SMT placement with AOI inspection, through-hole insertion, wave soldering, visual inspection and a second AOI check, followed by programming and assembly.
After initial adjustment, products undergo 72-hour aging with 24V/48V/220V power supply conditions, together with component-life, withstand-voltage and short-circuit checks. Final inspection includes manual re-adjustment and checks of the panel, rear cover, screws, printed markings, time synchronization and lens condition before packing and shipment.
For project orders, NAHO supports customization of rated current, digital I/O and other configuration requirements. Larger-volume orders can also be discussed for enclosure or appearance customization. OEM/ODM, project integration, technical support and after-sales service are available.
Ordering, Logistics & After-Sales
- MOQ: the NR-660A series ships from 10 units per order; larger volumes support additional appearance/enclosure customization, since tooling costs are amortized across quantity.
- Trade terms & payment: standard international terms (e.g., T/T, L/C) are available and confirmed at quotation stage based on order size and destination.
- Lead time & shipping: production follows the process above, including a mandatory 72-hour burn-in, so lead time is quoted per order volume; shipment departs from NAHO's Zhejiang facility by sea or air freight as required.
- Packaging: units go through final inspection and are packed to withstand export shipping before the second warehousing step and dispatch.
- Warranty & after-sales: standard 2-year warranty from date of arrival, backed by OEM/ODM customization, project integration, technical support and after-sales service.

Certifications & Standards




NAHO's protection products have undergone type testing by the National Relay Protection and Automation Equipment Quality Inspection Center (KETOP Laboratory) and IEC-TC95 international-standard testing.
The company has participated in drafting several national and energy-industry standards related to relay protection and power automation, including:
- National standard requirements for standardized relay protection devices at 35kV and below
- NB/T11054-2023, Technical Specification for Anti-Islanding Protection Devices
- NB/T11483-2024, Technical Specification for Relay Protection of AC Power Supply Systems for Urban Rail Transit
- NB/T11480-2024, Technical Specification for Environmental Control Systems for Outdoor Control Cabinets of Smart Substations
NAHO was accepted as a qualified State Grid supplier in 2018 and has more than 70 patents and software copyrights.
Selected Project References

NAHO's project reference list covers multiple voltage levels and application sectors. Selected examples include:
- Jilin Haigou Gold Mine - 66kV distribution-room renovation
- Liaoning Anshan Datonghu Industrial Zone - 66kV substation renovation
- Liaoning Yingkou Deyuan Carbon Plant - 66kV application
- Shanxi Lanxian Fengda Coking Unit - waste-heat power generation project
- Three Gorges Yunyang Reservoir Area Project
- Haixinsha Square, Guangzhou - power-supply protection for the 16th Asian Games opening ceremony
FAQ
Q1: What applications does the NR-660A relay for feeder protection support?
It is designed for small-current grounding systems rated 66kV and below, including incoming feeders, outgoing feeders, station-service transformers, motors and capacitor circuits.
Q2: What can be configured for a project?
Rated current can be customized as 1A or 5A. Digital inputs are customizable, and digital outputs can be configured from 6 to 13 dry contacts.Customization requirements must be specified before placing the order, as these are hardware customizations that cannot be changed by the customer afterward.
Q3: Can it communicate with an existing SCADA or automation system?
Yes. The relay provides RS-485 and Ethernet and supports Modbus, IEC 60870-5-101 and IEC 60870-5-103.
Q4: Which model should be used for other switchgear functions?
NR-661A is for dual-incoming protection and automatic transfer; NR-662A is for section-switch protection and automatic transfer; NR-663A is for PT cabinet monitoring and two-PT-group paralleling.
Q5: Can you provide engineering documents?
Dimensional drawings, wiring diagrams, technical specifications and pre-shipment test documentation can be provided according to project requirements.
Q6: What information is needed for a quotation?
Please provide the project name and location, system voltage and frequency, application type, required protection functions, communication requirements, quantity and customization requirements.
Q7: What is the warranty period?
The standard warranty is two years from the date of arrival. OEM/ODM, project integration, technical support and after-sales service are also available.
Get a Quote

- Project name & location
- System voltage & frequency
- Application type (incoming / dual-incoming / section switch / PT cabinet / motor / capacitor)
- Required protection functions
- Communication protocol needs (Modbus / 101 / 103)
- Order quantity
- Customization requirements (digital I/O, rated current, enclosure)
Hot Tags: relay for feeder protection nr660a, China relay for feeder protection nr660a manufacturers, suppliers, factory