Feeder Management and Protection Relay NR630

Feeder Management and Protection Relay NR630

One feeder management and protection relay and switching management on 66kV-and-below panels — cutting cabinet count and wiring on incoming, feeder and section-switch bays engineered around your grid code.
Send Inquiry
Description

NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of feeder management and protection relay nr630 in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.

 

Why Combine Protection and Switching in One Box

 

 

4-NH630

 

Panel designers working on 66kV-and-below switchgear usually end up stacking a protection relay next to a separate switching/automation controller - more wiring, more panel depth, more points of failure. The NR-630 folds both jobs into a single microcomputer-based unit: a feeder management and protection relay that also carries automatic reserve-power switching, section-switch auto-transfer and PT paralleling logic, so a distribution system rated 66kV and below gets full incoming, outgoing, station-transformer, motor and capacitor-bank coverage without a second box on the panel. It's built for direct, dispersed mounting, which keeps cable runs short and installation straightforward on retrofit projects as much as new-build ones.

 

The series scales the same way NAHO's other feeder platforms do: NR-631 adds dual-incoming protection with automatic source switching, NR-632 handles section-switch protection with automatic bus transfer, and NR-633 is built specifically for PT cabinets, monitoring and paralleling two voltage-transformer groups. What sets NR-630 apart from lower-voltage feeder relays in NAHO's lineup is the breadth bundled into that one platform - reserve-power switching, section auto-transfer, PT paralleling, motor stall/prolonged-start protection and a full operation-cabinet function - plus local visibility through a color LCD, digital-tube readout and dual-channel temperature/humidity monitoring, all without needing an external HMI.

product-1200-900

 

 

Model Lineup

 

 

Model

Function

NR-630

Protection for incoming and feeder cabinets

NR-631

Dual-incoming power supply protection with automatic switching

NR-632

Section-switch protection with automatic switching

NR-633

PT cabinet monitoring and paralleling of two PT groups

 

 

Protection, Switching, Measurement and Communication

  • product-5712-3213

    Protection

    Three-section overcurrent with directional lockout (complex-voltage lockout); inverse time-limit overcurrent; overload alarm/trip; three-section zero-sequence overcurrent; inverse time-limit zero-sequence overcurrent; negative-sequence overcurrent; post-acceleration; reclosing; over/low-voltage protection (alarm/trip); zero-sequence overvoltage protection (alarm/trip); non-electric quantity protection; motor prolonged start-up protection; stall (locked-rotor) protection.

  • product-5712-4284

    Measurement

    • 3-phase + I0 current protection/measurement channel; 3-phase + U0 voltage measurement channel.

     

    Communication

    • RS-485 and Ethernet ports; Modbus, IEC 60870-5-101 and IEC 60870-5-103 protocol support.
  • product-1265-949

    Switching Management & Monitoring - The Part That Sets This Feeder Management And Protection Relay Apart From A Protection-Only Device

    12-way customizable digital input; 12-way dry-contact digital output; bus insulation monitoring; PT and CT disconnection self-checks; PT paralleling; automatic switching and auto-recovery of reserve power; section-switch automatic transfer; voltage phase-reversal detection; operating-circuit self-check; fault recording; dual-channel temperature/humidity monitoring; digital-tube meter display / 4.3" color LCD; operation-cabinet function.

This full function set belongs to the base NR-630; the NR-631/632/633 share the same protection and communication core, with dual-incoming switching, section-switch transfer, or PT-paralleling logic switched on according to model.

 

 

Technical Specifications

 

Parameter

Specification

Applicable Scope

66kV and below; incoming, outgoing, station-transformer, motor and capacitor cabinets; direct dispersed installation on switchgear

Rated Voltage

100V

Rated Frequency

50Hz

Rated Current

5A or 1A (customized)

Auxiliary Power Supply

AC/DC 85V–265V; DC 48V

Current Channel

3-phase + I0

Voltage Channel

3-phase + U0

Digital Input

12-way, customizable

Digital Output

12 dry contacts

Communication Port

RS-485 / Ethernet

Communication Protocol

Modbus / 101 / 103

Operating Temperature

-30℃ to +55℃

Relative Humidity

≤95%, non-condensing

Atmospheric Pressure

80–110kPa

Test Standard Condition

15℃–35℃, 45%–75% RH, 86–106kPa

Dimensions (NR-630)

175mm(W) × 185mm(H) × 108mm(D); cutout 175mm × 182mm

Compliance

KETOP Laboratory type test; IEC-TC95 international standard testing

 

IP rating to be confirmed and added once available.

 

Panel Scenarios

 

modular-1
  • Incoming & feeder bays, 66kV and below - the base NR-630 handles standard line protection.
  • Dual-source incoming cabinets - NR-631 switches automatically between two power supplies to protect supply continuity.
modular-2
  • Section-switch / bus-tie cabinets - NR-632 transfers the load through the bus tie automatically during a source outage.
  • PT cabinets - NR-633 monitors and parallels two voltage-transformer groups.
modular-3
  • Station transformers, motors and capacitor banks - general protection across industrial and mining distribution systems, including motor stall and prolonged-start coverage the smaller feeder relays in NAHO's range don't carry.

 

 

From Fault to Switching Decision

 

Current and voltage transformers feed 3-phase + I0/U0 signals into the relay in real time; the onboard microprocessor checks those readings against configured thresholds for overcurrent, zero-sequence, voltage and non-electric-quantity conditions. When it detects a fault or a supply loss, it doesn't just trip - on NR-631/632 it also decides whether the right response is an automatic source switch or a section-switch transfer, issuing that command through its dry-contact outputs and logging the event for post-event review.

 

Manufacturing Behind the NR-630

 

product-1267-1027

NAHO's automation heritage goes back to 1992, and every NR-630 unit passes through the same production discipline as the rest of the range before it reaches a panel: SMT placement with AOI inspection, manual through-hole assembly, wave soldering with visual and AOI re-check, firmware flashing, full assembly, initial adjustment followed by a 72-hour burn-in at 24V/48V/220V, component-life and withstand-voltage testing, short-circuit verification, final manual re-adjustment, and an appearance/function inspection (panel, back cover, screws, printing, clock timing, lens) ahead of packing. Digital input, rated current, and - for large enough orders - enclosure and appearance can all be adjusted to the project rather than staying fixed to a catalog SKU.

 

That process sits behind 144+ documented engineering deployments from 110kV down to 10kV across 11+ provinces, 70+ patents and software copyrights, and continued participation in drafting national and industry relay-protection standards.

 

Ordering, Logistics & After-Sales

 

  • MOQ: NR-630-series orders start at 10 units; larger volumes open up custom enclosure/appearance work, since tooling costs are only justified at scale.
  • Trade terms & payment: standard international terms (T/T, L/C) are confirmed at quotation based on destination and order size.
  • Lead time: driven mainly by the mandatory 72-hour burn-in and final inspection steps above, quoted per order volume.
  • Shipping & packaging: dispatched from NAHO's Zhejiang facility by sea or air freight; units are boxed for export shipping after final inspection and a second warehousing step.
  • Warranty: two years from the date of arrival at the customer's site, backed by OEM/ODM customization, project integration and after-sales support.
product-900-643

 

 

Certifications & Standards

 

product-1221-1628
product-1268-1711
product-1267-1710
product-1268-1711
  • Type-tested by the National Relay Protection and Automation Equipment Quality Inspection and Testing Center (KETOP Laboratory)
  • Tested to IEC-TC95 international standards
  • Standard-drafting participant for multiple national and industry relay-protection standards
  • Qualified supplier to State Grid Corporation (shortlisted 2018)
  • 70+ patents and software copyrights across NAHO's product range

English-language certificate scans to be confirmed by the company before publication.

 

 

Case Studies / Project References

 

Featured Projects

 

product-1200-675
  • 2010 16th Asian Games opening ceremony power supply protection system, Haixinsha Square
  • Three Gorges Yunyang Reservoir Area project

NR-630 Series Candidate References (voltage/switching configuration inferred from project name only - pending company confirmation before publication)

 

Project

Voltage

Relevance

Kailu Town transition substation, Inner Mongolia

66kV/10kV

Dual-voltage transition substation - candidate reference for NR-631 dual-incoming switching

Yanji District Heating Source Plant step-down distribution project

66kV–6kV

Multi-level distribution project - candidate reference for NR-632 section-switch transfer

Haigou Gold Mine 66kV distribution room renovation, Jilin

66kV

General 66kV feeder protection reference

Datong Bay Industrial Zone 66kV substation renovation, Anshan, Liaoning

66kV

General 66kV feeder protection reference

 

 

FAQ

 

Q1: What does the NR-630 series actually cover?

It's a feeder management and protection relay and switching management for 66kV-and-below switchgear: feeder protection on the base NR-630, dual-incoming auto-switching on NR-631, section-switch auto-transfer on NR-632, and PT monitoring/paralleling on NR-633 - all sharing one protection and communication core.

Q2: What's different about NR-630 compared to a plain feeder relay?

It bundles switching automation (reserve-power switching, section-switch transfer, PT paralleling) and motor-specific protection (stall, prolonged start) into the same box as core feeder protection, so fewer separate devices are needed on the panel.

Q3: Does NR-631 switch between two power sources automatically?

Yes - it monitors both incoming supplies and performs automatic switching and auto-recovery if the primary source is lost.

Q4: Does NR-632 handle automatic section-switch transfer?

Yes - on detecting a source fault or outage it transfers the load through the section switch automatically to maintain continuity.

Q5: Can digital I/O or rated current be customized?

Yes - digital I/O and rated current (5A or 1A, depending on your CT configuration) can be customized. Please specify your requirements when ordering, as these are hardware-customized and cannot be changed by the customer after delivery.

Q6: What's the minimum order quantity and typical lead time?

MOQ is 10 units for this series; lead time depends on order volume, largely driven by the 72-hour burn-in built into production.

Q7: What's the warranty?

Two years from the date of arrival at the customer's site.

Q8: Do you provide OEM/ODM customization?

Yes - full OEM/ODM customization, project integration, technical support and after-sales service are available.

Q9: What information speeds up a quote or model selection?

Project location, system voltage and frequency, application type, required protection and switching functions, communication protocol needs, quantity, and any customization requirements.

Q10: Can you supply technical drawings and pre-shipment testing evidence?

Yes - dimensional drawings, wiring diagrams and pre-shipment testing support are available on request.

 

Get a Quote

 

product-1269-952
  • Project name & location
  • System voltage & frequency
  • Application type (incoming / dual-incoming / section switch / PT cabinet / motor / capacitor)
  • Required protection functions
  • Communication protocol needs (Modbus / 101 / 103)
  • Order quantity
  • Customization requirements (digital I/O, rated current, enclosure)

 

Request a Quote

 

Hot Tags: feeder management and protection relay nr630, China feeder management and protection relay nr630 manufacturers, suppliers, factory