NAHO Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of numerical motor protection and control relay nr-500m in China. With a professional team, we are committed to providing high quality customized service and OEM&ODM service for global customers. Please rest assured to wholesale bulk premium products at competitive price from our factory. Also, quotation is available.
NR-500M Numerical Motor Protection and Control Relay for Large and Medium Motors

What the NR-500M Is
A big motor drives the costliest process on a site, so the relay monitoring it must do far more than react to a current spike. The NR-500M merges protective elements, sampling channels and breaker control for motors on systems up to 110kV. It can be mounted in a central relay room or on site inside the switchgear, and it exchanges data smoothly with the integrated automation platforms of substations and distribution stations.
Its duty follows the machine. Beside a large motor it serves as the backup guard; for a small or medium motor it is the primary guard. Where a large motor needs primary differential protection, NAHO offers the sister device NR-500MD, a numerical motor differential protection unit from the same range.
Production happens under our roof in Yueqing, Zhejiang. Boards run through SMT lines with AOI checks, and each relay undergoes a 72-hour powered burn-in before dispatch.
NR-500M or NR-500MD: Pick by Role
State the job the relay performs in your scheme.
- Backup for a large motor, or primary guard for a small or medium motor: NR-500M.
-
Primary guard for a large motor, where a differential scheme is wanted: NR-500MD.
Some projects install two units, one as the primary device and one as the backup, giving every feeder two layers of cover.

Feature Overview
-

Protective elements
- Instantaneous (quick-break) current stage
-
Locked rotor
-
Thermal overload, which follows winding heat build-up
-
Overload with alarm or trip selectable
-
Negative-sequence overcurrent, two stages, definite or inverse timing
-
Overvoltage, low-voltage and zero-sequence overvoltage
-
Non-electrical quantity inputs
-

Sampling channels
- Three protection currents, three metering currents and I0, each on its own channel
-
Three-phase voltage plus U0
Control and supervision
- Integrated operation box with trip/close self-holding and anti-pumping
-
Wire-break self-checks for PT and CT circuits, plus an operating circuit self-check
-
Fault recording as standard
-
16 digital inputs, 14 digital outputs
-

Communication
-
One RS-485 port as standard
-
Alternate arrangement: two RS-485 ports and two Ethernet ports
-
What Self-Holding, Anti-Pumping and Thermal Overload Mean
Self-holding retains a trip or close command until the breaker has really changed position, so a short pulse cannot leave the breaker half-way. Anti-pumping stops the breaker from repeatedly closing onto a fault when a close command is kept on by an attendant or a stuck contact. Thermal overload follows accumulated heating of the windings instead of a single current reading, so a motor that has just been through several heavy starts is judged on its real thermal state. Negative-sequence overcurrent reveals unbalance and broken-conductor conditions that a plain phase element may miss; definite timing gives a fixed delay, while inverse timing shortens the delay as the current rises.
Technical Parameters
| Ratings |
100V rated voltage (400V customized), 50Hz, current 5A or 1A on request. Supply choices: AC/DC 110V, AC/DC 220V or DC 48V. |
| Terminals |
16 binary inputs, 14 binary outputs, RS-485 with Ethernet as an add-on. |
| Climate |
-30℃ to +55℃, up to 95% humidity without condensation, 80 to 110kPa. Reference test air conditions: 15℃ to 35℃, 45% to 75% RH, 86 to 106kPa. The air should contain no acid, alkaline, corrosive or explosive matter, and the site needs shelter from lightning, rain and snow. |
| Case |
front panel 156mm × 232mm; overall depth 198mm, main body 171mm. Panel opening 138mm × 212mm. |
| Mounting |
central relay panel or on-site switchgear. |
| Testing |
KETOP Laboratory type test and IEC-TC95 international standard testing. |
Where It Is Installed
Substations and distribution stations, tied into integrated automation.
Power plants and hydropower stations, on auxiliary loads such as pump and fan motors.
Metallurgy, petroleum, chemical, textile, paper, machine building and mining, in relay panels or in the switchgear itself.
Environmental and transport projects, including water and wastewater treatment plants.
From Signal to Breaker
The relay first digitizes phase currents, I0, phase voltages and U0, while scanning its inputs for contact and non-electrical signals. A microprocessor executes the enabled elements, from instantaneous current and locked rotor to thermal load, overload, unbalance and voltage conditions, and tracks start-up and running status of the motor. Once a setting is passed, the fault type is identified and your alarm-or-trip choice applied. The operation box then executes the command with self-holding and anti-pumping, the waveform is retained, and records travel to SCADA over the communication ports.
Built for Your Project

NAHO builds the product it sells. Our origins extend to 1992, with more than thirty years devoted to power automation and customized solutions on 144+ projects from 110kV down to 10kV across more than eleven provinces, plus distributed PV plants of up to 10.96606 MW.
What can be tailored on the NR-500M:
- Rated voltage: 100V standard, 400V customized.
- Rated current: 5A or 1A according to your current transformers.
- I/O arrangement and operation box variants.
- Custom enclosure design for large volumes, since tooling needs sufficient quantity to pay back.
- OEM/ODM, project integration, technical support and after-sales service.
Since such choices are built into the device circuitry, write them into the order remarks before production; the user cannot change them later.
-
Production route: SMT placement with AOI, operator insertion, wave soldering with re-inspection, firmware loading and unit build-up, preliminary tuning, 72-hour powered aging, component life check, withstand-voltage and short-circuit tests, outgoing inspection, dispatch.
-
Ordering essentials: MOQ 10 units for NR-500M series devices. Warranty 2 years starting when the goods arrive.
Approvals and Standards




Every NAHO product is type-tested by the KETOP Laboratory, the national relay protection and automation equipment quality inspection and testing center, and has cleared IEC-TC95 testing. We helped draft the national standard on general technical requirements for standardized relay protection devices of 35kV and below (2019, 2021), plus NB/T 11054-2023 (anti-islanding protection devices), NB/T 11483-2024 (relay protection for urban rail transit AC power supply) and NB/T 11480-2024 (environmental control of smart substation outdoor control cabinets). Also on record: State Grid qualified supplier since 2018, National High-tech Enterprise, national Little Giant enterprise (2023), 70+ patents and software copyrights, and membership of the relay protection and automation branch of the China Electrical Equipment Industry Association since 2006.
Reference Work

These are company-level references from NAHO substation and distribution engineering; they are not specific to motor relays.
- Flagship jobs: the Haixinsha Square opening ceremony venue of the 16th Asian Games (2010), and the Three Gorges Yunyang reservoir area.
- Metals: Anhui Shengxin Aluminum distribution works and Liaocheng Weisidel Aluminum (35kV).
-
Materials and mining: a Liaoning carbon plant (66kV), Gansu Chunlong Mining substation (35kV).
-
Heat and power: Shanxi Lanxian Fengda coking plant waste-heat power scheme (66kV).
Questions Engineers Ask
Q1: Why use a numerical motor protection and control relay instead of separate devices?
Protection, metering, breaker operation, self-supervision and fault recording share one unit and one communication link, which reduces wiring and panel space.
Q2: Can the NR-500M guard a large motor alone?
As backup, yes. For primary protection of a large motor, add the NR-500MD differential device.
Q3: Which protective elements are built in?
Instantaneous current, locked rotor, thermal overload, overload, two-stage negative-sequence overcurrent, over/low-voltage, zero-sequence overvoltage and non-electrical quantity inputs, with PT, CT and operating circuit checks and fault recording.
Q4: What can I specify before ordering?
Rated voltage (100V or 400V), rated current (5A or 1A), digital I/O layout and operation box options.
Q5: How many communication ports are offered?
One RS-485 port as standard, or an alternative with two RS-485 and two Ethernet ports; tell us your needs when requesting a quote.
Q6: Minimum order and warranty?
10 units; two years from arrival.
Q7: Do you offer OEM/ODM and custom enclosures?
Yes, with custom enclosures for large-volume orders, plus project integration, technical support and after-sales service.
Get a Quote

Send our engineers your project name and location, system voltage and frequency, application (substation, hydropower, industrial, mining or other), motor data and required protection, communication needs, quantity (MOQ 10 units) and customization wishes for voltage, current, I/O, operation box or enclosure. A price offer for the numerical motor protection and control relay follows within 24 hours.
Hot Tags: numerical motor protection and control relay nr-500m, China numerical motor protection and control relay nr-500m manufacturers, suppliers, factory